Sun StorEdge D240 Media Tray Release Notes

This document contains the following topics:


Product Changes

The Sun StorEdgetrademark D240 media tray is now supported with the following additional features:


System Requirements

The Sun StorEdge D240 media tray supports a variety of Sun servers. TABLE 1 shows the Sun servers supported by the D240 Media Tray.


TABLE 1 Supported Servers

Sun Blade 1000

Sun Fire T2000

Sun Blade 1500

Sun Fire 280R server

Sun Blade 2000

Netra 20 server

Sun Blade 2500

Netra 240 server

Sun Fire 3800 server

Netra 440 server

Sun Fire 4800 server

Netra 1280 server

Sun Fire V120 server

Netra 120 server

Sun Fire V1280 server

Sun Fire 4810 server

Sun Fire V210 server

Sun Fire 12000 server

Sun Fire V240 server

Sun Fire 15000 server

Sun Fire V250 server

Sun Fire E2900 server

Sun Fire V440 server

Sun Fire E4900 server

Sun Fire V480 server

Sun Fire E6900 server

Sun Fire V490 server

Sun FireE20000 server

Sun Fire V880 server

Sun Fire E25000 server

Sun Fire V890 server

 


TABLE 2 shows the HBAs, servers, onboard connection options, and cables supported for use with the D240 Media Tray. All the cables listed are RoHS cables.


TABLE 2 HBAs, Servers, and Cables Supported for Use with D240

Host Bus Adapters

Servers

Cables

SG-XPCI1SCSI-LM320 PCI Single-channel, Ultra320 LVD SCSI HBA (320MB/sec)

Sun Fire T2000

X1132A-Z (.8m SCSI-3/VHDCI SCSI cable)

X3832A-Z (2m SCSI-3/VHDCI SCSI cable)

X3830A-Z (4m SCSI-3/VHDCI SCSI cable)

X3831A-Z (10m SCSI-3/VHDCI SCSI cable)

SG-XPCI2SCSI-LM320[1] PCI Dual-channel, Ultra320 LVD SCSI HBA (320MB/sec)

Sun Blade 1000, 1500, 2000, 2500

Sun Fire 280R, V120, V210, V240, V250, V440, V480, V490, V880, V890, V1280

Sun Fire 4800, 6800, 12K, 15K

Sun Fire Enterprise 2900, 4900, 6900, 20K, 25K

Netra 20, 120, 240, 440, 1280

X1132A-Z (.8m SCSI-3/VHDCI SCSI cable)

X3832A-Z (2m SCSI-3/VHDCI SCSI cable)

X3830A-Z (4m SCSI-3/VHDCI SCSI cable)

X3831A-Z (10m SCSI-3/VHDCI SCSI cable)

 

X4422A-2 PCI Dual-channel, Ultra2 LVD SCSI HBA (80MB/sec) / Dual-ethernet 10/100/1000 (RoHS compliant)

Sun Fire 280R, V120, V210, V240, V440, V480, V490

Sun Fire 4800, 4810, 6800

Sun Fire Enterprise 4900, 6900, 20K, 25K

Netra 440

X1132A-Z (.8m SCSI-3/VHDCI SCSI cable)

X3832A-Z (2m SCSI-3/VHDCI SCSI cable)

X3830A-Z (4m SCSI-3/VHDCI SCSI cable)

X3831A-Z (10m SCSI-3/VHDCI SCSI cable)

 

X2222A[2] PCI Dual-channel, Ultra2 LVD SCSI HBA (80MB/sec) / Dual-ethernet 10/100

Sun Fire 280R, V120, V210, V240, V480, V490

Sun Fire 4800, 4810, 6800, 12K, 15K

Sun Fire Enterprise 4900, 6900, 20K, 25K

X1132A-Z (.8m SCSI-3/VHDCI SCSI cable)

X3832A-Z (2m SCSI-3/VHDCI SCSI cable)

X3830A-Z (4m SCSI-3/VHDCI SCSI cable)

X3831A-Z (10m SCSI-3/VHDCI SCSI cable)

X6540A[3] PCI Dual-channel, Single-ended, Ultra SCSI HBA (40MB/sec)

Sun Fire 280R

X1132A-Z (.8m SCSI-3/VHDCI cable)

X3832A-Z (2m SCSI-3/VHDCI cable)

X1232A[4] PCI Single-channel, Single-ended Ultra SCSI HBA (40MB/sec) / Ethernet 10/100

Sunfire 3800

X1134A-Z (.8m SCSI-3/SCSI-3 cable)

X1139A-Z (2m SCSI-3/SCSI-3 cable)

X3810A-Z (4m SCSI-3/SCSI-3 cable)

X1032A PCI Single-channel, Single-ended Ultra SCSI HBA (40MB/sec) / Ethernet 10/100

Sun Fire V440

Sun Fire 4800, 4810, 6800

X1134A-Z (.8m SCSI-3/SCSI-3 cable)

X1139A-Z (2m SCSI-3/SCSI-3 cable)

X3810A-Z (4m SCSI-3/SCSI-3 cable)

Onboard SCSI Ports (LVD)

Sun Fire V210, V240

X1132A-Z (.8m SCSI-3/VHDCI SCSI cable)

X3832A-Z (2m SCSI-3/VHDCI SCSI cable)

X3830A-Z (4m SCSI-3/VHDCI SCSI cable)

X3831A-Z (10m SCSI-3/VHDCI SCSI cable)

Sun Fire V120, V440

X1134A-Z (.8m SCSI-3/SCSI-3 cable)

X1139A-Z (2m SCSI-3/SCSI-3 cable)

X3810A-Z (4m SCSI-3/SCSI-3 cable)

X3839A-Z (10m SCSI-3/SCSI-3 cable)




Note - Each D240 Media Tray ships with two cables: one X3832A-Z 2m SCSI-3/VHDCI SCSI cable, and one X1139A 2m SCSI-3/SCSI-3 cable.




procedure icon  To Configure the Storage Subsystem Manager Software with the Name of the Sun StorEdge D240 Media Tray

This procedure is optional. It changes only the name of the media tray, which displays in messages from the software.

1. If the Storage Subsystem Manager software is running, stop it.


# /etc/init.d/ssmgmt stop

2. Change to the /etc/opt/SUNWssm directory.


# cd /etc/opt/SUNWssm

3. Use the editor of your choice to change "D130" to "D240" or to "D130/D240" in the STORAGE NAME variable in the ssmon.conf file.


# vi ssmon.conf

4. Start the Storage Subsystem Manager software.


# /etc/init.d/ssmgmt start


Release Documentation

The Sun StorEdge D240 media tray documentation is available at http://www.sun.com/products-n-solutions/hardware/docs/
Network_Storage_Solutions/Boot/D240/index.html.


Service Contact Information

If you need help installing or using this product, call 1-800-USA-4SUN, or go to
http://www.sun.com/service/contacting.


1 (TableFootnote) The SG-XPCI2SCSI-LM320 is supported, but is now replaced by the SG-XPCI2SCSI-LM320Z.
2 (TableFootnote) HBA X2222A ships without cables.
3 (TableFootnote) HBA X6540A ships with two X3832AZ cables. When installed on a Sun Fire 280R, it supports only one D240 Media Tray per HBA.
4 (TableFootnote) HBAs X1032A and X1232A are supported but are no longer available for purchase from Sun.