Download the latest version of command line interface SUNWsccli package and install it on the management station.
Run the following command to connect to the 3510 with an interactive prompt:
# sccli amer-minnow-01 sccli: selected se3000://172.31.0.141:58632 [SUN StorEdge 3510 SN#084DCD] |
Set Chassis ID on each controller and JBOD as shown in Figure 2–1 and verify you can see all disks by running show disks command.
Verify the following parameters:
Controller parameters |
redundancy mode |
active-active |
redundancy status |
enabled |
|
Drive parameters |
auto-global-spare |
enabled |
Host parameters |
fiber connection mode |
point-to-point (SAN) |
controller name |
amer-minnow-nn |
|
Cache policy |
mode |
write-back |
optimization |
sequential |
sccli> show redundancy-mode Primary controller serial number: 8040703 Redundancy mode: Active-Active Redundancy status: Enabled Secondary controller serial number: 8040608 sccli> show drive-parameters spin-up: disabled reset-at-power-up: enabled disk-access-delay: 15s scsi-io-timeout: 30s queue-depth: 32 polling-interval: 0ms enclosure-polling-interval: 30s auto-detect-swap-interval: 0ms smart: disabled auto-global-spare: disabled sccli> set drive-parameters auto-global-spare enabled sccli> set controller amer-minnow-01 sccli> show controller controller-name: "amer-minnow-01" sccli> show host-parameters max-luns-per-id: 32 queue-depth: 1024 fibre connection mode: point to point sccli> show cache-policy mode: write-back optimization: sequential |
Gather the WWNs of the minnows and add them to zones accordingly:
sccli>show port-wwns Ch Id WWPN ------------------------- 0 40 216000C0FF884DCD 1 42 226000C0FFA84DCD 4 44 256000C0FFC84DCD 5 46 266000C0FFE84DCD sccli> show ses Ch Id Chassis Vendor/Product ID Rev PLD WWNN WWPN Topology: ------------------------------------------------------------- --------------------------- 2 12 084DCD SUN StorEdge 3510F A 1040 1000 204000C0FF084DCD 214000C0FF084DCD loop(a) 2 28 08036B SUN StorEdge 3510F D 1040 1000 205000C0FF08036B 215000C0FF08036B loop(a) 2 44 07D493 SUN StorEdge 3510F D 1040 1000 205000C0FF07D493 215000C0FF07D493 loop(a) 3 12 084DCD SUN StorEdge 3510F A 1040 1000 204000C0FF084DCD 224000C0FF084DCD loop(b) 3 28 08036B SUN StorEdge 3510F D 1040 1000 205000C0FF08036B 225000C0FF08036B loop(b) 3 44 07D493 SUN StorEdge 3510F D 1040 1000 205000C0FF07D493 225000C0FF07D493 loop(b) |