C H A P T E R  1

Sun StorEdge 3000 Family FRUs

This document provides instructions for removing and installing field-replaceable units (FRUs) in Sun StorEdgetrademark 3120 SCSI arrays, Sun StorEdge 3310 SCSI arrays, Sun StorEdge 3320 SCSI arrays, Sun StorEdge 3510 FC arrays, and Sun StorEdge 3511 SATA arrays.



Note - FRU installation procedures for Sun StorEdge 3510 FC and Sun StorEdge 3511 SATA arrays are identical except where differences are identified in this manual.



Instructions are also included for FRUs which are common to all five arrays. FRU components can be replaced by customers or by Sun service representatives.

This chapter covers the following topics:

Removal and installation instructions are provided for the following FRUs:


1.1 Available FRUs

Most FRUs are hot-swappable. Hot-swappable means that a live upgrade can be performed--the FRU can be removed and replaced while the RAID array is powered on and operational.



caution icon

Caution - Follow the FRU procedures carefully to ensure successful FRU replacement.
When installing a controller module, make sure that the module is installed first and the cables are connected last.



The following tables list the FRUs that are currently available. For additional FRUs and X-options, consult your sales representative or the latest Release Notes for Sun StorEdge 3000 Family products on Sun web sites.

TABLE 1-1 List of Available FRUs for the Sun StorEdge 3120 SCSI Array

FRU Model Number

Description

F370-6195

1U JBOD chassis + I/O board with SAF-TE

F371-0537

1U JBOD chassis + I/O board with SAF-TE, ROHS

F540-6055

Drive module, 36-GB LVD, 15K RPM

F540-6447

Drive module, 36-GB LVD, 15K RPM, ROHS

F540-6056

Drive module, 73-GB LVD, 10K RPM

F540-6448

Drive module, 73-GB LVD, 10K RPM, ROHS

F540-6057

Drive module, 73-GB LVD, 15K RPM

F540-6449

Drive module, 73-GB LVD, 15K RPM, ROHS

F540-6058

Drive module, 146-GB LVD, 10K RPM

F540-6450

Drive module, 146-GB LVD, 10K RPM, ROHS

F540-6494

Drive module, 146-GB LVD, 15K RPM, ROHS

F540-6366

Drive module, 300-GB LVD, 10K RPM

F540-6132

Drive module, 300-GB LVD, 10K RPM, ROHS

F370-6193

AC power supply and fan module, 1U

F371-0536

AC power supply and fan module, 1U, ROHS

F370-6192

DC power supply and fan module, 1U

F371-0535

DC power supply and fan module, 1U, ROHS

F370-5405

Cable, LVD, 1-foot, jumper

F371-0303

Cable, LVD, 1-foot, jumper, ROHS

F370-5528

Cable, LVD, 1.5-foot, expansion

F371-0304

Cable, LVD, 1.5-foot, expansion, ROHS

F370-6630

Cable, DC power

F371-0307

Cable, DC power, ROHS

F370-7590

LED and reset switch module, 1U

F371-0538

LED and reset switch module, 1U, ROHS

XTA-3000-AMBSZ

Air management blank sled, ROHS




caution icon

Caution - You can mix capacity in the same chassis, but not spindle speed revolutions per minute (RPM) on the same SCSI bus. For instance, you can use 36-Gbyte and 73-Gbyte drives with no performance problems if both are 10K RPM drives. Violating this configuration guideline leads to poor performance.



TABLE 1-2 List of Available FRUs for the Sun StorEdge 3310 SCSI Array

FRU Model Number

Description

F370-5393

Box, 2U, JBOD, LVD

F371-0105

Box, 2U, JBOD, LVD, ROHS

F370-5524

Box, 2U, RAID, LVD

F371-0106

Box, 2U, RAID, LVD, ROHS

F370-5394

Event monitoring unit with SAF-TE, 2U

F371-0107

Event monitoring unit with SAF-TE, 2U, ROHS

F370-5396

I/O module, LVD, expansion unit or JBOD, 2U

F370-5397

I/O module, LVD, RAID, 2U

F370-5403

Controller module, LVD, 512 MB memory, battery, 2U

F370-5399

Terminator module, LVD, 2U

F371-0110

Terminator module, LVD, 2U, ROHS

F540-6121

Drive module, 36-GB LVD, 15K RPM

F540-6447

Drive module, 36-GB LVD, 15K RPM, ROHS

F540-5563

Drive module, 73-GB LVD, 10K RPM

F540-6448

Drive module, 73-GB LVD, 10K RPM, ROHS

F540-6097

Drive module, 73-GB LVD, 15K RPM

F540-6449

Drive module, 73-GB LVD, 15K RPM, ROHS

F540-5735

Drive module, 146-GB LVD, 10K RPM

F540-6550

Drive module, 146-GB LVD, 10K RPM, ROHS

F540-6494

Drive module, 146-GB LVD, 15K RPM, ROHS

F540-6366

Drive module, 300-GB LVD, 10K RPM

F540-6132

Drive module, 300-GB LVD, 10K RPM, ROHS

F370-6776

AC power and fan module, 2U

F371-0108

AC power and fan module, 2U, ROHS

F370-6798

DC power and fan module, 2U

F371-0109

DC power and fan module, 2U, ROHS

F370-5533

Battery, LVD

F371-0111

Battery, LVD, ROHS

F370-5405

Cable, LVD, 1-foot, jumper

F371-0303

Cable, LVD, 1-foot, jumper, ROHS

F370-5528

Cable, LVD, 1.5-foot, expansion

F371-0304

Cable, LVD, 1.5-foot, expansion, ROHS

F370-6627

Cable, null modem

F371-0305

Cable, null modem, ROHS

F370-6629

Cable, shielded ethernet

F371-0306

Cable, shielded ethernet, ROHS

F370-6630

Cable, DC power

F371-0307

Cable, DC power, ROHS

F370-7589

LED and reset switch module, 2U

F371-0112

LED and reset switch module, 2U, ROHS

XTA-3000-AMBSZ

Air management blank sled, ROHS


TABLE 1-3 List of Available FRUs for the Sun StorEdge 3320 SCSI Array

FRU Model Number

Description

F371-0105

Box, 2U, JBOD, LVD, ROHS

F371-0106

Box, 2U, RAID, LVD, ROHS

F371-0107

Event monitoring unit with SAF-TE, 2U, ROHS

F370-7713

I/O module, expansion unit or JBOD, 2U, ROHS

F370-7655

I/O module, LVD, RAID, 2U, ROHS

F370-7714

Controller module, 512 MB memory, battery, 2U, ROHS

F371-0110

Terminator module, LVD, 2U, ROHS

F540-6447

Drive module, 36-GB LVD, 15K RPM, ROHS

F540-6448

Drive module, 73-GB LVD, 10K RPM, ROHS

F540-6449

Drive module, 73-GB LVD, 15K RPM, ROHS

F540-6450

Drive module, 146-GB LVD, 10K RPM, ROHS

F540-6494

Drive module, 146-GB LVD, 15K RPM, ROHS

F540-6132

Drive module, 300-GB LVD, 10K RPM, ROHS

F371-0108

AC power and fan module, 2U, ROHS

F371-0109

DC power and fan module, 2U, ROHS

F371-0111

Battery, LVD, ROHS

F371-0303

Cable, LVD, 1-foot, jumper, ROHS

F371-0304

Cable, LVD, 1.5-foot, expansion, ROHS

F371-0305

Cable, null modem, ROHS

F371-0306

Cable, shielded ethernet, ROHS

F371-0307

Cable, DC power, ROHS

F371-0112

LED and reset switch module, 2U, ROHS

XTA-3000-AMBSZ

Air management blank sled, ROHS


TABLE 1-4 List of Available FRUs for the Sun StorEdge 3510 FC Array

FRU Model Number

Description

F370-5535

Box, 2U, FC, chassis + midplane (RAID/JBOD)

F371-0531

Box, 2U, FC, chassis + midplane (RAID/JBOD), ROHS

F370-5537

I/O w/SES and RAID controller FC, 1 GB memory, battery, 2U

F371-0532

I/O w/SES and RAID controller FC, 1 GB memory, battery, 2U, ROHS

F370-5538

I/O w/SES, JBOD FC, 2U

F371-0533

I/O w/SES, JBOD FC, 2U, ROHS

F540-5628

Drive module, 36-GB FC, 15K RPM

F540-5629

Drive module, 73-GB FC, 10K RPM

F540-6570

Drive module, 73-GB FC, 10K RPM, ROHS

F540-6098

Drive module, 73-GB FC, 15K RPM

F540-6571

Drive module, 73-GB FC, 15K RPM, ROHS

F540-5626

Drive module, 146-GB FC, 10K RPM

F541-6572

Drive module, 146-GB FC, 10K RPM, ROHS

F370-6776

AC power supply/fan module, FC/SATA, 2U

F371-0108

AC power supply/fan module, SE3000, 2U, ROHS

F370-6798

DC power supply/fan module, FC/SATA, 2U

F371-0109

DC power supply/fan module, SE3000, 2U, ROHS

F370-6799

Battery module, FC/SATA, 2U

F371-0539

Battery module, FC/SATA, 2U, ROHS

F370-5540

Cable, FC, 1.5-foot, expansion

F371-0534

Cable, FC, 1.5-foot, expansion, ROHS

F370-6627

Cable, null modem

F371-0305

Cable, null modem, ROHS

F370-6629

Cable, shielded ethernet

F371-0306

Cable, shielded ethernet, ROHS

F370-6630

Cable, DC power

F371-0307

Cable, DC power, ROHS

F370-7589

LED and reset switch module, 2U

F371-0112

LED and reset switch module, 2U, ROHS

F370-6188

ID switch module, FC

F371-1967

ID switch module, FC, ROHS

XTA-3000-AMBSZ

Air management sled, ROHS

F371-0294

SFP, 4G, SW 850NM, FC, TRANS, ROHS


TABLE 1-5 List of Available FRUs for the Sun StorEdge 3511 SATA Array

FRU Model Number

Description

F370-6775

Box, 2U, SATA, chassis + backplane (RAID/JBOD)

F370-6773

I/O w/SES and RAID controller SATA, 1 GB memory, battery, 2U

F370-6774

I/O w/SES, JBOD SATA, 2U

F540-6180

Drive module, 250-GB SATA, 7200 RPM

F540-6364

Drive module, 400-GB SATA, 7200 RPM

F540-6365

Drive module, 500-GB SATA, 7K, RPM

F370-6776

AC power supply/fan module, FC/SATA, 2U

F371-0108

AC power supply/fan module, SE3000, 2U, ROHS

F370-6798

DC power supply/fan module, FC/SATA, 2U

F371-0109

DC power supply/fan module, SE3000, 2U, ROHS

F370-6799

Battery module, FC/SATA, 2U

F371-0539

Battery module, FC/SATA, 2U, ROHS

F370-5540

Cable, FC, 1.5-foot, expansion

F371-0534

Cable, FC, 1.5-foot, expansion, ROHS

F370-6627

Cable, null modem

F371-0305

Cable, null modem, ROHS

F370-6629

Cable, shielded ethernet

F371-0306

Cable, shielded ethernet, ROHS

F370-6630

Cable, DC power

F371-0307

Cable, DC power, ROHS

F370-7589

LED and reset switch module, 2U

F371-0112

LED and reset switch module, 2U, ROHS

F370-6188

ID switch module, FC

F371-1967

ID switch module, FC, ROHS

XTA-3000-AMBSZ

Air management sled, ROHS



1.2 Static Electricity Precautions

Perform these steps to prevent damaging the FRUs:


1.3 Power-On Sequence

Power on the equipment in the following order so the host computer discovers all connected arrays:

1. Expansion units

2. RAID controllers

3. Host computers


1.4 Powering Off the Array

Most FRU procedures are hot-swappable except for the chassis replacement procedure, the ID switch module replacement procedure, and the LED module replacement procedure. However, you might need to power off the array (both power supplies) if you relocate the array or perform certain maintenance procedures with its associated servers.



caution icon

Caution - If controllers are not shut down from the firmware application or from the Sun StorEdge Command-Line Interface (CLI) before an array is powered off, data that is written to cache and data that has not been completely written to the disks will be lost.



Before you power off both power supplies, you must perform the following steps, which require shutting down the controller.

1. Stop all I/O activity to the array.

2. Shut down the controller with one of the following commands:

These commands first halt all I/O activity, and then write the contents of cache to the drives.

3. Power off both power supply/fan modules.