Release Notes for Sun Storage 6580 and 6780 Arrays

This document contains important release information about the Sun Storage 6580 and 6780 Arrays running Sun StorageTek Common Array Manager (CAM), Release 6.5. Read this document so that you are aware of issues or requirements that can affect the installation and operation of the arrays.

The release notes consist of the following sections:

For Information About CAM

See the Sun StorageTek Common Array Manager software documentation for the CAM 6.5.0 release at:

http://docs.sun.com/app/docs/prod/6780.array~cam6.5?l=en#hic

For Related Patch Information

Look for the latest patches pertaining to your environment at:

http://sunsolve.sun.com/show.do?target=patchpage

1. In the Search box in the masthead, enter 6580 or 6780.

2. Filter Results By: Downloads > Patches.

A listing of available patches related to the array are listed.


What’s In This Firmware Release

Array controller firmware version 07.60.xx.xx includes bug fixes and data host support for SUSE Linux Enterprise 11 platforms.

The firmware is provided with Sun StorageTek Common Array Manager (CAM) v. 6.5.0 or available for download at:

http://www.sun.com/storage/management_software/resource_management/cam

Click the “Get It” tab to download the latest CAM software.

For more inforamtion about bug fixes, see the Sun StorageTek Common Array Manager Release Notes, 6.5.0.

The Sun Storage 6580 and 6780 Arrays are compared in TABLE 1.


TABLE 1 Comparison of Sun Storage 6580 and 6780 Array Configurations

6580

6780

Total cache size per array

8 or 16 Gbytes

8 or 16 Gbytes

Number of host ports

8 4-Gbit/second or 8 G-bit/second

8 or 16 4-Gbit/second or 8-Gbit/second

Host interface cards

2

2 or 4

Maximum number of drives supported

256

448

Disk reads

IOPS[1] 115K
Throughput 3000 MB/second

IOPS* 175K
Throughput 6400 MB/second

Maximum array configuration

1x16

1x28

Maximum raw capacity

256 Tbytes

448 Tbytes



System Requirements

The software and hardware products that have been tested and qualified to work with the Sun Storage 6580 and 6780 Arrays are described in the following sections.

Minimum Firmware Requirements

The firmware version for Sun Storage 6580 and 6780 Arrays features described in this release note is version 07.60.xx.xx. This firmware version (or higher) is installed on the array controllers prior to shipment and is also delivered with Sun StorageTek Common Array Manager (CAM) v, 6.5.0.

Disk Drives and Tray Capacity

TABLE 2 lists the size, speed, and tray capacity for the supported FC and SATA disk drives for Sun Storage 6580 and 6780 Arrays.


TABLE 2 Supported Disk Drives

Drive

Description

FC 146G15K

146-Gbyte 15,000-RPM FC drives

(4 Gbits/sec); 2336 Gbytes per tray

FC 300G15K

300-Gbyte 15,000-RPM FC drives
(4 Gbits/sec); 4800 Gbytes per tray

FC 400G10K

400-Gbyte 10,000-RPM FC drives
(4 Gbits/sec): 6400 Gbytes per tray

FC 450G15K

450-Gbyte 15,000-RPM FC drives
(4 Gbits/sec); 7200 Gbytes per tray

SATA 2, 500G7.2K

500-Gbyte 7,200-RPM SATA drives

(3 Gbits/sec); 8000 Gbytes per tray

SATA 2, 750G7.2K

750-Gbyte 7,200-RPM SATA drives
(3 Gbits/sec); 12000 Gbytes per tray

SATA 2, 1T7.2K

1-Tbyte 7,200-RPM SATA drives
(3 Gbits/sec); 16000 Gbytes per tray


Additional legacy drives might also be supported with this product.

Data Host Requirements

This section describes supported data host software, HBAs, and switches.

Multipathing Software

This section provides a summary of the data host requirements for the Sun Storage 6580 and 6780 Arrays. It lists the current multipathing software and supported host bus adapters (HBAs) by operating system.

You must install multipathing software on each data host that communicates with Sun Storage 6580 and 6780 Arrays.

For Solaristrademark Operating System (OS) 9 data hosts, the multipathing software is part of the Sun StorageTek SAN Foundation software. For data hosts running the Solaris OS, follow the instructions in the Hardware Installation Guide for Sun Storage 6580 and 6780 Arrays to download and install the software from the Sun Download Center.

Solaris OS 10 includes the multipathing software.

TABLE 3 lists supported multipathing software by operating system.


TABLE 3 Multipathing Software

OS

Multipathing Software

Minimum Version

Latest Version

Host Type Setting

Notes

Solaris 9 SPARC

STMS/MPxIO

SFK 4.4.13

SFK 4.4.14

Solaris with MPxIO

 

Solaris 10

STMS/MPxIO

Update 6 or

Update 5 with patch 140919-04 (SPARC), 140920-04 (x64/x86)

Kernel Jumbo Patch (KJP)

Solaris with MPxIO

 

Solaris 9,10 with DMP

Symantec Veritas Dynamic Multi-Pathing (DMP)

5.0MP3

5.0MP3

Solaris with DMP

 

Windows 2003 Non-clustered

MPIO

01.03.0302.0215

01.03.0302.0215

(MPIO)

Windows 2003

Non-clustered

 

Windows MSCS Cluster

MPIO

01.03.0302.0215

01.03.0302.0215 (MPIO)

Windows Server 2003 Clustered

 

Windows 2003

Non-clustered with DMP

DMP

5.0MP3

5.1

Windows Server 2003 Non-clustered (with Veritas DMP)

Pending vendor qualification, see Symantec’s HCL

Windows 2003 Clustered with DMP

DMP

5.0MP3

5.1

Windows Server 2003 clustered (with Veritas DMP)

Pending vendor qualification, see Symantec’s HCL

Windows 2008

MPIO

01.03.0302.0215

01.03.0302.0215

Windows Server 2003

 

AIX 6.1

Cambex DPF

6.1.0.63

6.1.0.63

AIX

 

AIX 5.3, 6.1 with DMP

DMP

5.0

5.0MP3

AIX with DMP

Pending vendor qualification, see Symantec’s HCL

Red Hat 4
SuSE 9/SuSE 10

RDAC/MPP

09.09.B02.0214

09.09.B02.0214

Linux

 

Red Hat 5
SuSE 10 SP1 (and above)

RDAC/MPP

09.03.0C00.0042

09.09.0C02.0214

Linux

 

Red Hat 5 (and above)

RDAC

09.03.0C00.0042

09.09.0C02.0214

Linux

 

Red Hat
SuSE with DMP

DMP

5.0MP3

5.0MP3

Linux with DMP

Pending vendor qualification, see Symantec’s HCL

HPUX

Veritas DMP

5.0MP3

5.0MP3

HP-UX

Pending vendor qualification, see Symantec’s HCL




Note - Download the MPIO and RDAC multipathing drivers from the Sun Download Center http://www.sun.com/download/index.jsp?tab=2.




Note - The multipathing driver for the IBM AIX platform is Veritas DMP, bundled in Veritas Storage Foundation 5.0 for Sun Storage 6580 and 6780 Arrays. Download the Array Support Library (ASL) from http://support.veritas.com/.


Supported Host Bus Adaptors (HBAs)

TABLE 4, TABLE 5, and TABLE 6 lists supported HBAs and other data host platform elements by operating system.

HBAs must be ordered separately from Sun or its respective manufacturers. Sun HBAs can be ordered from:

http://www.sun.com/storagetek/storage_networking/hba/

You can download HBA drivers and other host software from the Sun Download Center at:

http://www.sun.com/software/download/

Download operating system updates from the web site of the operating system company.

You must install the multipathing software before you install any OS patches.


TABLE 4 Supported HBAs for Solaris Data Host Platforms

Operating System

Minimum OS Patches

Sun 2-Gbit HBAs

Sun 4-Gbit HBAs

Sun 8-Gb HBAs

Solaris 9

113277-44 or higher

SG-XPCI1FC-QL2 (6767A)

SG-XPCI2FC-QF2-Z (6768A)

SG-XPCI1FC-EM2

SG-XPCI2FC-EM2

SG-XPCI1FC-QF4

SG-XPCI2FC-QF4

SG-XPCI2FC-EM4-Z

SG-XPCI1FC-EM4-Z

N/A

Solaris 10 SPARC

Update 6 or Update 5 with patch 140919-04

SG-XPCI1FC-QL2 (6767A)

SG-XPCI2FC-QF2-Z (6768A)

SG-XPCI1FC-EM2

SG-XPCI2FC-EM2

SG-XPCIE1FC-QF4

SG-XPCIE2FC-QF4

SG-XPCIE1FC-EM4

SG-XPCIE2FC-EM4

SG-XPCI1FC-QF4

SG-XPCI2FC-QF4

SG-XPCI1FC-EM4

SG-XPCI2FC-EM4

SG-XPCIE2FCGBE-Q-Z SG-XPCIE2FCGBE-E-Z

SG-XPCIE1FC-QF8-Z

SG-XPCIE2FC-QF8-Z

SG-XPCIE1FC-EM8-Z

SG-XPCIE2FC-EM8-Z

Solaris 10 x64/x86

Update 6 or Update 5 with patch 140920-04

SG-XPCI1FC-QL2 (6767A)

SG-XPCI2FC-QF2-Z (6768A)

SG-XPCI1FC-EM2

SG-XPCI2FC-EM2

SG-XPCIE1FC-QF4

SG-XPCIE2FC-QF4

SG-XPCIE1FC-EM4

SG-XPCIE2FC-EM4

SG-XPCI1FC-QF4

SG-XPCI2FC-QF4

SG-XPCI1FC-EM4

SG-XPCI2FC-EM4

SG-XPCIE2FCGBE-Q-Z

SG-XPCIE2FCGBE-E-Z

SG-XPCIE1FC-QF8-Z

SG-XPCIE2FC-QF8-Z

SG-XPCIE1FC-EM8-Z

SG-XPCIE2FC-EM8-Z


 


TABLE 5 Supported HBAs for Microsoft Windows Data Host Platforms

Host OS / Servers

HBAs

Sun 2-Gb HBAs

Sun 4-Gb HBAs

Sun 8-Gb HBAs

Microsoft Windows 2008 Server 32-bit / x86 (IA32)

QLogic QLE 256x

QLogic QLE 246x

QLogic QLA 246x

QLogic QLA 234x

QLogic QLA 2310F

Emulex LPe12000/LPe12002/LPe1250

Emulex Lpe11000/LPe11002/LPe1150

Emulex LP11000/LP11002/LP1150

Emulex LP9802/9802DC/982

Emulex LP952/LP9002/LP9002DC

Emulex 10000/10000DC/LP1050

SG-XPCI1FC-EM2

SG-XPCI2FC-EM2

SG-XPCI1FC-QL2

SG-XPCI2FC-QF2-Z

SG-XPCIE1FC-QF4

SG-XPCIE2FC-QF4

SG-XPCIE1FC-EM4

SG-XPCIE2FC-EM4

SG-XPCI1FC-QF4

SG-XPCI2FC-QF4

SG-XPCI1FC-EM4

SG-XPCI2FC-EM4

SG-XPCIE2FCGBE-Q-Z

SG-XPCIE2FCGBE-E-Z

SG-XPCIE1FC-QF8-Z

SG-XPCIE2FC-QF8-Z

SG-XPCIE1FC-EM8-Z

SG-XPCIE2FC-EM8-Z

64-bit / x64 (AMD)

EM64T

IA64

Microsoft Windows 2003

32-bit with SP1 R2 / x86 (IA32)

QLogic QLE 256x

QLogic QLE 246x

QLogic QLA 246x

QLogic QLA 234x

QLogic QLA 2310F

Emulex LPe12000/LPe12002/LPe1250

Emulex Lpe11000/LPe11002/LPe1150

Emulex LP11000/LP11002/LP1150

Emulex LP9802/9802DC/982

Emulex LP952/LP9002/LP9002DC

Emulex 10000/10000DC/LP1050

SG-XPCI1FC-EM2

SG-XPCI2FC-EM2

SG-XPCI1FC-QL2

SG-XPCI2FC-QF2-Z

SG-XPCIE1FC-QF4

SG-XPCIE2FC-QF4

SG-XPCIE1FC-EM4

SG-XPCIE2FC-EM4

SG-XPCI1FC-QF4

SG-XPCI2FC-QF4

SG-XPCI1FC-EM4

SG-XPCI2FC-EM4

SG-XPCIE2FCGBE-Q-Z

SG-XPCIE2FCGBE-E-Z

SG-XPCIE1FC-QF8-Z

SG-XPCIE2FC-QF8-Z

SG-XPCIE1FC-EM8-Z

SG-XPCIE2FC-EM8-Z

Microsoft Windows 2003

64-bit with SP1 R2 / x64 (AMD)

EM64T

IA64

QLogic QLE 256x

QLogic QLE 246x

QLogic QLA 246x

QLogic QLA 234x

QLogic QLA 2310F

Emulex LPe12000/LPe12002/

LPe1250

Emulex Lpe11000/LPe11002/LPe1150

Emulex LP11000/LP11002/LP1150

Emulex LP9802/9802DC/982

Emulex LP952/LP9002/LP9002DC

Emulex 10000/10000DC/LP1050

SG-XPCI1FC-EM2

SG-XPCI2FC-EM2

SG-XPCI1FC-QL2

SG-XPCI2FC-QF2-Z

SG-XPCIE1FC-QF4

SG-XPCIE2FC-QF4

SG-XPCIE1FC-EM4

SG-XPCIE2FC-EM4

SG-XPCI1FC-QF4

SG-XPCI2FC-QF4

SG-XPCI1FC-EM4

SG-XPCI2FC-EM4

SG-XPCIE2FCGBE-Q-Z

SG-XPCIE2FCGBE-E-Z

SG-XPCIE1FC-QF8-Z

SG-XPCIE2FC-QF8-Z

SG-XPCIE1FC-EM8-Z

SG-XPCIE2FC-EM8-Z


 

TABLE 6 Supported HBAs for Linux Data Host Platforms

Host OS / Sun Servers

HBAs

Sun 2-Gb HBAs

Sun 4-Gb HBAs

Sun 8-Gb HBAs

Linux SuSE 10.2 SuSE 11

QLogic QLE 256x

QLogic QLE246x

QLogic QLA 246x

QLogic QLA 234x

QLogic QLA 2310F

Emulex LP982/LP9802/9802DC

Emulex LP9002/LP9002DC/LP952

Emulex LP10000/10000DC/LP1050

Emulex LP11000/LP11002/LP1150

Emulex Lpe11000/LPe11002/LPe1150

Lpe12000/LPe12002/
Lpe1250

SG-XPCI1FC-EM2

SG-XPCI2FC-EM2

SG-XPCI1FC-QL2

SG-XPCI2FC-QF2-Z

SG-XPCIE1FC-QF4

SG-XPCIE2FC-QF4

SG-XPCIE1FC-EM4

SG-XPCIE2FC-EM4

SG-XPCI1FC-QF4

SG-XPCI2FC-QF4

SG-XPCI1FC-EM4

SG-XPCI2FC-EM4

SG-XPCIE2FCGBE-Q-Z

SG-XPCIE2FCGBE-E-Z

SG-XPCIE1FC-QF8-Z

SG-XPCIE2FC-QF8-Z

SG-XPCIE1FC-EM8-Z

SG-XPCIE2FC-EM8-Z

Linux SuSE 9.0 - IA 32, 2.6 kernel / x64

EM64T

x86 (IA32)

IA64

QLogic QLE 256x

QLogic QLE246x

QLogic QLA 246x

QLogic QLA 234x

QLogic QLA 2310F

Emulex LP982/LP9802/9802DC

Emulex LP9002/LP9002DC/LP952

Emulex LP10000/10000DC/LP1050

Emulex LP11000/LP11002/LP1150

Emulex Lpe11000/LPe11002/LPe1150

SG-XPCI1FC-EM2

SG-XPCI2FC-EM2

SG-XPCI1FC-QL2

SG-XPCI2FC-QF2-Z

SG-XPCIE1FC-QF4

SG-XPCIE2FC-QF4

SG-XPCIE1FC-EM4

SG-XPCIE2FC-EM4

SG-XPCI1FC-QF4

SG-XPCI2FC-QF4

SG-XPCI1FC-EM4

SG-XPCI2FC-EM4

SG-XPCIE2FCGBE-Q-Z

SG-XPCIE2FCGBE-E-Z

SG-XPCIE1FC-QF8-Z

SG-XPCIE2FC-QF8-Z

SG-XPCIE1FC-EM8-Z

SG-XPCIE2FC-EM8-Z

RHEL 5u2

RHEL 5u3

QLogic QLE 256x

QLogic QLE 246x

QLogic QLA 246x

QLogic QLA 234x

QLogic QLA 2310F

Emulex LP982/LP9802/9802DC

Emulex LP9002/LP9002DC/LP952

Emulex LP10000/10000DC/LP1050

Emulex Lpe11000/LPe11002/LPe1150

Emulex Lpe12000/LPe12002/
LPe1250

SG-XPCI1FC-EM2

SG-XPCI2FC-EM2

SG-XPCI1FC-QL2

SG-XPCI2FC-QF2-Z

SG-XPCIE1FC-QF4

SG-XPCIE2FC-QF4

SG-XPCIE1FC-EM4

SG-XPCIE2FC-EM4

SG-XPCI1FC-QF4

SG-XPCI2FC-QF4

SG-XPCI1FC-EM4-Z

SG-XPCI2FC-EM4-Z

SG-XPCIE2FCGBE-Q-Z

SG-XPCIE2FCGBE-E-Z

SG-XPCIE1FC-QF8-Z

SG-XPCIE2FC-QF8-Z

SG-XPCIE1FC-EM8-Z

SG-XPCIE2FC-EM8-Z

RHEL 4u7

RHEL 4.8

QLogic QLE 256x

QLogic QLE 246x

QLogic QLA 246x

QLogic QLA 234x

QLogic QLA 2310F

Emulex LP982/LP9802/9802DC

Emulex LP9002/LP9002DC/LP952

Emulex LP10000/10000DC/LP1050

Emulex Lpe11000/LPe11002/LPe1150

Emulex Lpe12000/LPe12002/
Lpe1250

SG-XPCI1FC-EM2

SG-XPCI2FC-EM2

SG-XPCI1FC-QL2

SG-XPCI2FC-QF2-Z

SG-XPCIE1FC-QF4

SG-XPCIE2FC-QF4

SG-XPCIE1FC-EM4

SG-XPCIE2FC-EM4

SG-XPCI1FC-QF4

SG-XPCI2FC-QF4

SG-XPCI1FC-EM4-Z

SG-XPCI2FC-EM4-Z

SG-XPCIE2FCGBE-Q-Z

SG-XPCIE2FCGBE-E-Z

SG-XPCIE1FC-QF8-Z

SG-XPCIE2FC-QF8-Z

SG-XPCIE1FC-EM8-Z

SG-XPCIE2FC-EM8-Z


 


TABLE 7 Other Supported Data Host Platforms

Host OS

Host Servers

HBAs

Novell NetWare 6.5 (SP7)

x86 (IA32)

QLogic QLA 2342

QLogic QLA 2340

QLogic QLA 2310F

QLogic QLA 246x

Novell NetWare 6.5 (SP3)

x86 (IA32)

QLogic QLA 2342

QLogic QLA 2340

QLogic QLA 2310F

QLogic QLA 246x

HP-UX 11.31

HP RISC

IA64

HP A6795A

HP A6826A

HP A6684A

HP A6685A

HP AB378A

HP AB379A

HP AD300A

HP AD355A

AH400A (IA64)

AH401A (IA64)

HP-UX B.11.23

HP RISC

IA64

HP A6795A

HP A6826A

HP A9784A

HP AB378A

HP AB379A

HP AD300A

HP AD355A

IBM AIX 5.2, 5.3, 6.1

Power

IBM 5716

IBM 5758

IBM 5759

IBM 6228

IBM 6239


Supported Enterprise Software

The enterprise software applications listed in TABLE 8 are compatible with the Solaris OS on the data host.


TABLE 8 Supported Enterprise Software

Software

Version

Legato NetWorker

7.3

Sun Cluster

3.0, 3.1

Sun StorageTek QFS software

4.0 minimum

Sun StorageTek SAM-FS software

4.0 minimum

Sun StorageTek Availability Suite

3.2 minimum

Sun StorageTek Enterprise Backup Software

7.3

Solaris Volume Manager

Embedded in the Solaris 9 and 10 OSs

VERITAS Storage Foundation (VxVM/VxFS)

5.0

VERITAS Cluster Server (VCS)

5.0

VERITAS NetBackup

6.0 or higher


Supported FC and Multilayer Switches

The following FC fabric and multilayer switches are compatible for connecting data hosts and Sun Storage 6580 and 6780 Arrays:


Known Issues

The following sections provide information about known issues and bugs filed against this product release:

If a recommended workaround is available for a bug, it follows the bug description.

Installation and Hardware Related Issues

This section describes known issues and bugs related to installing and initially configuring Sun Storage 6580 and 6780 Arrays.

Setting the Tray Link Rate

When setting the tray link rate for an expansion tray, all expansion trays connected to the same drive channel must be set to operate at the same data transfer rate (speed).

For details about how to set the tray link rate, see “Setting the Tray Link Rate” in the Hardware Installation Guide for Sun Storage 6580 and 6780 Arrays.

Upgrading the Sun StorageTek 6540 Array

Bug CR 6783749 - When upgrading a Sun StorageTek 6540 array to a Sun Storage 6580 or 6780 Array, you cannot change the tray ID 85 to tray ID 99 using CAM.

Workaround - You can use controller tray ID 85 for array configurations up to a maximum of 256 drives.

Hardware Issues

This section describes general issues related to Sun Storage 6580 and 6780 Arrays hardware and firmware.

Replacing CRUs/FRUs in Less Than 15 Minutes


caution icon Caution - Without adequate ventilation and air circulation, the controller tray will overheat resulting in potential damage to all customer-replaceable units (CRUs) or field-replaceable units (FRUs). Do not allow any CRU/FRU slot to remain empty for an extended time. Replace the failed CRU/FRU within 15 minutes.


System Cabinet Doors Must Be Closed


caution icon Caution - The front and back doors of the system cabinet must be closed for compliance to domestic and international EMI regulations as well as proper equipment cooling. Do not block or cover the openings of the system cabinet. Cabinet airflow is from front to back. Allow at least 30 inches (76.2 cm) in front of the cabinet, and at least 24 (60.96 cm) inches behind the cabinet, for service clearance, proper ventilation, and heat dissipation.


Intermittent Power Supply Failure Notification

Bug 6760395 - CAM logEvent messages intermittently reports power supply failures and 12 seconds later changes to optimal. This is caused by devices not responding to polling.

Workaround - No workaround required. You can ignore the failure messages.

The cfgadm -c unconfigure Command Unconfigures UTM LUNs Only and Not Other Data LUNs (Solaris 10)

Bug 6362850 - The cfgadm -c unconfigure command unconfigures Universal Transport Mechanism (UTM) LUNs only and not other data LUNs. When this happens, you will not be able to unconfigure LUNs.

Workaround - Obtain Solaris 10 patch 118833-20 (SPARC) or patch 118855-16 (x86) to fix this issue.

Tray ID Diagnostic Codes

See Appendix C, Troubleshooting and Operational Procedures, in the Hardware Installation Guide for Sun Storage 6580 and 6780 Arrays for a description of the controller tray and expansion tray diagnostic codes.


Product Documentation

Related product documentation is available at the Sun documentation web site:

http://docs.sun.com/app/docs/prod/6780.array#hic

For translated versions of the documentation, go to the http://docs.sun.com web site, select your language, and search for the product documentation.


Application

Title

Part Number

Site planning information

Site Planning Guide for Sun Storage 6580 and 6780 Arrays

820-5775

Regulatory and safety information

Sun Storage Regulatory and Safety Compliance Manual

820-5506

Installation overview for rack-mounted arrays

Getting Started Guide for Sun Storage 6580 and 6780 Rack Mounted Arrays

820-5772

 

Getting Started Guide for Sun Storage 6580 and 6780 Rack Ready Arrays

820-6875

Rack installation instructions

Sun Rack II User’s Guide

820-4759

Rail kit installation instructions

Sun Modular Storage Rail Kit Installation Guide

820-5774

PDU installation instructions

Power Distribution Unit Installation Guide for Sun Storage 6580 and 6780 Arrays and Sun StorageTek 2500 and 6000 Array Series

820-6200

Array installation instructions

Hardware Installation Guide for Sun Storage 6580 and 6780 Arrays

820-5773

Upgrade a Sun StorageTek 6540 array to a Sun Storage 6580 or 6780 array

Sun Storage 6000 Series Hardware Upgrade Guide for Sun StorageTek 6540 Array to Sun Storage 6580 Array and Sun Storage 6780 Array Upgrades

820-7003

Release-specific information for the Sun StorageTek Common Array Manager

Sun StorageTek Common Array Manager Release Notes, v. 6.5.0

821-0126

Software installation and initial configuration instructions

Sun StorageTek Common Array Manager Software Installation Guide, v6.5

820-7921

Reference information for the Common Array Manager CLI

Sun StorageTek Common Array Manager CLI Guide

821-0132

Release-specific information for the Sun StorageTek Common Array Manager

Sun StorageTek Common Array Manager Release Notes, v6.5.0

821-0126

Multipath failover driver installation and configuration

Sun StorageTek MPIO Device Specific Module Installation Guide For Microsoft Windows OS

820-4737

Sun StorageTek RDAC Multipath Failover Driver Installation Guide For Linux OS

820-4738



Service Contact Information

If you need help installing or using this product, go to:

http://www.sun.com/service/contacting


Third-Party Web Sites

Sun is not responsible for the availability of third-party web sites mentioned in this document. Sun does not endorse and is not responsible or liable for any content, advertising, products, or other materials that are available on or through such sites or resources. Sun will not be responsible or liable for any actual or alleged damage or loss caused by or in connection with the use of or reliance on any such content, goods, or services that are available on or through such sites or resources.


1 (TableFootnote) Input/output operations per second