Documentation, Support, and Training
SPARC Enterprise T5440 Site Planning Guide
Minimum Clearance for Service Access
Agency Compliance Specifications
Operating Environment Requirements
About the SPARC Enterprise T5440 Server
About the Cable Management Arm
Rack Compatibility Requirements
Installing the SPARC Enterprise T5440 Server
Installing the Rack Slide Assembly
Installing the Server Into the Cabinet
Installing the Cable Management Arm (CMA)
Powering On the System for the First Time
Enabling the Service Processor Network Management Port
Logging Into the Service Processor
Using the Service Processor for Common Operations
Booting the Solaris Operating System
Updating Service Processor and Server Firmware
Removing Hardware RAID Volumes
Understanding Logical Domains Software
Operating the Solaris OS With Logical Domains
ALOM-to-ILOM Command Reference
ILOM and ALOM CMT Command Comparison Tables
Understanding ILOM for the Sun SPARC Enterprise T5440 Server
Platform-Specific ILOM Features
Viewing and Configuring Host Control Information
Managing System User Interactions
Managing the Service Processor
Change Console Escape Characters (CLI)
Changing Configuration Policy Settings
Managing Virtual Keyswitch Settings
Sensors on Sun SPARC Enterprise T5440 Server
Indicators on the Sun SPARC Enterprise T5440 Server Server
Limits to Backward Compatibility
Create an ALOM CMT Compatibility Shell
ILOM and ALOM CMT Command Comparison
Event Messages Available Through the ALOM Compatibility Shell
Service Processor Usage Event Messages
Environmental Monitoring Event Messages
Host Monitoring Event Messages
Infrastructure Boards and Cables
Understanding Fault Handling Options
Connecting to the Service Processor
Displaying FRU Information With Oracle ILOM
Oracle ILOM-to-ALOM CMT Command Reference
Preparing to Service the System
Obtain the Chassis Serial Number
Obtain the Chassis Serial Number Remotely
Extending the Server to the Maintenance Position
Remove the Server From the Rack
Perform Electrostatic Discharge – Antistatic Prevention Measures
Servicing Customer-Replaceable Units
Hot-Pluggable and Hot‐Swappable Devices
Servicing Field-Replaceable Units
Servicing the Service Processor
Servicing the Power Distribution Board
Servicing the Fan Tray Carriage
Servicing the Hard Drive Backplane
Servicing the Flex Cable Assembly
Servicing the Front Control Panel
Returning the Server to Operation
Install the Server Into the Rack
Slide the Server Into the Rack
Connect the Power Cords to the Server
Performing Node Reconfiguration
I/O Connections to CMP/Memory Modules
Recovering From a Failed CMP/Memory Module
I/O Fabric in 2P Configuration
I/O Fabric in 4P Configuration
Serial Management Port Connector Pinouts
Network Management Port Connector Pinouts
Power On the System for the First Time
Log Into the Service Processor Using the Serial Management Port
Add a PCIe Card
Install a PCIe Card
Platform-Specific ILOM Features
Gigabit Ethernet Connector Pinouts
Network Management Port Connector Pinouts
Serial Management Port Connector Pinouts
Serial Port Connector Pinouts
USB Connector Pinouts
Rear Panel Cable Connections Reference
Rear Panel Cable Connections Reference
Run Full POST Diagnostics on Reset
Connect the Power Cords to the Server
Handling Electronic Components
Power Cycle the System
Infrastructure Boards and Cables
Install the Power Distribution Board
Remove the Power Distribution Board
Diagnostic Flowchart
Power On the System
POST Fault Management Overview
POST Fault Management Overview
Disabling Faulty Components Using Automatic System Recovery
POST Fault Management Flowchart
POST Parameters
Detecting Faults Using POST
Clear Faults Detected During POST
Clear Faults Detected During POST
Change POST Parameters
Run POST in Maximum Mode
Diagnostic Flowchart
Diagnostic Flowchart
About Power Supplies
Power Supply LED
Power Supply Device Identifiers
Detecting Faults Using LEDs
Install a Power Supply (Hot-Swap)
Power Off (Emergency Shutdown)
Power Off (Command Line)
Power Off (Graceful Shutdown)
Power Off (Command Line)
Power On the Server
Power On the Server
Powering On the System for the First Time
Power Cycle the System
Predictive Self-Healing Overview
Clear Faults Detected by PSH
Diagnostic Flowchart
Detecting Faults (Oracle ILOM show faulty Command)
Memory Fault Handling Overview