Sun Fire X4150 Server Service Manual
For 1U Systems
820-1852-13
Contents |
1. Sun Fire X4150 Server Overview
1.2 Sun Fire X4150 Server Chassis Overview
1.3 Sun Fire X4150 Server Front Panel Features
1.4 Sun Fire X4150 Server Rear Panel Features
1.5 Illustrated Parts Breakdown
2. Preparing to Service the System
2.3 Obtaining the Chassis Serial Number
2.4.1 Powering Off the Server Using the Service Processor Command Line
2.5 Extending the Server to the Maintenance Position
2.6 Removing a Server From the Rack
2.7 Performing Electrostatic Discharge and Antistatic Prevention Measures
2.7.1 Electrostatic Discharge Safety Measures
2.7.1.1 Using an Antistatic Wrist Strap
2.7.1.2 Using an Antistatic Mat
3. Servicing Customer Replaceable Devices
3.1 Hot-Pluggable or Hot-Swappable Devices
3.2.1 Sun Fire X4150 Server Drive Guidelines
3.2.2 Sun Fire X4150 Server SSD Guidelines
3.2.2.1 SSD Minimum Required Firmware
3.2.3 Drive Status LED Reference
3.2.4 Removing a Hard Drive or SSD
3.2.5 Installing an Hard Drive or SSD
3.3.1 About Sun Fire X4150 Server Fans
3.3.2 Fan Module LED Reference
3.3.3 Detecting Fan Module Failure
3.4.1 Detecting Power Supply Failure
3.4.2 Power Supply LED Reference
3.4.4 Installing a Power Supply
3.5 Servicing the DVD/USB Module
3.5.1 Removing the DVD/USB Module
3.5.2 Installing the DVD/USB Module
4. Servicing Motherboard Components
To Install Additional FB-DIMMs
4.4.1 Sun Fire X4150 Server PCIe Card Guidelines
4.6 Servicing the Motherboard Assembly
To Remove the Motherboard Assembly
4.6.1 To Install the Motherboard Assembly
To Install an XOption Processor
4.8 Resetting Passwords and Clearing CMOS NVRAM
To Reset a Service Processor Password From the BIOS Screen
To Reset a BIOS Password Using a Jumper
To Reset CMOS NVRAM Using a Jumper
4.9 Recovering from Corrupt Service Processor Software
5. Servicing Infrastructure Boards and Components
5.1 Servicing the Fan Power Boards
5.1.1 Removing a Fan Power Board
5.1.2 Installing a Fan Power Board
5.2.1 Removing the Drives Cage
5.2.2 Installing the Drives Cage
5.3 Servicing the Drives Backplane
5.3.1 Removing the Drives Backplane
5.3.2 Installing the Drives Backplane
5.4 Servicing the Front Control Panel Light Pipe Assembly
5.4.1 Removing the Front Control Panel Light Pipe Assembly
5.4.2 Installing the Front Control Panel Light Pipe Assembly
5.5 Servicing the Power Distribution Board (PDB)
5.5.1 Removing the Power Distribution Board
5.5.2 Installing the Power Distribution Board
5.6.1 Removing the Paddle Card
5.6.2 Installing the Paddle Card
5.7.1 Removing Drive Cables in a SAS Configuration
5.7.2 Installing Drives Cables in a SAS Configuration
5.7.3 Removing Drive Cables in a SATA Configuration
5.7.4 Installing Drive Cables in a SATA Configuration
5.7.5 Changing Drive Cables from SAS to SATA
5.7.6 Change Drive Cables from SATA to SAS
5.7.7 Converting From SAS Configuration To SSD Configuration
6. Returning the Server to Operation
6.2 Reinstalling the Server in the Rack
6.3 Returning the Server to the Normal Rack Position
A.1 Serial Management Port Connector
A.2 Network Management Port Connector
A.5 Gigabit Ethernet Connectors
B. BIOS Power-On Self-Test (POST) Codes
B.2 How BIOS POST Memory Testing Works
B.3 Redirecting Console Output
C.1.2 BIOS Setup Screens Overview
C.2.2 BIOS Advanced Menu Screens
C.2.4 BIOS Server Menu Screens
C.2.5 BIOS Security Menu Screens
Copyright © 2009 Sun Microsystems, Inc. All rights reserved.