Download the latest version of command line interface SUNWsccli package and install it on the management station.
Run the following command to connect to the 3510 with an interactive prompt:
# sccli amer-minnow-01 sccli: selected se3000://172.31.0.141:58632 [SUN StorEdge 3510 SN#084DCD] |
Set Chassis ID on each controller and JBOD as shown in Figure 2–1 and verify you can see all disks by running show disks command.
Verify the following parameters:
|
Controller parameters |
redundancy mode |
active-active |
|
redundancy status |
enabled |
|
|
Drive parameters |
auto-global-spare |
enabled |
|
Host parameters |
fiber connection mode |
point-to-point (SAN) |
|
controller name |
amer-minnow-nn |
|
|
Cache policy |
mode |
write-back |
|
optimization |
sequential |
sccli> show redundancy-mode
Primary controller serial number: 8040703
Redundancy mode: Active-Active
Redundancy status: Enabled
Secondary controller serial number: 8040608
sccli> show drive-parameters
spin-up: disabled
reset-at-power-up: enabled
disk-access-delay: 15s
scsi-io-timeout: 30s
queue-depth: 32
polling-interval: 0ms
enclosure-polling-interval: 30s
auto-detect-swap-interval: 0ms
smart: disabled
auto-global-spare: disabled
sccli> set drive-parameters auto-global-spare enabled
sccli> set controller amer-minnow-01
sccli> show controller
controller-name: "amer-minnow-01"
sccli> show host-parameters
max-luns-per-id: 32
queue-depth: 1024
fibre connection mode: point to point
sccli> show cache-policy
mode: write-back
optimization: sequential
|
Gather the WWNs of the minnows and add them to zones accordingly:
sccli>show port-wwns
Ch Id WWPN
-------------------------
0 40 216000C0FF884DCD
1 42 226000C0FFA84DCD
4 44 256000C0FFC84DCD
5 46 266000C0FFE84DCD
sccli> show ses
Ch Id Chassis Vendor/Product ID Rev PLD WWNN
WWPN Topology:
-------------------------------------------------------------
---------------------------
2 12 084DCD SUN StorEdge 3510F A 1040 1000 204000C0FF084DCD
214000C0FF084DCD loop(a)
2 28 08036B SUN StorEdge 3510F D 1040 1000 205000C0FF08036B
215000C0FF08036B loop(a)
2 44 07D493 SUN StorEdge 3510F D 1040 1000 205000C0FF07D493
215000C0FF07D493 loop(a)
3 12 084DCD SUN StorEdge 3510F A 1040 1000 204000C0FF084DCD
224000C0FF084DCD loop(b)
3 28 08036B SUN StorEdge 3510F D 1040 1000 205000C0FF08036B
225000C0FF08036B loop(b)
3 44 07D493 SUN StorEdge 3510F D 1040 1000 205000C0FF07D493
225000C0FF07D493 loop(b)
|