Sun LSI 106x RAID User’s Guide
For LSI-based Controllers That Support Integrated RAID
820-4933-15
|
Contents |
Part I BIOS RAID Configuration Utility
1. Introduction to Integrated RAID
Does Your LSI Controller Support Integrated RAID?
2. Overview of Integrated Mirroring and Integrated Mirroring Enhanced
Re-synchronization with Concurrent Host I/O Operation
3. Creating IM and IME Volumes
Creating a Second IM or IME Volume

To Create a Second IM or IME Volume

To Create Global Hot-Spare Disks
Locating a Disk Drive or Multiple Disk Drives in a Volume
4. Overview of Integrated Striping
5. Creating Integrated Striping Volumes

To Create a Second IS Volume, Method I

To Create a Second IS Volume, Method II
Locating a Disk Drive or Multiple Disk Drives in a Volume
Common Command-Line Parameters
Monitoring and Managing RAID Arrays

To View the Status of a RAID1 Volume
Part III MegaRAID Storage Manager
7. MegaRAID Storage Manager (MSM) Installation
Installing MSM on the Windows OS

To Install MSM on the Windows OS
Windows Installation Error Messages

To Install MSM on the Linux OS

To Create a Partition and Filesystem on Linux OS
8. Using MegaRAID Storage Manager

To Start MSM on the Windows 2003 Server

To Start MSM on a RHEL 4 Server

To Start MSM on a SLES 10 Server

To Access Servers on Alternate Subnets
Properties/Operations/Graphical View Panel
Using the MSM RAID Configuration Wizard

To Start the MSM RAID Configuration Wizard

To Create a RAID Partition and File System (Windows 2003)
Changing Virtual Disk Properties

To Change a Virtual Disk Property
Saving a Storage Configuration to Disk
Clearing a Storage Configuration From a Controller

To Clear a Configuration from a Controller
Monitoring System Events and Storage Devices

To Display All Controller Information

To Display Complete Disk Drive Information

To Display a Graphical View of a Disk Drive

To Display a Graphical View of a Virtual Disk
Monitoring Rebuilds and Other Processes
Maintaining and Managing Storage Configurations

To Rebuild a Drive on a SAS IR System
Putting a Drive Offline or Missing

To Put a Drive Offline or Missing
Sun Fire X4100 M2 /X4200 M2 Server Issues
(Windows 2003 Server) MSM-IR 1.19 Does Not Reflect Correct Disk Count Information (CR 6514389)
Sun Fire X4600 M2 Server Issues
MSM-IR 1.19 Does Not Show Disk Removal Status Correctly in a Non-RAID Configuration (CR 6525255)
MSM Server and Client Must Be in Same Subnet (6533271)
Sun Blade X6240, X6440 Server Issues
Locate Virtual Disk Function Does Not Light LEDs on Disks Controlled by Server Blade (CR 6732326)
MSM "Prepare For Removal" Operation Fails in Windows 2003, 2008 (CR 6747581) for Disks in Disk Blade
Installing and Configuring SNMP Service

To Install the SNMP Service on the Server Side on Windows Server 2003

To Configure the SNMP Service on the Server Side on Windows Server 2003
Installing and Configuring the SNMP Server on the Server Side on Linux
Installing LSI SNMP on a Remote Station

To Download the LSI SNMP Agent Files

To Install SNMP Files on a Remote Station
Part IV P A R T IV - Using raidctl With Solaris OS
Using raidctl to Create RAID Volumes
Obtaining Disk Names in Canonical Format
Obtaining Disk Names in C.ID.L Format
Copyright © 2006, 2007 by LSI Logic Corporation. All rights reserved. © 2009 Sun Microsystems, Inc. All rights reserved.