Card Placement and Cooling

If you are using the Sun Flash Accelerator F20 PCIe card, your configuration must meet the following requirements for proper installation and cooling:

  • Do not connect devices to the internal SAS/SATA ports of the Sun Flash Accelerator F20 PCIe card. The Sun Fire X4470 does not support using this card as an internal host bus adapter (HBA).

  • The HBA can be installed only in PCIe slots 9, 4, 8, 7, or 6, in that order of preference (slot 9 is the preferred slot to use for this HBA and slot 6 is acceptable but is the least desirable slot to use).


    Note -  If you are using a Sun Storage 6Gb SAS PCIe RAID HBA, that HBA must be installed in slot 4; therefore, slot 4 will not be available for the Sun Flash Accelerator F20 PCIe card.
  • If you are using the Sun Flash Accelerator F20 PCIe card, you must use the Oracle Integrated Lights Out Manager (ILOM) available with Software Release 1.2.1 or later.

  • With this HBA installed only in slots 9 and/or 4, the ambient temperature requirement for the server remains as follows:

    • Operating temperature: 5 oC to 35 oC (41 oF to 95 oF)

    • Nonoperating temperature: -40 oC to 70 oC (-40 oF to 158 oF)

  • With this HBA installed in slot 8, slot 7, or slot 6, the ambient temperature requirement for the server is modified to the following:

    • Operating temperature: 5 oC to 32 oC (41 oF to 89.6 oF)