C H A P T E R  2

Sun Fire X4450 Server ILOM 2.0 Supplement

This supplement provides platform-specific information related to ILOM 2.0 running on a Sun Fire X4450 server.

The following topics are covered in this supplement:


ILOM 2.0 Features Supported

The Sun Fire X4450 server supports the entire ILOM 2.0 feature set except for the delayed BIOS upgrade.

Picture of Sun Fire X4250 front panel showing the location of the Locator button.


Sensors Reference Information

The server includes a number of sensors that generate entries in the system event log (SEL) when they cross a threshold. Many of the sensor readings are used to adjust the fan speeds and perform other actions, such as illuminating LEDs and powering off the server.

This section describes the following sensors:

Power Supply Sensors

lists the power supply sensors.

The system normally has two power supply modules, PS0 and PS1. All sensors are located under /SYS/PSn except for /SYS/VPS.

For example, /SYS/PS0/PRSNT is the power supply 0 presence indicator.


TABLE 2-1 Power Supply Sensors

Sensor Name

Description

/SYS/VPS

Power supply output (watts).

  • upper_nonrecov_threshold - 1350 Watts
  • upper_critical_threshold - 1220 Watts
  • upper_noncritical_threshold - 1080 Watts

PSn/PRSNT

Power supply 0 or 1, present or not present.

PSn/VINOK

Asserted when input voltage is OK.

PSn/PWROK

Asserted when power level is OK.

PSn/V_IN

Input voltage level.

  • upper_nonrecov_threshold - 280.00 Volts
  • upper_critical_threshold - 270.00 Volts
  • upper_noncritical_threshold - 260.00 Volts
  • lower_noncritical_threshold - 90.00 Volts
  • lower_critical_threshold - 80.00 Volts
  • lower_nonrecov_threshold - 70.00 Volts

PSn/I_IN

Input current (amps).

PS0/V_OUT

Output voltage level.

  • upper_nonrecov_threshold - 16.00 Volts
  • upper_critical_threshold - 14.96 Volts
  • upper_noncritical_threshold - 14.00 Volts
  • lower_noncritical_threshold - 10.00 Volts
  • lower_critical_threshold - 8.96 Volts
  • lower_nonrecov_threshold - 8.00 Volts

PSn/I_OUT

Output current (amps).

PSn/IN_POWER

Input power (watts).

PSn/OUT_POWER

Output power (watts).


Temperature Sensors

TABLE 2-2 lists the temperature sensors.

Temperature sensors report on temperature conditions in the motherboard and the chassis.


TABLE 2-2 Temperature Sensors

Sensor Name

Description

ACPI

Power state (ON or OFF)

When asserted, firmware upgrades are not possible.

MB/T_AMBn

Motherboard temperature sensor n (n = 0 through 3).

  • upper_critical_threshold - 65.00 degree C
  • upper_noncritical_threshold - 60.00 degree C

T_AMB

Chassis temperature sensor.

  • upper_nonrecov_threshold - 50.00 degree C
  • upper_critical_threshold - 45.00 degree C

MB/T_DIMMn

DIMMs temperature sensor n (n = 0 through 3).

  • upper_critical_threshold - 95.00 degree C
  • upper_noncritical_threshold - 90.00 degree C

Voltage Sensors

lists the voltage sensors.

Voltage sensors report various voltage levels within the system. Most include upper and lower critical and non-recoverable thresholds.


TABLE 2-3 Voltage Sensors

Sensor Name

Description

MB/V_+12V

12V power supply level.

  • upper_critical_threshold - 13.91 Volts
  • lower_critical_threshold - 10.32 Volts

MB/V_VTT

VTT voltage level.

  • upper_critical_threshold - 1.39 Volts
  • lower_critical_threshold - 1.03 Volts

MB/V_+1V5

1.5V power supply level.

  • upper_critical_threshold - 1.72 Volts
  • lower_critical_threshold - 1.27 Volts

MB/V_+3V3

3V power supply level.

  • upper_critical_threshold - 3.81 Volts
  • lower_critical_threshold - 2.82 Volts

MB/V_+5V

5V power supply level.

  • upper_critical_threshold - 5.94 Volts
  • lower_critical_threshold - 4.40 Volts

MB/V_+3V3STBY

3V standby power level

  • upper_critical_threshold - 3.78 Volts
  • lower_critical_threshold - 2.80 Volts

MB/V_+1V5STBY

5V standby power level.

  • upper_critical_threshold - 1.716 Volts
  • lower_critical_threshold - 1.271 Volts

MB/V_+1V8

1.8V voltage level.

  • upper_critical_threshold - 2.27 Volts
  • lower_critical_threshold - 1.68 Volts

MB/Pn/PRSNT

Processor 0 to 3 present.

MB/Pn/V_VCC

VCC voltage level.

MB/Pn/TCCAT

Number of degrees that the CPU temperature is from the system initiating CPU cooling action.


Fan Sensors

TABLE 2-4 lists the temperature sensors.

Fan sensors report the conditions of the system fans. For all fan sensors:

For example:

FP0/FM1/F0/TACH is the speed for fan board 0, fan module 1, Fan 0.


TABLE 2-4 Fan Sensors

Sensor Name

Description

FBn/PRSNT

Fan board 0 or 1 present.

FBn/FMn/PRSNT

Fan module 0 or 1 present.

FBn/FMn/Fn/TACH

Fan speed for fan 0 or 1.

  • lower_critical_threshold - 2400.00 RPM
  • lower_nonrecov_threshold - 2000.00 RPM

NMI Button Sensor

TABLE 2-5 lists the temperature sensors.

The NMI button sensor reports the presence of the NMI button on the system.


TABLE 2-5 NMI Button Sensors

Sensor Name

Description

NMIBTN

NMI button present.


Disk Drive (HDD) Sensors

TABLE 2-6 lists the temperature sensors.

Disk drive sensors report the presence and state of hard disk drives (HDDs) on the disk backplane (DBP).


TABLE 2-6 Hard Disk Drive (HDD) Sensors

Sensor Name

Description

DBP/PRSNT

Disk backplane is present.

DBP/HDDn/PRSNT

Hard drive (HDD) is present.

DBP/HDDn/STATE

Hard drive (HDD) state.


Fault LEDs

TABLE 2-7 lists the temperature sensors.

Fault LEDs indicate problems with the system. They can cause the front panel LEDs to light.


TABLE 2-7 Fault LEDs.

Sensor Name

Description

PSn/CUR_FAULT

Deasserted when input current level is OK.

PSn/VOLT_FAULT

Deasserted when voltage levels are OK.

PSn/FAN_FAULT

Deasserted when power supply fan is faulty OK.

PSn/TEMP_FAULT

Deasserted when power supply temperature is OK.