C H A P T E R 7 |
Maintaining the Array |
This chapter explains how to maintain the integrity of the array using Array Administration. Topics covered in this chapter are as follows:
Array administration activities such as initialization, drive rebuilding, and
parity checking can take some time, depending on the size of the logical drive or physical drives involved.
After one of these processes has started, the Controller Array Progress window is displayed. If you close the window, to view progress, click the Progress Indicator
icon or choose View Array Admin Progress. You can stop any of these processes at any time by clicking Abort.
To Check Parity |
Parity checking is the process where the integrity of redundant data on fault-tolerant logical drives (RAID 1, 3, and 5) is checked. Depending on which options you select, the parity can be overwritten and any error reported as an event.
1. Select the logical drive on which you want to run parity check.
2. Choose Array Administration Parity Check.
Note - You need to be logged in as either ssadmin or ssconfig to access options on this menu. |
3. When the Logical Drive Parity Check window is displayed, select the logical drive on which you want to run a parity check.
To run a parity check on multiple drives, choose the Array Administration Schedule Parity Check command to schedule a parity check to be run in the near future (such as within three minutes). When scheduled parity check runs, it automatically performs the parity checks one after another.
4. Select from the following options:
Note - If you select Regenerate, make sure that Generate Error Event is also selected so that if inconsistent parity is encountered, bad blocks are specified. |
5. Click the Parity Check button to start the parity check process.
Once a parity check has started, the Progress Indicator is automatically displayed. If this window is closed, it can be reopened by choosing View Array Admin Progress or by clicking the Progress Indicator icon. A window is displayed that shows the percentage of completion progress for each array.
To stop the parity check, click Cancel.
To Schedule a Parity Check |
Choose Array Administration Schedule Parity Check to check parity of a specific logical drive array at scheduled intervals (for example, during off hours).
Note - You need to be logged in as either ssadmin or ssconfig to access options on this menu. |
1. Select the controller on which you want to schedule the parity check.
2. Choose Array Administration Schedule Parity Check.
The Schedule Parity Check window is displayed.
3. Make selections in the appropriate fields on this window.
Note - If you select Regenerate, make sure that Generate Error Event is also selected so that if inconsistent parity is encountered, bad blocks are specified. |
4. When you are satisfied with the schedule, click OK.
To Scan Physical Disks for Bad Blocks (Media Scan) |
The media scan feature sequentially checks each physical drive in a selected logical drive, block by block, for bad blocks. If a bad block is encountered, the controller rebuilds the data from the bad block onto a good block if one is available on the physical drive. If no good blocks are available on the physical drive, the controller designates the physical drive “Bad,” generates an event message, and if a spare drive is available, begins rebuilding data from the bad physical drive onto the spare.
If you have disabled or stopped the automatic continuous media scan, you can start a media scan manually on a logical drive or a single physical drive that makes up a logical drive. It is useful to run a media scan if a drive has failed, if drive errors are encountered, or when a rebuild is required after replacing a drive.
2. Choose Array Administration Media Scan.
After a few moments, the Media Scan window is displayed.
3. To start a media scan on a logical drive, click the Logical Drives tab, and select the logical drive to scan.
To start a media scan on a physical drive that makes up the logical drive, select the Disks tab, and select the physical drive to scan.
4. Select a Media Scan Priority:
5. Select an Iteration Count to specify whether the physical drives are to be checked one time or continuously.
Single time is the default value.
6. Click Run Media Scan, and click OK to continue.
Note - If a media scan is already running, the Run Media Scan button is unavailable. |
7. Click Close on the Starting Array Administration window.
The scan progress is displayed in the Controller Array Progress window.
Depending on the size of the logical drive and the number of physical drives it contains, the scanning process might take some time to complete.
8. When the Controller Array Progress window shows 100% completion, check the event log to determine the condition of the physical disks.
See Event Log for information about viewing the event log.
To Stop a Media Scan on a Logical Drive or Physical Drive |
2. Choose Array Administration Media Scan.
After a few moments, the Media Scan window is displayed.
3. To stop a media scan on a logical drive, click the Logical Drives tab, and select the logical drive on which you want to stop the scan.
To stop a media scan on a physical drive that makes up the logical drive, select the Disks tab, and select the physical drive on which you want to stop the scan.
6. Click Close on the Starting Array Administration window.
Note - To stop a media scan on a physical drive, you can also select Abort for the on the Controller Array Progress window. |
This section contains procedures for recovering from a drive failure with and without a standby drive. If for some reason these procedures do not start the rebuilding process, instructions are also provided for manually starting a rebuild after a drive failure.
To Automatically Rebuild a Drive Using a Standby Drive |
When a drive associated with a fault-tolerant logical drive fails, and a standby drive has previously been installed and configured as either a global or local spare, the failed drive is automatically substituted and its data rebuilt using the designated spare drive. For this to occur flawlessly, the spare drive’s capacity must always be equivalent to or larger than the failed drive that is being replaced.
The rebuilding process normally starts within one to two minutes. It is performed in the background and takes approximately eight minutes per Gbyte when there is no other activity on the controller.
During the automatic rebuild process, normal activity might continue, although performance might degrade. The degree to which performance degrades is determined by the rebuild priority set for the controller. (To change the rebuild priority, see Disk Array Tab.)
The progress of the rebuild process is displayed when you choose View Array Admin Progress.
1. Reestablish automatic rebuild capability by replacing the failed drive, using instructions contained in the Sun StorEdge 3000 Family Installation, Operation, and Service Manual for your array.
2. Wait at least 60 seconds after removing the failed drive before inserting a new drive.
Make sure the replacement drive is at least equal to the largest drive in the enclosure. Install the replacement drive in the same slot (drive bay) as the failed drive; the replacement drive then becomes the new standby drive.
3. After the rebuild process is complete and the logical drive is online again, back up the array controller configuration to a file on an external drive or diskette.
See To Save the Logical Drive Configuration.
To Rebuild a Device Without a Standby Drive |
If there is no standby drive in the array, you need to replace the failed drive before the automatic rebuild process can start.
1. To recover from a drive failure when there is no standby drive, replace the failed drive by using the instructions contained in the Sun StorEdge 3000 Family Installation, Operation, and Service Manual for your array.
2. Wait at least 60 seconds after removing the failed drive before inserting a new drive.
Make sure the capacity of the replacement drive is at least equal to that of the failed drive. Install the replacement drive at the same address (drive bay) as the failed drive.
3. Once the failed drive is replaced in the same slot, you need to scan it in.
For detailed instructions on scanning in a drive, see To Scan in New Hard Drives (SCSI only).
4. After the drive has been scanned, you need to manually rebuild it by choosing Array Administration Rebuild.
To Check the Progress of the Rebuilding Process |
1. Choose View Array Admin Progressor click the Progress Indicator icon in the upper right corner of the window .
The Controller Array Progress window is displayed that shows the completion percentage of the rebuild. However, if there are activities (such as initialization, rebuild, or parity check) occurring on multiple controllers, the Select Controller Progress window is displayed first.
2. Select the controller whose progress you want to view and click OK.
The Controller Array Progress window is displayed that shows the array progress of the selected controller. For more information, see Array Administration Activities.
To Manually Rebuild a Failed Drive |
In most cases, you do not need to use the manual rebuild process because replaced drives are automatically rebuilt.
If a spare is not present when the failure occurs, or for some reason the drive does not rebuild, you can use Rebuild to manually start the rebuild process. Also, if the rebuild process is interrupted by a reset, use Rebuild to restart the rebuilding process.
1. Replace the failed drive, using the instructions contained in the Sun StorEdge 3000 Family Installation, Operation, and Service Manual for your array.
2. Wait at least 60 seconds after removing the failed drive before inserting a new drive.
Make sure the capacity of the replacement drive is at least equal to that of the largest drive in the enclosure.
3. Choose Array Administration Rebuild.
The Rebuild window is displayed.
4. Select the status record of the replacement drive.
5. Click Rebuild to start the rebuild process.
The rebuild process is performed in the background and takes approximately eight minutes per Gbyte when there is no other activity on the array controller. During a rebuild, normal activity can continue, although performance might degrade. The degree to which performance degrades is determined by the rebuild priority set for the controller. (To change the rebuild priority, see Disk Array Tab.)
6. To check the progress of the rebuilding process, choose View Array Admin Progress or click the Progress Indicator icon in the upper right corner of the window.
The Controller Array Progress window is displayed that shows the completion percentage of the rebuild.
If there are array activities (such as initialization, rebuild, or parity check) occurring on multiple controllers, the Select Controller Progress window is displayed first.
7. Select the controller whose progress you want to view and click OK.
The Controller Array Progress window is displayed and shows the array rebuilding status for that controller.
To Restore a Logical Drive Configuration |
This section describes how to restore the array configuration information from a backup file. You must have saved a backup file using the Save command as explained in Configuration File. If the array controller and its drives are damaged, you can restore the array configuration to a new controller without having to completely reconfigure the storage array.
Caution - Restore the array configuration from a file only if the configuration file is current. Data loss will result from restoring an outdated or incorrect configuration. |
If you are sure that the backup file contains the correct array configuration information, continue with the following procedure to restore the configuration.
1. Select the controller for the appropriate array.
2. Choose Configuration Load Configuration.
The Select Configuration File window is displayed.
3. Specify the name and location of the backup configuration file and click Open.
The Load Configuration window is displayed. To see a tree-view representation of the configuration, click the Configuration View tab.
The Saveset Description tab displays the description of the file that was specified when the configuration file was created.
4. (Solaris OS only). If you want the logical drive(s) to be automatically labeled, which enables the OS to use the drive, click Write a new label to the new LD.
5. To load the saved configuration, select OK.
The Load Configuration Confirmation window is displayed.
Carefully review the information presented in the Load Configuration Confirmation window before making a decision to continue.
6. Click Apply to load this configuration or click Cancel to terminate this function.
Apply causes the configuration operation to continue, and a progress window is displayed.
Note - Do not initialize LUN(s) after restoring the array configuration backup file
contents. |
Controller maintenance options include shutting down the controller, muting the controller beeper, bringing a failed controller back online, displaying performance statistics, and determining controller boot time. Downloading firmware options are also included in the Controller Maintenance Options window. For information on downloading firmware, see Updating the Configuration.
To Reset the Controller |
Whenever you make changes to the controller parameters, you are asked if you want to reset the controller so that the changes take effect. If you are making multiple changes, you might not want to stop and reset the controller after each change. Use the Reset the Controller option to manually reset the controller after making multiple parameter changes.
1. Select any storage icon in the main window.
2. Choose Array Administration Controller Maintenance.
3. If you are not already logged in as ssconfig, a password prompt is displayed; type the ssconfig password.
The Controller Maintenance Options window is displayed.
4. Click Reset the Controller.
To Shut Down the Controller |
Whenever the array is powered off, you need to first shut down the controller to ensure that write cache is flushed to disk so that the backup battery (if present) is not drained by the cache memory.
1. Select any storage icon in the main window.
2. Choose Array Administration Controller Maintenance.
3. If you are not already logged in as ssconfig, a password prompt is displayed; type the ssconfig password.
The Controller Maintenance Options window is displayed.
4. Click Shut Down the Controller.
To Mute the Controller Beeper |
When an event occurs that causes the controller to beep, for example, when a logical drive fails, during a rebuild, or when adding a physical drive, you can mute the controller beeper in one of two ways.
1. Select the controller icon in the main window.
2. Choose Array Administration Controller Maintenance.
3. If you are not already logged in as ssconfig, a password prompt is displayed; type the ssconfig password.
The Controller Maintenance Options window is displayed.
4. Click Mute Controller Beeper.
1. Select the desired controller icon in the main window.
2. Choose Configuration Custom Configure.
3. Select Change Controller Parameters.
Note - If the alarm is caused by a failed component, muting the beeper has no effect. You need to push the Reset button on the right ear of the array. See View Enclosure for more information about component failure alarms. |
To Bring a Failed Controller Back Online |
If a controller fails, bring it back online in one of two ways.
1. Select the controller icon in the main window.
2. Choose Array Administration Controller Maintenance.
3. If you are not already logged in as ssconfig, a password prompt is displayed; type the ssconfig password.
The Controller Maintenance Options window is displayed.
4. Click Deassert Failed Redundant Controller.
1. Select the controller icon in the main window.
2. Choose Configuration Custom Configure.
3. Select Change Controller Parameters.
5. From the Set Controller Config field, select Redundant Deassert Reset.
To Display Performance Statistics |
Using Performance Statistics, you can determine the data transfer rate, that is, the speed the array is running at.
1. Choose Array Administration Controller Maintenance.
2. If you are not already logged in as ssconfig, a password prompt is displayed; type the ssconfig password.
The Controller Maintenance Options window is displayed.
3. Click Performance Statistics.
The Performance Statistics window is displayed.
To Get Controller Boot Time |
To provide you with a point of reference when investigating controller events, you can determine when the controller was last powered up or reset.
1. Choose Array Administration Controller Maintenance.
2. If you are not already logged in as ssconfig, a password prompt is displayed; type the ssconfig password.
The Controller Maintenance Options window is displayed.
3. Click Get Controller Boot Time.
The Controller Boot Time window is displayed. The controller date, time, and time zone are set using the firmware application. Refer to the Sun StorEdge 3000 Family RAID Firmware User’s Guide for information about setting the controller date and time.
To Convert a Dual Controller Array to a Single Controller Array |
If one controller fails in a dual array controller configuration, you might want to run a single controller for an extended period of time so that the array does not display as degraded in the console.
1. Make sure you know the serial number of the controller being removed.
You can check the event log for the failed controller’s serial number or check the console and make a note of the primary controller’s serial number.
2. Change the remaining controller’s redundancy setting to disabled.
You must use the firmware application to disable redundancy on the controller. Refer to the Sun StorEdge 3000 Family RAID Firmware User’s Guide for your array for information about accessing the firmware application, and then from the Main Menu, choose “view and edit Peripheral devices Set Peripheral Device Entry Redundant Controller - Primary Disable redundant controller.”
For information about how to stop the agent, see the chapter for your OS in the Sun StorEdge 3000 Family Software Installation Guide.
4. Change to /var/opt/SUNWsscs/ssagent and edit the file sscontlr.txt.
The very last line in the file contains the serial numbers of both controllers. Remove the failed controller’s serial number from this line.
5. Start the agent as explained in the installation chapter for your OS.
6. Rescan the console if it was open during this procedure.
7. In a single-controller configuration, to avoid the possibility of data corruption, disable Write Back Cache.
See Cache Tab for information on disabling Write Back Cache.