Java Desktop System Release 3 User Guide

Configuring PDA Devices on Linux Systems

To access the PDA Devices preference tool, click Launch, then choose Preferences -> Desktop Preferences -> PDA Devices.

A personal digital assistant (PDA) is a hand-held computer that you can use as a personal organizer. You can store appointments, tasks, contacts, and other information on your PDA. You can also transfer this information between your PDA and applications in the Java Desktop System on Linux. For example, you can copy your calendar appointments from your PDA to Email and Calendar, and from Email and Calendar to your PDA.

When you transfer data between your PDA and your computer, you perform a HotSync operation. The actions that occur during a HotSync operation are controlled by conduits. A conduit is an application that manages the transfer of data between your computer and your PDA.

One of the actions that you can specify for a conduit is to merge data between your PDA and your computer. This is called a synchronize action. For example, you might add contact information to your PDA, then add different contact information in Email and Calendar. You want to add the contact information on your PDA to Email and Calendar, and you want to add the contact information in Email and Calendar to your PDA. To do this, you must synchronize the data between your PDA and Email and Calendar.

The PDA Devices preference tool enables you to configure a PDA to work with the Java Desktop System on Linux, and to modify PDAs that you have already configured. You can perform the following tasks with the PDA Devices preference tool:

A background application waits for a PDA to attempt to synchronize with your computer. This background application is called the PDA daemon. When a PDA attempts to synchronize with the computer, the PDA daemon synchronizes the data on the PDA with data on the computer.


Tip –

The PDA Monitor panel application displays the activity of the PDA daemon. To add PDA Monitor to a panel, right-click on the panel, then choose Add to Panel -> Utility -> PDA Monitor. For more information about PDA Monitor, see the online Help for PDA Monitor.


To Configure a PDA

You can configure a PDA in one of the following ways:

To Use an Assistant

Perform the following steps:

  1. Connect your PDA to your computer. If your PDA has a cradle, place the PDA in the cradle.

  2. Click Launch, then choose Preferences -> Desktop Preferences -> PDA Devices to start the PDA Devices preference tool. Click on the Forward button in the assistant to begin the configuration process.

  3. Enter information about how the PDA connects to your computer in the Cradle Settings page. The following table describes the settings in the Cradle Settings page:

    Element 

    Description 

    Name

    Type a name for the connection in the text box.  

    Port

    Enter a port for the connection in the drop-down combination box. For example, if your PDA uses a Universal Serial Bus (USB) port, you might enter /dev/ttyUSB1 in this field. If the PDA does not connect properly, you might need to try another port.

    The default value for the Port field is /dev/pilot. If you do not want to change the default value in this field, you can make a symbolic link from the port that the PDA uses to /dev/pilot. For example, if your PDA uses a USB port, run a command similar to the following command:

    # ln -s /dev/ttyUSB1 /dev/pilot


    Note –

    You must have the appropriate permissions to access the port that you specify. If you do not have the appropriate permissions, contact your system administrator.


    Speed

    Select the speed of the connection from the drop-down list. 


    Tip –

    Select the lowest speed. When you are sure that the connection to the PDA works reliably at the lowest speed, select the next highest speed. Continue to do this until you find the highest speed at which the connection to the PDA works reliably.


    Timeout

    Use the spin box to specify the number of minutes for the connection to be idle before the connection is broken. 

    Type

    Select the type of port from the following options: 

    • Serial: Select this option for a serial port.

    • USB: Select this option for a USB port.

    • IrDA: Select this option for an infrared port.

    • Network: Select this option for a network connection port.

    When you complete the connection information, click on the Forward button. A Pilot Identification page is displayed.

  4. Enter identity information for the PDA in the Pilot Identification page. The following table describes the elements in the Pilot Identification page:

    Element 

    Description 

    Yes, I've used sync software with this pilot before

    Select this option if you have previously set the username and identifier on this PDA. If you configure a PDA with a computer, the username and ID are set on the PDA. 

    No, I've never used sync software with this pilot before

    Select this option if you have not previously set the username and identifier on this PDA. 

    User Name

    If you have not previously set the username and identifier on this PDA, type the username in this text box. 

    ID

    If you have not previously set the username and identifier on this PDA, type the identifier in this text box. This identifier must be unique between different PDAs that you use. 

    When you complete the identity information, click on the Forward button. An Initial Sync page is displayed.

  5. Press the HotSync button on your PDA. Depending on the option you selected on the Pilot Identification page, the Gnome Pilot Settings assistant does one of the following:

    • If you selected the Yes, I've used sync software with this pilot before option, the Gnome Pilot Settings assistant gets the username and identifier that is currently registered on the PDA from the PDA.

    • If you selected the No, I've never used sync software with this pilot before option, the Gnome Pilot Settings assistant sets the username and identifier on the PDA to the values in the User Name text box and ID text box.

    When the initial synchronization is complete, click on the Forward button. A Pilot Attributes page is displayed.

  6. Enter name and directory information for the PDA in the Pilot Attributes page. The following table describes the settings in the Pilot Attributes page:

    Element 

    Description 

    Pilot Name

    Type a name for the PDA. This name identifies the PDA in the user interface. 

    Local basedir

    Enter the directory where you want to store your PDA data. 

    When you complete the name and directory information, click on the Forward button. A Success page is displayed.

  7. Click on the Apply button on the Success page to close the Gnome Pilot Settings assistant.

    Alternatively, click on the Cancel button to cancel the configuration of the PDA.

To Use the PDA Devices Preference Tool

Perform the following steps:

  1. Click Launch, then choose Preferences -> Desktop Preferences -> PDA Devices to start the PDA Devices preference tool.

  2. In the Pilots tabbed section on the Pilot Settings dialog, click Add.

  3. To receive the username and identifier from the PDA, click on the Get from pilot button in the Pilot Settings dialog. To assign a username and identifier to the PDA, type the username and identifier in the text boxes, then click on the Send to pilot button.

  4. Enter name and directory information for the PDA in the Pilot Name and Local basedir fields. For more information about the fields, see To Use an Assistant.

To Modify a PDA

Perform the following steps:

  1. Click Launch, then choose Preferences -> Desktop Preferences -> PDA Devices to start the PDA Devices preference tool.

  2. In the Pilots tabbed section on the Pilot Settings dialog, select the PDA that you want to modify, then click Edit.

  3. To receive the username and identifier from the PDA, click on the Get from pilot button in the Pilot Settings dialog. To assign a username and identifier to the PDA, type the username and identifier in the text boxes, then click on the Send to pilot button.

  4. Enter name and directory information for the PDA in the Pilot Name and Local basedir fields. For more information about the fields, see To Use an Assistant.

  5. Click OK on the Pilot Settings dialog.

To Configure How PDAs Connect

To configure how PDAs connect to your computer, perform the following steps:

  1. Click Launch, then choose Preferences -> Desktop Preferences -> PDA Devices to start the PDA Devices preference tool.

  2. In the Devices tabbed section on the Pilot Settings dialog, click Add.

  3. Enter connection information for the PDA in the Device Settings dialog. For more information about the elements in the Device Settings dialog, see To Use an Assistant.

To Modify How PDAs Connect

To modify how PDAs connect to your computer, perform the following steps:

  1. Click Launch, then choose Preferences -> Desktop Preferences -> PDA Devices to start the PDA Devices preference tool.

  2. In the Devices tabbed section on the Pilot Settings dialog, select the hardware settings that you want to modify, then click Edit.

  3. Enter hardware settings for the PDA in the Device Settings dialog. For more information about the elements in the Device Settings dialog, see To Use an Assistant.

To Specify How to Transfer PDA Data

To specify how to transfer data between your PDA and applications, perform the following steps:

  1. Click Launch, then choose Preferences -> Desktop Preferences -> PDA Devices to start the PDA Devices preference tool.

  2. Ensure that the PDA daemon is active and functions properly. To do this, add the PDA Monitor panel application to a panel. If the PDA Monitor icon appears in black and white, the PDA daemon is active.

  3. In the Conduits tabbed section on the Pilot Settings dialog, use the Pilot Name drop-down list to select the PDA whose conduits you want to configure.

  4. To enable a conduit, select the conduit from the table, then click on the Enable button. Enter configuration details for the conduit in the Conduit Settings dialog. The elements in the Conduit Settings dialog are described in the following table:

    Element 

    Description 

    Action

    Select the action to perform when you do a HotSync operation. 

    Select one of the following options: 

    • Disabled: Select this option to take no action for this conduit.

    • Synchronize: Select this option to synchronize data on your PDA with data on your computer.

    • Copy from pilot: Select this option to copy data from your PDA to your computer, and overwrite the data on your computer.

    • Copy to pilot: Select this option to copy data from your computer to your PDA, and overwrite the data on your PDA.

    One Time Action

    Select an action to perform one time only. The action is performed the next time that you do a HotSync operation. Select one of the following options: 

    • None: Select this option to if you do not want to configure a one-time conduit action.

    • Synchronize: Select this option to synchronize data on your PDA with data on your computer.

    • Copy from pilot: Select this option to copy data from your PDA to your computer, and overwrite the data on your computer.

    • Copy to pilot: Select this option to copy data from your computer to your PDA, and overwrite the data on your PDA.

    Backup directory

    Enter the directory where you want to store your PDA backup data. 

    Backup conduit only.

    Only backup changed bases

    Select this option to back up only data that has changed since the last backup. The unchanged data is not deleted from your backup directory. 

    Backup conduit only.

    Remove local base if deleted on pilot

    Select this option to delete data from your computer that has been deleted from your PDA. 

    Backup conduit only.

    # of old backups to keep

    Use the spin box to specify how many previous backups to retain on your computer. 

    Backup conduit only.

    For information about the EAddress, ECalendar, and EToDo conduits, see the online Help for Email and Calendar.

  5. To configure a conduit that is enabled, select the conduit from the table, then click on the Settings button. Enter configuration details for the conduit in the Conduit Settings dialog.

  6. To disable a conduit, select the conduit from the table on the Pilot Settings dialog, then click on the Disable button.

  7. Click OK to close the Conduit Settings dialog.

To Back Up PDA Data

You might want to back up the data on your PDA to your computer, to avoid data loss if you have a problem with your PDA. To back up PDA data to your computer, perform the following steps:

  1. Click Launch, then choose Preferences -> Desktop Preferences -> PDA Devices to start the PDA Devices preference tool.

  2. Ensure that the PDA daemon is active and functions properly. To do this, add the PDA Monitor panel application to a panel. If the PDA Monitor icon appears in black and white, the PDA daemon is active.

  3. In the Conduits tabbed section on the Pilot Settings dialog, use the Pilot Name drop-down list to select the PDA whose data you want to backup.

  4. Select the Backup conduit from the table, then click on the Enable button.

  5. Enter configuration details for the Backup conduit in the Conduit Settings dialog. For more information about the elements in the Conduit Settings dialog, seeTo Specify How to Transfer PDA Data.

  6. Press the HotSync button on your PDA.

For information about how to restore backup data, see the online Help for PDA Monitor.