Getting Started

Location of Device Drivers on Tools and Drivers DVD

Which Device Drivers to Incorporate Into WIM Image(s)

Prerequisites and Task Overview

Procedures for Incorporating Drivers Into WIM Image(s)

Before you Begin

Create an ImageUnattend.xml Setup Script - Windows Server 2008 (SP2 or R2)

Add Device Driver(s) to Boot WIM - Windows Server 2008 SP2 Only

Map ImageUnattend.xml Setup Script to Windows Server 2008 (SP2 or R2) Install Image

F.  Identifying Network Interfaces in Windows

Procedures for Identifying Network Interfaces

Index

Create an ImageUnattend.xml Setup Script – Windows Server 2008 (SP2 or R2)

Follow these steps to create an ImageUnattend.xml Setup Script for a Windows Server 2008 (SP2 or R2) installation. After the setup script is generated, it will be saved to the device driver repository.


Note - The ImageUnattend.xml Setup Script (in a later procedure described in this section) will be mapped to a Windows Server 2008 (SP2 or R2) install image. After the setup script is mapped to the install image, the install image will install the specified device drivers during the Windows Server 2008 (SP2 or R2) network installation.


  1. Insert the Windows Server 2008 (SP2 or R2) DVD media into the DVD reader of the system that is hosting the Windows Deployment Services.

  2. Copy all the Windows Server 2008 (SP2 or R2) catalog files into the Catalogs folder of the device driver repository.

    For example:

    copy DVDDrive:\source\*.clg C:\Unattend\Drivers\{WSK8|W28R2}\Catalogs

  3. Launch the Windows System Manager application and create a new ImageUnattend.xml Setup Script by doing the following:

    1. Click Start-->All Programs -->Microsoft Windows AIK -->Windows System Image Manager.

    2. In the Answer File pane, right-click and select New Answer File.

    3. If a message dialog appears asking to open a new Windows image now, click No.

  4. Do the following to specify the Windows Server 2008 (SP2 or R2) Catalog file that matches the Windows Server 2008 (SP2 or R2) edition (Standard, Datacenter, or Enterprise) that you are installing:

    1. In the Windows Image pane, right-click and select Select Windows Image.

    2. In the Files Type list box, select Catalog files (*.clg), then click Browse to specify the Catalogs folder in the device driver repository.

      Ensure that you select the Catalog file that matches the Windows Server 2008 (SP2 or R2) edition you are installing

      For example, for Windows Server 2008 SP2 Datacenter, select:

      C:\Unattend\Drivers\{W2K8|W2K8R2}\Catalogs\install_Windows_Server_2008_SERVERDATACENTER.clg


    WSIM Catalog
  5. Do the following to set the component packages to pass 2 offlineServing.

    1. In the Windows Image pane, click and expand the architecture_Microsoft-Windows-PnPCustomizationNonWinPE_version.

    2. Right -click PathAndCredientials and select Add Setting to Pass 2 OfflineServing.


    WSIM - Add Setting to Pass 2 Offline Servicing
  6. Repeat Step 5 for each device driver you want installed during the Windows Server 2008 (SP2 or R2) installation.

    Refer to Device Drivers to Add to WIM Image(s) for the list of device drivers to include in the install.wim file.

  7. Do the following to specify an installation key value.

    1. In the Answer File pane, click and expand 2 offlineServicing,architecture_Microsoft-Windows- PnPCustomizationsNonWinPE_version.

    2. Click and expand PathAndCredentials and enter a sequence key value as well as the UNC device driver path in the repository.

      For example, to add the device driver for the Sun Storage SAS RAID HBA option, enter:

      Key 1

      Path \\wds-server\W2K8-Drivers\Lsi\1.19.2.64

    3. In the Credential section for each PathAndCredentials component, click and expand the component to insert the UNC domain, logon, and password (if required), which allow access to the device drivers stored in the repository.

      For example:


      Domain
      UNC_domain
      Password
      UNC_password
      Username
      UNC_username

      WSIM Add Key UNC Path
    4. Repeat Steps 7a through 7c for each device driver you want installed during the Windows Server 2008 (SP2 or R2) installation.

  8. Validate the ImageUnattend.xml file using the Windows System Image Manager application:

    • In the Windows System Image Manager application, click the Tools menu and select Validate Answer File.

      A message appears in the Message pane indicating that No Warnings or Errors are found.

  9. Save the .xml Setup Script as ImageUnattend.xmlusing the Windows System Manager application:

    1. In the Windows System Image Manager application, click the File menu and select Save Answer File as.

    2. Save the .xml Setup Script in the device driver repository as:

      c:\Unattend\Drivers\W2K8\Catalogs\ImageUnattend.xml

    3. Exit the Windows System Image Manager application.

  10. The creation of the ImageUnattend.xml Setup Script is complete. Proceed to one of the following: