Sun Ultra 45 and Ultra 25 Workstations Service and Diagnostics Manual
|
|
This appendix discusses the various specifications of the Sun Ultra 45 or Ultra 25 workstation. Topics covered are:
B.1 Physical Specifications
The physical specifications of the Sun Ultra 45 or Ultra 25 workstation are shown in TABLE B-1, FIGURE B-1, and FIGURE B-2.
TABLE B-1 Exterior Dimensions
Length
|
Width
|
Height
|
Weight
|
22.407 in.
569.15 mm
|
8.07 in.
205 mm
|
17.520 in.
445 mm
|
50 - 58 lbs
22.67 - 26.30 kgs
|
If the Sun Ultra 45 or Ultra 25 workstation is placed in an enclosure, be sure to allow adequate airflow from front to rear.
FIGURE B-1 Workstation Dimensions With Stabilizer Open
FIGURE B-2 Workstation Dimensions Without Stabilizer
B.2 Electrical Specifications
TABLE B-2 lists electrical specifications for the Sun Ultra 45 or Ultra 25 workstation.
TABLE B-2 Electrical Specifications
Maximum AC Input
|
Voltage
|
Current
|
Frequency
|
Range 1
|
100 VAC
|
12 amps
|
50 - 60 Hz
|
Range 2
|
110 - 127 VAC
|
10 amps
|
50 - 60 Hz
|
Range 3
|
200 - 240 VAC
|
6 amps
|
50 - 60 Hz
|
TABLE B-3 lists the power supply specifications.
TABLE B-3 Power Supply Specifications
Specification
|
Value
|
Input Voltage
|
100 - 127 VAC, 200 - 240 VAC
|
Frequency
|
50 - 60 Hz
|
Current
|
6.4 amps @ 100 VAC, 3.2 Amps at 200 VAC
|
Wattage
|
630 W input (Power supply rated at 1,000 W maximum)
|
B.3 Acoustic Specifications
TABLE B-4 lists acoustic specifications for the Sun Ultra 45 or Ultra 25 workstation.
TABLE B-4 Declared Noise Emissions: ISO 9296
Specification
|
Operating
|
Idling
|
LWAd (1B=10db)
|
5.0 B
|
4.5 B
|
LpAm (by standard position)
|
42 dBA
|
38 dBA
|
B.4 Environmental Requirements
TABLE B-5 lists environmental requirements for the Sun Ultra 45 or Ultra 25 workstation.
TABLE B-5 Environmental Requirements
Specification
|
Operating
|
Nonoperating
|
Temperature
|
32 F to 104° F (0 C to 40° C)
|
-40 to 158° F (-40 C to 70 C)
|
Humidity
|
10% to 90% RH noncondensing, 27 C max wet bulb
|
93% RH noncondensing
|
Altitude
|
10,000 ft (~3 km)
|
40,000 ft (~12 km)
|
B.5 Shock and Vibration Specifications
TABLE B-6 lists vibration specifications for the Sun Ultra 45 or Ultra 25 workstation.
TABLE B-6 Shock and Vibration Values
Constraint
|
Operating
|
Nonoperating
|
Shock
|
5 G's, 11 msec, half-sine
|
30 G's, 11 msec, half-sine
|
Vibration
|
0.2 G's, 5 to 500 Hz swept-sine
|
1.0 G's, 5 to 500 Hz swept-sine
|
Handling Drop
|
N/A
|
100 mm
|
Sun Ultra 45 and Ultra 25 Workstations Service and Diagnostics Manual
|
819-1892
|
|
Copyright © 2006, Sun Microsystems, Inc. All Rights Reserved.