This appendix discusses the various specifications of the Sun Netra T6340 Server Module. Topics covered are:
If you need specifications for the modular system chassis, see the chassis documentation.
A.1 Physical Specifications
FIGURE A-1 Server Module Dimensions
TABLE A-1 Server Module Dimensions
Callout
|
Measurement in Inches (Measurement in Millimeters)
|
1
|
19.56 in. (496.82 mm)
|
2
|
1.75 in. (44.6 mm)
|
3
|
12.88 in. (327.15 mm)
|
The Sun Netra T6340 Server Module may weigh up to 19.8 lbs (9 kg), depending on internal configuration.
A.2 System Environmental Specifications
TABLE A-2 includes the environmental requirements that are specific to the Sun Netra T6340 Server Module.
TABLE A-2 Sun Netra T6340 Environmental Requirements
Condition
|
Requirement
|
Operating temperature
|
5˚C to 45˚C (41˚F to 113˚F)
|
Short-term operating temperature
|
-5˚C to 55˚C (23˚F to 131˚F)
|
Nonoperating temperature
|
-40˚C to 70˚C (-40˚F to 158˚F)
|
Optimum operating temperature
|
22˚C (71.6˚F)
|
Operating relative humidity
|
5% to 85% noncondensing
(not to exceed 0.024 kg water per kg of dry air)
|
Short-term operating relative humidity
|
5% to 90% noncondensing
(not to exceed 0.024 kg water per kg of dry air)
|
Nonoperating relative humidity
|
Up to 93% noncondensing
|
Maximum operating altitude
|
1800m (6000 ft) above sea level
at aisle-ambient temperature of 45˚C
|
Maximum nonoperating altitude
|
12,000m (39,370 ft) above sea level
|
A.3 Motherboard Block Diagram
FIGURE A-2 Motherboard Block Diagram
Sun Netra T6340 Server Module Service Manual
|