Sun Cluster 3.0-3.1 Hardware Administration Manual for Solaris OS

SPARC: Additional Campus Cluster Configuration Examples

While detailing all of the configurations possible in campus clustering is far beyond the scope of this document, the following illustrations depict variations on the configurations previously shown.

The following are three-room examples:

The following are two-room examples:


Note –

Configurations that include Sun StorEdge A5x00 disk arrays have no FC switches. The SE A5x00 arrays can contain long-wave GBICS, and thus do not require the switches.


SPARC: Three-Room Examples

The figures in this section show three-room campus cluster configurations with and without multipathing implementations. Each example configuration follows the campus cluster requirements and design guidelines described in this chapter.


Note –

Configurations include Sun StorEdge A5x00 disk arrays have no FC switches. The SE A5x00 arrays can contain long-wave GBICS, and thus may not require the switches.


Figure 7–5 SPARC: Three-Room Campus Cluster With a Multipathing Solution Implemented

Illustration: The preceding and following contexts describe
the graphic.

Figure 7–6 SPARC: Three-Room Campus Cluster (Sun StorEdge A5x00 as Quorum Device)

Illustration: The preceding and following contexts describe
the graphic.

In Figure 7–6, note the absence of FC switches in Room 3. The storage array connection is made through a Sun StorEdge Dual FC Network Adapter and long-wave GBICs.

SPARC: Two-Room Examples

Figure 7–7 shows a two-room campus cluster that uses partner pairs of storage devices and four FC switches, with a multipathing solution implemented. The four switches are added to the cluster for greater redundancy and potentially better I/O throughput. This configuration could be implemented by using Sun StorEdge T3 partner groups or Sun StorEdge 9910/9960 arrays with Sun StorEdge Traffic Manager software installed.

For information about Traffic Manager software, see the Sun StorEdge Traffic Manager Installation and Configuration Guide at http://www.sun.com/products-n-solutions/hardware/docs/.

Figure 7–7 SPARC: Two-Room Campus Cluster With a Multipathing Solution Implemented

Illustration: The preceding context describes the graphic.

The configuration in Figure 7–8 could be implemented by using Sun StorEdge T3 or T3+ arrays in single-controller configurations, rather than partner groups.

Figure 7–8 SPARC: Two-Room Campus Cluster Without a Multipathing Solution Implemented

Illustration: The preceding context describes the graphic.

Figure 7–9 depicts a two-room campus cluster that uses Sun StorEdge A5x00s. Note the absence of switches.

Figure 7–9 SPARC: Two-Room Configuration (Sun StorEdge A5x00s)

Illustration: The preceding context describes the graphic.