System Administration Guide: IP Services

How to Configure a Multipathing Group With One of the Interfaces a Standby Interface

The examples that are used in this procedure assume that hme1 will be configured as the standby interface.


Note –

A standby interface has only a test address.


  1. Do steps 1 and 2 in How to Configure a Multipathing Interface Group With Two Interfaces.

  2. Configure the test address on all physical interfaces by using the following substeps.

    1. For the non-standby interface, such as hme0, do step 3 in How to Configure a Multipathing Interface Group With Two Interfaces.

    2. For a standby interface, configure a test address by typing the following command.


      Note –

      A standby interface can have only a test address. A standby interface cannot have any other IP address.



      # ifconfig interface-name plumb ip-address <other-parameters> deprecated -failover 
      standby up

      Note –

      You must set the -failover option before the standby option and the standby option before up.


      For <other-parameters>, use the parameters that are required by your configuration. See the ifconfig(1M) man page for descriptions.

      For example, to create a test address with the following configuration:

      • Physical interface hme1 as a standby interface

      • Address of 19.16.85.22

      • With deprecated and -failover set

      • Sets the netmask and broadcast address to the default value

      You type the following command:


      # ifconfig hme1 plumb 19.16.85.22 netmask + broadcast + deprecated -failover standby up

      You can check the results by typing the following:


      # ifconfig hme1
      flags=69040843<UP,BROADCAST,RUNNING,MULTICAST,DEPRECATED,IPv4,NOFAILOVER,STANDBY,INACTIVE> 
              mtu 1500 index 4 inet 19.16.85.22 netmask ffffff00 broadcast 19.16.85.255
              groupname test

      For IPv6, to create a test address, type the following command:


      ifconfig hme1 plumb -failover standby up

    The INACTIVE flag indicates that this interface is not used for any outbound packets. When a failover occurs on this standby interface, the INACTIVE flag is cleared.

  3. (Do this step only if you want to preserve the configuration across reboots.) To preserve the configuration across reboots, do the following substeps.

    • For IPv4, edit the /etc/hostname.interface file and add the following line.


      interface-address <parameters> group group-name up \
      	addif logical-interface-failover deprecated <parameters> up

      Note –

      This test IP address is configured only on the next reboot. If you want the configuration to be invoked in the current session, do steps 1 and 2.


      For example, to create a group test with the following configuration for hme0:

      • Physical interface hme0 with address 19.16.85.19

      • A logical interface address of 19.16.85.21

      • With deprecated and -failover set

      • Sets the netmask and broadcast address to the default value

      You add the following line to the /etc/hostname.hme0 file:


      19.16.85.19 netmask + broadcast + group test up \
      	addif 19.16.85.21 deprecated -failover netmask + broadcast + up

      Similarly, to place the standby interface hme1 under the same group test and configure a test address, type the following command:


      19.16.85.22 netmask + broadcast + deprecated group test -failover standby up 
    • For IPv6, edit the /etc/hostname6.interface file and add the following line.


      -failover group group-name up

      Note –

      This test IP address is configured only on the next reboot. If you want the configuration to be invoked in the current session, do steps 1 and 2.


      For example, to create a test group for hme0 with an IPv6 address, add the following line to the /etc/hostname6.hme0 file:


      -failover group test up

      Similarly, to place the standby interface hme1 under the same group test and configure a test address, add the following line to the /etc/hostname6.hme1 file:


      -failover group test standby up