SunVTS 3.0 Test Reference Manual

disktest Error Messages

Table 9-5 disktest Error Messages

Error Message 

Probable Cause(s) 

Recommended Action 

6000

 

Re-reading and recomparing block number on name

Media error. 

If the problem persists, call your authorized Sun service provider. 

Faulty cable, disk, or controller. 

6002

Error on recomparing block number on name

Media error. 

If the problem persists, call your authorized Sun service provider. 

Faulty cable, disk, or controller. 

6004

name failed on name, blk number: error_message

Faulty cable, disk, or controller. 

If the problem persists, call your authorized Sun service provider. 

6006

Compare error on name, block number, offset number

Faulty cable, disk, or controller. 

If the problem persists, call your authorized Sun service provider. 

6008

Compare error: Block number on name was written with a repeating hex pattern of number

Media error. 

If the problem persists, call your authorized Sun service provider. 

Faulty cable, disk, or controller. 

6010

TIME OUT!

System too busy. 

Reduce the system load. 

Faulty cable, disk, or controller. 

If the problem persists, call your authorized Sun service provider. 

6012

Couldn't close name

System error. 

 

6014

name read failed on disk, in-between blocks number and number: name

Media error. 

If the problem persists, call your authorized Sun service provider. 

Faulty cable, disk, or controller. 

6016

name read failed due to unexpected end of media

 

 

6018

name write failed on disk, in-between blocks number and number: name

Media error. 

If the problem persists, call your authorized Sun service provider. 

Faulty disk or controller. 

6020

name write failed due to unexpected end of media:

 

 

6022

name compare failed on name, block number, offset number

Media error. 

If the problem persists, call your authorized Sun service provider. 

Faulty disk or controller. 

6024

Couldn't close name

Faulty disk or controller. 

If the problem persists, call your authorized Sun service provider. 

 

 

System error. 

6026

failed automount name onto name:error_message

Un-supported file system. 

Disable the file system subtest. 

System error. 

Disable the file system subtest. 

 

If the problem persists, call your authorized Sun service provider. 

6028

error_message

 

 

8000

File system subtest only allow to run on off-line mode

Parameter error. 

Re-enter the command line correctly. 

8002

malloc() failed

System load too heavy. 

 

System error. 

 

8006

File operation error: Couldn't name file name on name: error_message

Lack of system resource. 

Reduce the system load. 

Permission error. 

Check directory or file permission. 

System error. 

If the problem persists, call your authorized Sun service provider. 

8008

Not enough free blocks on name (partition number)

 

Try another partition or delete files. 

8010

No writable partition on name

 

Try another partition. 

8012

No file system on device: name

 

Use newfs to create the file system.

Disable the file system subtest. 

8014

Couldn't run fstest on any partition of device: name(except 2)

File system not supported. 

Disable the file system subtest. 

System error. 

If the problem persists, call your authorized Sun service provider. 

8016

Cannot open device: name

Parameter error. 

Enter the correct name of disk as dev=c0t3d0.

System error. 

If the problem persists, call your authorized Sun service provider. 

8018

Couldn't mount /dev/dsk/name

Parameter error. 

Enter the correct name of disk as dev=c0t3d0.

System error. 

If the problem persists, call your authorized Sun service provider. 

8020

Couldn't remove temporary dir name: error_message

System error. 

If the problem persists, call your authorized Sun service provider. 

8022

fail get semaphore: error_message

Lack of system resource. 

Reduce the system load. 

System error. 

If the problem persists, call your authorized Sun service provider. 

8024

failed lock mtab semaphore: "semap" system call failure, errmsg error_message

disktest instances exceed system semaphore operation limitation (default system limit for seminfo_semmnu=30)system software error.

Add the line "set semsys: seminfo_semmnu=0x100" to your /etc/system file and reboot the machine. If the problem persists, call your authorized Sun service provider.

8026

fail unlock mtab semaphore: error_message

System error. 

If the problem persists, call your authorized Sun service provider. 

8028

failed get_volmgr_name()

 

 

8030

Couldn't open name: error_message

Cable loose or disconnected. 

Check the cable. 

Device off line or missing. 

Check the device on line. 

Device not configured. 

Configure the device. 

8032

Get file state name failed: error_message

System error. 

If the problem persists, call your authorized Sun service provider. 

8034

Couldn't open name

Permission error. 

Check the permissions. 

System error. 

If the problem persists, call your authorized Sun service provider. 

8036

failed putmntent(): error_message

System error. 

If the problem persists, call your authorized Sun service provider. 

8038

fail rename file

Permission error. 

Check permission. 

System error. 

If the problem persists, call your authorized Sun service provider. 

8040

Couldn't get mount table entry for name

 

 

8042

Invalid device name in name

Parameter error. 

Enter the correct name of disk as dev=c0t3d0.

8044

Message table overflow on device name

Parameter error. 

Enter the correct name of disk as dev=c0t3d0.

System error. 

If the problem persists, call your authorized Sun service provider. 

Program error. 

8046

Invalid controller id name for name

Parameter error. 

Re-enter the command line correctly. 

8048

name, disk DKIOCINFO ioctl: name

Controller is not supported. 

Disable the file system subtest. 

System error. 

If the problem persists, call your authorized Sun service provider. 

8050

failed getting shared memory for monitor number: error_message:

Lack of system resource. 

Reduce the system load. 

System error. 

If the problem persists, call your authorized Sun service provider. 

8052

failed attaching monitor shared memory:error_message

Lack of system resource. 

Reduce the system load. 

System error. 

If the problem persists, call your authorized Sun service provider. 

8053

failed create monitor shared memory number:

Lack of system resource. 

Reduce the system load. 

System error. 

If the problem persists, call your authorized Sun service provider. 

8054

Shm remove error: error_message

System error. 

If the problem persists, call your authorized Sun service provider. 

8056

New error messages in system log. Extracted below:error_message

Faulty cable/disk/controller. 

See /var/adm/messages for more information.

If the problem persists, consult your authorized Sun service provider. 

8060

fails to open any partition of name

File system not mounted. 

Mount the file system then run the test. 

Disable the file system subtest. 

If the problem persists, call your authorized Sun service provider. 

8060

failed getting semaphore: error_message

System error. 

If the problem persists, call your authorized Sun service provider. 

8062

failed getting shared memory: error_message

System error. 

If the problem persists, call your authorized Sun service provider. 

8064

failed attaching shared memory:error_message

System error. 

If the problem persists, call your authorized Sun service provider. 

8068

failed unlocking semaphore: error_message

System error. 

If the problem persists, call your authorized Sun service provider. 

8070

fail open floppy disk

No floppy disk in drive. 

Check the floppy disk. 

8072

failed FDIOGCHAR on floppy ioctl

System error. 

If the problem persists, call your authorized Sun service provider. 

8074

ioctl DKIOCGGEOM failed

File system not supported. 

If the problem persists, call your authorized Sun service provider. 

System error. 

8074

ioctl DKIOCGAPART failed

System error. 

If the problem persists, call your authorized Sun service provider. 

8076

fail initialize shared memory

System error. 

If the problem persists, call your authorized Sun service provider. 

8078

Illegal parameters on Online Mode

Parameter error. 

Enter the correct option. 

8080

Illegal parameters on Conn. Mode

Parameter error. 

Enter the correct option. 

8082

failed get_volmgr_name()

No floppy disk in drive. 

Check the floppy disk. 

8084

Mounted file system on device!

Not enough disk space. 

Reduce the system load. 

Permission error. 

Check directory or file permissions. 

System error. 

If the problem persists, call your authorized Sun service provider. 

8086

Invalid controller id number from name

Parameter error. 

Enter the correct name of disk as dev=c0t3d0.

8088

Couldn't get file system information on name errno=number

System error. 

If the problem persists, call your authorized Sun service provider. 

8090

ioctl() failed on name: name

System error. 

If the problem persists, call your authorized Sun service provider. 

8092

Fail to get disk information

No supported disk. 

No UNIX message monitor feature in this disk(2). 

System load is too heavy. 

Reduce the system load 

8094

Failed to create a message base for controller number

No disk under this controller. 

Connect the disk driver then run the test again. 

8096

fail to make directory name

Lack of system resource. 

Reduce the system load. 

Permission error. 

Check directory or file permissions. 

System error. 

If the problem persists, call your authorized Sun service provider. 

8098

Failed to mount partition

Does this disk only have partition 2. 

Partition 2 must be manually mounted. 

8010

r/w is on /dev/rname

System error. 

If the problem persists, call your authorized Sun service provider. 

8102 

write/read count error 

Out of disk space. 

Try another partition or delete some files. 

8104 

failed to create buffer 

Not enough memory. 

Reduce the system load. If the problem persists, call your authorized Sun service provider. 

8106

failed aioread() : offset error number error string

Faulty cable, disk, or controller. 

If the problem persists, call your authorized Sun service provider. 

8108

failed aiowrite() : offset error number error string

Faulty cable, disk, or controller. 

If the problem persists, call your authorized Sun service provider. 

8110 

failed io operation() : number text

Faulty cable, disk, or controller. 

If the problem persists, call your authorized Sun service provider.