Cannot Detect the HBA on the Sun Blade T6300 System (6680542)

After swapping between different types of HBAs on a Sun Blade T6300 system, the system might not be able to detect the Sun StorageTek Dual 4 Gb FC Dual GbE HBA.

Workaround - Reboot the system.


The PEM Might Not Come Online on a Sun Blade T6300 or T6320 System (6683536)

In rare circumstances, after a Sun Blade T6300 or T6320 system has gone through several reboots, the Pluggable Express Module (PEM) on the system might not come online. With this PEM offline, the system cannot detect all devices that are connected to the system.

Workaround - Reboot the system again, which enables the PEM service to come back online.


Cannot Detect the HBA Through the BIOS on the Sun Blade X8450 System (6704510)

If the Sun Blade X8450 system has an ILOM version prior to 2.0.1.10, the BIOS might not be able to detect the HBA.

Workaround - Upgrade to the ILOM version 2.0.1.10 or later.


Cannot Verify the FCode Version of the HBA on the Sun Blade T6300 and T6320 Systems (6686545)

The FCode version is not displayed when you use the luxadm fcode -p command.

Workaround - You can verify the FCode version at the ok prompt.