After physically inserting a board in the card cage, logically connect the board:
# cfgadm -c connect sysctrl#:slot#
sysctrl#:slot# is the logical attachment point identification (the system name for the board), which can be found in the cfgadm status display.
The states and conditions for the attachment point before a board is inserted are:
Receptacle state--Empty
Occupant state--Unconfigured
Condition--Unknown
After a board is physically inserted, the states and conditions are:
Receptacle state--Disconnected
Occupant state--Unconfigured
Condition--Unknown
After the attachment point is logically connected, the states and conditions are:
Receptacle state--Connected
Occupant state--Unconfigured
Condition--OK
Now the system is aware of the board, but not the usable devices which reside on the board. Temperature is monitored and power and cooling affect the attachment point condition.