Site Planning

SPARC Enterprise T5440 Site Planning Guide

Physical Specifications

Minimum Clearance for Service Access

Environmental Specifications

Power Source Requirements

Acoustic Noise Emissions

Agency Compliance Specifications

Operating Environment Requirements

Installation and Setup

Preparing for Installation

About the SPARC Enterprise T5440 Server

Tools and Equipment Needed

Installation Overview

Cabling Notes

About the Slide Rail Assembly

About the Cable Management Arm

Rack Compatibility Requirements

Safety Precautions

ESD Precautions

Installing the SPARC Enterprise T5440 Server

Installing the Rack Slide Assembly

Installing the Server Into the Cabinet

Installing the Cable Management Arm (CMA)

Connecting the Server Cables

Managing Cables With the CMA

Powering On the System

Powering On the System for the First Time

Enabling the Service Processor Network Management Port

Logging Into the Service Processor

Using the Service Processor for Common Operations

Booting the Solaris Operating System

Updating the Firmware

Updating Service Processor and Server Firmware

Updating the Firmware

Selecting a Boot Device

Select a Boot Device

Administration

Basic Administrative Tasks

Initial System Setup

Communicating With the System

Performing Common Tasks

Manage Disk Volumes

Hardware RAID Support

Creating RAID Volumes

Removing Hardware RAID Volumes

Manage the System

Searching for Faults

Bypassing Minor Faults

Clearing Faults

Managing Devices

Use Logical Domains Software

Understanding Logical Domains Software

Operating the Solaris OS With Logical Domains

ALOM-to-ILOM Command Reference

ILOM and ALOM CMT Command Comparison Tables

Remote Management

Understanding ILOM for the Sun SPARC Enterprise T5440 Server

ILOM Overview

Platform-Specific ILOM Features

ILOM Features Not Supported

Managing the Host

Resetting the Host

Managing Host Boot Mode

Viewing and Configuring Host Control Information

Managing System User Interactions

Managing the Service Processor

Storing Customer Information

Display Console History (CLI)

Change Console Escape Characters (CLI)

Changing Configuration Policy Settings

Managing Network Access

Managing Devices

Managing Virtual Keyswitch Settings

IPMI Sensor Reference

Sensors on Sun SPARC Enterprise T5440 Server

Indicators on the Sun SPARC Enterprise T5440 Server Server

ALOM CMT Compatibility Shell

Limits to Backward Compatibility

Create an ALOM CMT Compatibility Shell

ILOM and ALOM CMT Command Comparison

ALOM CMT Variables

ALOM CMT Variable Comparison

Event Messages Available Through the ALOM Compatibility Shell

Event Message Overview

Event Severity Levels

Service Processor Usage Event Messages

Environmental Monitoring Event Messages

Host Monitoring Event Messages

SCC Backup and Restore

Information Stored on The SCC

Service

Identifying Server Components

Infrastructure Boards and Cables

Front Panel Diagram

Front Panel LEDs

Rear Panel Diagram

Rear Panel LEDs

Ethernet Port LEDs

Managing Faults

Understanding Fault Handling Options

Connecting to the Service Processor

Displaying FRU Information With Oracle ILOM

Controlling How POST Runs

Detecting Faults

Clearing Faults

Disabling Faulty Components

Oracle ILOM-to-ALOM CMT Command Reference

Preparing to Service the System

Safety Information

Required Tools

Obtain the Chassis Serial Number

Obtain the Chassis Serial Number Remotely

Powering Off the System

Extending the Server to the Maintenance Position

Remove the Server From the Rack

Perform Electrostatic Discharge – Antistatic Prevention Measures

Remove the Top Cover

Servicing Customer-Replaceable Units

Hot-Pluggable and Hot‐Swappable Devices

Servicing Hard Drives

Servicing Fan Trays

Servicing Power Supplies

Servicing PCIe Cards

Servicing CMP/Memory Modules

Servicing FB-DIMMs

Servicing Field-Replaceable Units

Servicing the Front Bezel

Servicing the DVD-ROM Drive

Servicing the Service Processor

Servicing the IDPROM

Servicing the Battery

Servicing the Power Distribution Board

Servicing the Fan Tray Carriage

Servicing the Hard Drive Backplane

Servicing the Motherboard

Servicing the Flex Cable Assembly

Servicing the Front Control Panel

Servicing the Front I/O Board

Returning the Server to Operation

Install the Top Cover

Install the Server Into the Rack

Slide the Server Into the Rack

Connect the Power Cords to the Server

Power On the Server

Performing Node Reconfiguration

I/O Connections to CMP/Memory Modules

Recovering From a Failed CMP/Memory Module

System Bus Topology

I/O Fabric in 2P Configuration

I/O Fabric in 4P Configuration

Identifying Connector Pinouts

Serial Management Port Connector Pinouts

Network Management Port Connector Pinouts

Serial Port Connector Pinouts

USB Connector Pinouts

Gigabit Ethernet Connector Pinouts

Server Components

Customer-Replaceable Units

Field-Replaceable Units

Index

Numbers and Symbols

A

B

C

D

E

F

G

H

I

L

M

N

O

P

Q

R

S

T

U

V

X

P

parity for serial terminal, no, Power On the System for the First Time
password command, Log Into the Service Processor Using the Serial Management Port
PCIe card
adding, Add a PCIe Card
installing, Install a PCIe Card
Physical Presence switch, Platform-Specific ILOM Features
pinouts
Gigabit Ethernet ports, Gigabit Ethernet Connector Pinouts
network management port, Network Management Port Connector Pinouts
serial management port, Serial Management Port Connector Pinouts
serial port (DB-9), Serial Port Connector Pinouts
USB ports, USB Connector Pinouts
port locations illustrated, Rear Panel Cable Connections Reference
ports, slots, and LEDs illustrated, Rear Panel Cable Connections Reference
POST diagnostics, run, Run Full POST Diagnostics on Reset
power cords
plugging into server, Connect the Power Cords to the Server
unplugging before servicing the system, Handling Electronic Components
power cycling the system, Power Cycle the System
power distribution board
about, Infrastructure Boards and Cables
installing, Install the Power Distribution Board
removing, Remove the Power Distribution Board
power off
Power Off the System
Power Off (Command Line)
Power OK (system LED), Diagnostic Flowchart
power on, Power On the System
power-on self-test (POST), POST Fault Management Overview
about, POST Fault Management Overview
components disabled by, Disabling Faulty Components Using Automatic System Recovery
configuration flowchart, POST Fault Management Flowchart
controlling output, POST Parameters
error messages, Detecting Faults Using POST
fault clearing, Clear Faults Detected During POST
faults detected by
Diagnostic Flowchart
Detecting Faults (Oracle ILOM show faulty Command)
faulty components detected by, Clear Faults Detected During POST
parameters, changing, Change POST Parameters
running in maximum mode, Run POST in Maximum Mode
troubleshooting with, Diagnostic Flowchart
using for fault diagnosis, Diagnostic Flowchart
power supply
about, About Power Supplies
AC Present LED
Diagnostic Flowchart
Power Supply LED
DC OK LED, Power Supply LED
device identifiers, Power Supply Device Identifiers
Fault LED
Detecting Faults Using LEDs
Remove a Power Supply (Hot-Swap)
Power Supply LED
Power Supply LED
hot-swapping
Install a Power Supply (Hot-Swap)
Install a Power Supply
installing
Install a Power Supply (Hot-Swap)
Install a Power Supply
removing
Remove a Power Supply (Hot-Swap)
Remove a Power Supply (Hot-Swap)
Remove a Power Supply
Power Supply Fault (system LED)
about
Front Panel LEDs
Front Panel LEDs
Power Supply LED
interpreting to diagnose faults, Detecting Faults Using LEDs
using to verify successful power supply replacement, Install a Power Supply (Hot-Swap)
powercycle command
Run POST in Maximum Mode
Oracle ILOM-to-ALOM CMT Command Reference
powering off server
emergency shutdown, Power Off (Emergency Shutdown)
from service processor prompt, Power Off (Command Line)
graceful shutdown, Power Off (Graceful Shutdown)
service processor command, Power Off (Command Line)
powering on
at service processor prompt, Power On the Server
following emergency shutdown triggered by top panel removal
Install the Top Cover
Power On the Server
using Power button, Power On the Server
powering on the system for the first time, Powering On the System for the First Time
poweroff command, Power Cycle the System
poweron command
Power On the System
Perform a Normal System Initialization
Oracle ILOM-to-ALOM CMT Command Reference
Predictive Self-Healing (PSH)
about, Predictive Self-Healing Overview
clearing faults, Clear Faults Detected by PSH
faults detected by, Diagnostic Flowchart
faults displayed by ILOM, Detecting Faults (Oracle ILOM show faulty Command)
memory faults, Memory Fault Handling Overview
PSH,, See Predictive Self-Healing (PSH)