Platform Notes: Using luxadm Software

Accessing the Enclosure Services Card

The env_display and various alarm subcommands apply only to an Enclosure Services Card (SES) in a RSM tray in a SPARCstorage Array. The RSM tray is addressed by using the logical or physical path of the SES device or by specifying the controller followed by the tray number. The controller is addressed by cN or the physical path to the controller in the SPARCstorage Array.

Displaying Environmental Information (env_display)

Use the env_display subcommand to display the environmental information for a SPARCstorage Array.

Supported on:


luxadm [ -v ] env_display
{ pathname | controller tray-number }

Table 2-13 env_display Options and Arguments

Option/Argument 

Description 

pathname

The path to an SES device 

controller

The path to a SPARCstorage Array controller 

tray-number

An RSM tray number. tray-number is valid only for an RSM tray in a SPARCstorage Array

Disabling the Alarm (alarm_off)

Use the alarm_off subcommand to disable the audible alarm for this enclosure. When invoked without an option, the current state of audible alarm is printed.

Supported on:


luxadm [ -v ] alarm_off { pathname | controller tray-number }

Table 2-14 alarm_off Options and Arguments

Option/Argument 

Description 

pathname

The path to an SES device 

controller

iThe path to a SPARCstorage Array controller 

tray-number

An RSM tray number. tray-number is valid only for an RSM tray in a SPARCstorage Array

Enabling the Alarm (alarm_on)

Use the alarm_on subcommand to enable the audible alarm for this enclosure. When invoked without an option, the current state of audible alarm is printed.

Supported on:


luxadm [ -v ] alarm_on { pathname | controller tray-number }

Table 2-15 alarm_on Options and Arguments

Option/Argument 

Description 

pathname

The path to an SES device 

controller

The path to a SPARCstorage Array controller 

tray-number

An RSM tray number. tray-number is valid only for an RSM tray in a SPARCstorage Array

Setting the Alarm (alarm_set)

Use the alarm_set subcommand to set the duration of the audible alarm to a specified number of seconds.

Supported on:


luxadm [ -v ] alarm_set { pathname | controller tray-number } [seconds]

Table 2-16 alarm_set Options and Arguments

Option/Argument 

Description 

pathname

The path to an SES device 

controller

The path to a SPARCstorage Array controller 

tray-number

An RSM tray number. tray-number is valid only for an RSM tray in a SPARCstorage Array

seconds

The number of seconds