Confirming Server Specifications
Optional Component Installation
Determine Correct Rackmount Hardware
Mark the Rackmounting Location
Install the Rackmount Hardware
Installing and Using the Shipping Bracket Assembly (Optional)
Front Panel Connectors and Ports
Rear Panel Connectors and Ports
Installing and Using the CMA (Optional)
Connect the Ethernet Network Cables
Powering On the Server for the First Time
Oracle ILOM System Console Overview
Connect a Terminal or Emulator to the SER MGT Port
Power On the Server for the First Time
Oracle Solaris OS Configuration Parameters
Assigning a Static IP Address to the Service Processor
Booting the Oracle Solaris Operating System
Understanding System Administration Resources
Platform-Specific Oracle ILOM Features
Oracle VM Server for SPARC Overview
Hardware Management Pack Overview
Source for Downloading Hardware Management Pack Software
Hardware Management Pack Documentation
Display the Oracle ILOM -> Prompt
Reset the Server From the Oracle Solaris OS
Reset the Server From Oracle ILOM
Reset the SP to Default Values
Important Hardware RAID Guidelines
Disk Zones for SPARC T3-1 Servers With Sixteen-Disk Backplanes
Displaying Disk Zone Information
Enabling and Disabling Disk Zoning In the Field
Prepare to Use the FCode Utility
Hot Spare Drives in RAID Volumes (LSI)
Determining If a Drive Has Failed
RAID Drive Replacement Strategies
Changing Server Identification Information
Change Customer FRUdata Information
Change System Identifier Information
Restore Host Power State at Restart
Specify Host Power State at Restart
Disable or Re-Enable Power-On Delay
Specify Parallel Boot of the SP and Host
Configure Host Behavior With the Keyswitch State
Disable or Re-Enable Network Access to the SP
Display the DHCP Server IP Address
Using an In-band Connection to the SP
Configure the Host Boot Mode of Oracle VM Server for SPARC
Change the Host Boot Mode Behavior at Reset
Manage the Host Boot Mode Script
Display Host Boot Mode Expiration Date
Override OpenBoot PROM Settings to Reset the Server
Configuring Server Behavior at Restart
Specify Behavior When the Host Resets
Specify Behavior When the Host Stops Running
Specify Behavior at Boot Timeout
Specify Behavior if Restart Fails
Specify Maximum Restart Attempts
Enabling Automatic System Recovery
Identifying WWN-Designated SAS2 Devices
probe-scsi-all Output Example (SPARC T3-1, Eight-Disk Backplane)
probe-scsi-all Output Example (SPARC T3-1, Sixteen-Disk Backplane)
probe-scsi-all Output Example (SPARC T3-4)
Identify a Disk Slot Using probe-scsi-all (OBP)
Identify a Disk Slot Using prtconf (Oracle Solaris, Onboard Controllers)
Identify a Disk Slot Using prtconf (Oracle Solaris, Single Initiator)
WWN Syntax in an OS Installation on a Specific Device
WWN Syntax in an OS Installation on a RAID Volume
Access the Service Processor (ILOM)
Display FRU Information (show Command)
Check for Faults (show faulty Command)
Check for Faults (fmadm faulty Command)
Fault Managment Command Examples
Interpreting Log Files and System Messages
Using Oracle Solaris Predictive Self-Healing
ILOM Properties That Affect POST Behavior
Find the Chassis Serial Number
Understanding Component Replacement Categories
Removing Power From the System
Processor Module Configuration Reference
Replacing a Faulty Processor Module
Install a New Processor Module
Verify Processor Module Functionality
Memory Fault Handling Overview
Understanding DIMM Configurations
Locate a Faulty DIMM Using the DIMM Fault Remind Button
Locate a Faulty DIMM Using the show faulty Command
Increase System Memory With Additional DIMMs
Hard Drive Hot-Pluggable Capabilities
Hard Drive Configuration Reference
Verify Hard Drive Functionality
Power Supply and AC Power Connector Configuration Reference
Power Supply and AC Power Connector LEDs
Verify Power Supply Functionality
Servicing RAID Expansion Modules
Remove the RAID Expansion Module
Install the RAID Expansion Module
Servicing the Service Processor
Locate a Faulty Service Processor
Verify Service Processor Functionality
Fan Module Configuration Reference
Verify Fan Module Functionality
Express Module Configuration Reference
Locate a Faulty Express Module
Verify Express Module Functionality
Locate a Faulty Rear I/O Module
Verify Rear I/O Module Functionality
Servicing the System Configuration PROM
System Configuration PROM Overview
Remove the System Configuration PROM
Install the System Configuration PROM
Servicing the Front I/O Assembly
Install the Front I/O Assembly
Servicing the Storage Backplane
Servicing the Main Module Motherboard
Main Module Motherboard Overview
Locate a Faulty Main Module Motherboard
Remove the Main Module Motherboard
Install the Main Module Motherboard
Verify Main Module Motherboard Functionality
Servicing the Rear Chassis Subassembly
Rear Chassis Subassembly Overview
Remove the Rear Chassis Subassembly
Install the Rear Chassis Subassembly
Returning the Server to Operation
Connect Power Cords to the Server
Power On the Server (start /SYS Command)
Use the clear_fault_action property of a FRU with the set command to manually clear ILOM-detected faults from the service processor.
If Oracle ILOM detects the FRU replacement, it will automatically clear the fault so that manual clearing of the fault is not necessary. For PSH diagnosed faults, if the replacement of the FRU is detected by the system or the fault is manually cleared on the host, the fault will also be cleared from the service processor. In such cases, manual fault clearing will typically not be required.
Note - For PSH-detected faults, this procedure clears the fault from the service processor but not from the host. If the fault persists in the host, clear it manually as described in Clear PSH-Detected Faults.
This example begins with an excerpt from the fmadm faulty command showing power supply 0 with a voltage failure. After the fault condition is corrected (a new power supply has been installed), the fault state is cleared manually.
Note - In this example, the characters “SPT” at the beginning of the message ID indicate that the fault was detected by Oracle ILOM.
[...]
faultmgmtsp> fmadm faulty
------------------- ------------------------------------ -------------- -------
Time UUID msgid Severity
------------------- ------------------------------------ -------------- -------
2010-08-27/19:46:26 edc898a3-c875-6b86-851a-91a4ed8ad58e SPT-8000-MJ Critical
Fault class : fault.chassis.power.fail
FRU : /SYS/PS0
(Part Number: 300-2159-05)
(Serial Number: 1908BAO-1020A90156)
Description : A Power Supply has failed and is not providing power to the
server.
[...]
-> set /SYS/PS0 clear_fault_action=true
Are you sure you want to clear /SYS/PS0 (y/n)? y
-> show
/SYS/PS0
Targets:
VINOK
PWROK
CUR_FAULT
VOLT_FAULT
FAN_FAULT
TEMP_FAULT
V_IN
I_IN
V_OUT
I_OUT
INPUT_POWER
OUTPUT_POWER
Properties:
type = Power Supply
ipmi_name = PS0
fru_name = /SYS/PS0
fru_description = Powersupply
fru_manufacturer = Delta Electronics
fru_version = 03
fru_part_number = 3002235
fru_serial_number = 003136
fault_state = OK
clear_fault_action = (none)
Commands:
cd
set
show