System Administration Guide: Basic Administration

x86: Troubleshooting PCI Configuration Problems

Error Message

cfgadm: Configuration operation invalid: invalid transition
Cause

An invalid transition was attempted.

Solution

Check whether the cfgadm -c command was issued appropriately. Use the cfgadm command to check the current receptacle and occupant state and to make sure that the Ap_Id is correct.

Error Message

cfgadm: Attachment point not found
Cause

The specified attachment point was not found.

Solution

Check whether the attachment point is correct. Use the cfgadm command to display a list of available attachment points. Also check the physical path to see if the attachment point is still there.


Note –

In addition to the cfgadm command, several other commands are helpful during hot-pluggable operations. The prtconf command displays whether Solaris recognizes the hardware. After adding hardware, use the prtconf command to verify that the hardware is recognized. After a configure operation, use the prtconf -D command to verify that the driver is attached to the newly installed hardware device.