Solaris SAN Configuration and Multipathing Guide

Configuring Device Nodes Without Multipathing Enabled

This section describes fabric device configuration tasks on a host that does not have multipathing enabled.

The procedures in this section show how to detect fabric devices that are visible on a host and to configure and make them available to a host using the Solaris 10 OS. The procedures in this section use specific devices as examples to illustrate how to use the cfgadm(1M) command to detect and configure fabric devices.

The device information that you supply and that is displayed by the cfgadm(1M) command depends on your system configuration.

ProcedureTo Configure an Individual Device Without Multipathing

This sample procedure describes how to configure a fabric device that is attached to the fabric-connected host port c0.

  1. Log in as root (su - root).

  2. Identify the device to be configured.


    # cfgadm -al
    Ap_Id                 Type     Receptacle   Occupant     Condition
    c0                  fc-fabric  connected    unconfigured unknown
    c0::50020f2300006077 disk      connected    unconfigured unknown
    c0::50020f23000063a9 disk      connected    unconfigured unknown
    c0::50020f2300005f24 disk      connected    unconfigured unknown
    c0::50020f2300006107 disk      connected    unconfigured unknown
    c1                  fc-private connected    configured   unknown
    c1::220203708b69c32b disk      connected    configured   unknown
    c1::220203708ba7d832 disk      connected    configured   unknown
    c1::220203708b8d45f2 disk      connected    configured   unknown
    c1::220203708b9b20b2 disk      connected    configured   unknown
  3. Configure the fabric device.


    # cfgadm -c configure c0::50020f2300006077
    
  4. Verify that the selected fabric device is configured.


    # cfgadm -al
    Ap_Id                 Type      Receptacle  Occupant     Condition
    c0                   fc-fabric  connected   configured   unknown
    c0::50020f2300006077 disk       connected   configured   unknown
    c0::50020f23000063a9 disk       connected   unconfigured unknown
    c0::50020f2300005f24 disk       connected   unconfigured unknown
    c0::50020f2300006107 disk       connected   unconfigured unknown
    c1                   fc-private connected   configured   unknown
    c1::220203708b69c32b disk       connected   configured   unknown
    c1::220203708ba7d832 disk       connected   configured   unknown
    c1::220203708b8d45f2 disk       connected   configured   unknown
    c1::220203708b9b20b2 disk       connected   configured   unknown

    Notice that the Occupant column for both c0 and c0::50020f2300006077 displays as configured, indicating that the c0 port has a configured occupant and that the c0::50020f2300006077 device is configured.

  5. Use the show_SCSI_LUN option to display FCP SCSI LUN information for multi-LUN SCSI devices.

    The following code example shows that the physical devices connected through Ap_Id c0:50020f2300006077 have four LUNs configured.


    # cfgadm -al -o show_SCSI_LUN c0
    Ap_Id                 Type       Receptacle   Occupant     Condition
    c0                  fc-fabric    connected    configured   unknown
    c0::50020f2300006077,0 disk      connected    configured   unknown
    c0::50020f2300006077,1 disk      connected    configured   unknown
    c0::50020f2300006077,2 disk      connected    configured   unknown
    c0::50020f2300006077,3 disk      connected    configured   unknown

    The device is now available on the host using the Solaris 10 OS. The paths represent each SCSI LUN in the physical device represented by c0::50020f2300006077.

ProcedureTo Configure Multiple Devices Without Multipathing

Make sure you first identify the devices visible to the host with the procedure Ensuring That LUN Level Information Is Visible. This procedure describes how to configure all unconfigured fabric devices that are attached to a fabric-connected host port. The port used as an example is c0.

  1. Log in as root (su - root).

  2. Identify the devices to be configured.


    # cfgadm -al
    Ap_Id                Type        Receptacle   Occupant     Condition
    c0                   fc-fabric   connected    unconfigured unknown
    c0::50020f2300006077 disk        connected    unconfigured unknown
    c0::50020f23000063a9 disk        connected    unconfigured unknown
    c0::50020f2300005f24 disk        connected    unconfigured unknown
    c0::50020f2300006107 disk        connected    unconfigured unknown
    c1                   fc-private  connected    configured   unknown
    c1::220203708b69c32b disk        connected    configured   unknown
    c1::220203708ba7d832 disk        connected    configured   unknown
    c1::220203708b8d45f2 disk        connected    configured   unknown
    c1::220203708b9b20b2 disk        connected    configured   unknown
  3. Configure all of the unconfigured devices on the selected port.


    # cfgadm -c configure c0
    

    Note –

    This operation repeats the configure operation of an individual device for all the devices on c0. This can be time consuming if the number of devices on c0 is large.


  4. Verify that all devices on c0 are configured.


    # cfgadm -al
    Ap_Id                 Type       Receptacle  Occupant    Condition
    c0                   fc-fabric   connected   configured  unknown
    c0::50020f2300006077 disk        connected   configured  unknown
    c0::50020f23000063a9 disk        connected   configured  unknown
    c0::50020f2300005f24 disk        connected   configured  unknown
    c0::50020f2300006107 disk        connected   configured  unknown
    c1                   fc-private  connected   configured  unknown
    c1::220203708b69c32b disk        connected   configured  unknown
    c1::220203708ba7d832 disk        connected   configured  unknown
    c1::220203708b8d45f2 disk        connected   configured  unknown
    c1::220203708b9b20b2 disk        connected   configured  unknown
  5. Use the show_SCSI_LUN command to display FCP SCSI LUN information for multi-LUN SCSI devices.

    The following code example shows that the physical devices represented by c0::50020f2300006077 and c0::50020f2300006107 each have four LUNs configured. The physical devices represented by c0::50020f23000063a9 and c0::50020f2300005f24 each have two LUNs configured.


    # cfgadm -al -o show_SCSI_LUN c0
    Ap_Id                 Type     Receptacle   Occupant     Condition
    c0                  fc-fabric  connected    configured   unknown
    c0::50020f2300006077,0 disk    connected    configured   unknown
    c0::50020f2300006077,1 disk    connected    configured   unknown
    c0::50020f2300006077,2 disk    connected    configured   unknown
    c0::50020f2300006077,3 disk    connected    configured   unknown
    c0::50020f23000063a9,0 disk    connected    configured   unknown
    c0::50020f23000063a9,1 disk    connected    configured   unknown
    c0::50020f2300005f24,0 disk    connected    configured   unknown
    c0::50020f2300005f24,1 disk    connected    configured   unknown
    c0::50020f2300006107,0 disk    connected    configured   unknown
    c0::50020f2300006107,1 disk    connected    configured   unknown
    c0::50020f2300006107,2 disk    connected    configured   unknown
    c0::50020f2300006107,3 disk    connected    configured   unknown