Sun Fire X4170, X4270, and X4275 Servers Service Manual
820-5830-13
Contents |
1. Sun Fire X4170, X4270, and X4275 Servers Overview
1.3 Sun Fire X4170, X4270, and X4275 Servers Front Panel Features
1.4 Sun Fire X4170, X4270, and X4275 Servers Back Panel Features
2. Preparing to Service the System
2.3 Obtaining the Chassis Serial Number
2.4 Powering On and Off the Server
2.4.3 Power Off the Server Using the Service Processor Command-Line Interface
2.5 Wake On LAN-Remote Power On
2.5.2 Enable or Disable WOL in BIOS
2.6 Configuring Support for TPM
2.7 Extending the Server to the Maintenance Position
2.7.1 Extend the Server to the Maintenance Position
2.8 Removing the Server From the Rack
2.8.1 Remove Server From the Rack
2.9 Performing Electrostatic Discharge and Antistatic Prevention Measures
2.9.1 Electrostatic Discharge Safety Measures
2.9.1.1 Using an Antistatic Wrist Strap
2.9.1.2 Using an Antistatic Mat
2.9.2 Use ESD Handling Precautions
2.10.1 Remove Top Cover From Sun Fire X4170 and X4270 Servers
2.10.2 Remove Top Cover From Sun Fire X4275 Server
3. Servicing Customer-Replaceable Devices
3.1 Hot-Pluggable Versus Hot-Swappable Devices
3.2.1 Server Storage Drive Locations
3.2.2 Storage Drive Status LED Reference
3.3.2 Fan Module LED Reference
3.3.3 Detecting Fan Module Failure
3.4.1 Detecting Power Supply Failure
3.4.2 Power Supply LED Reference
4. Servicing Motherboard Components
4.1 Servicing Memory Modules (DIMMs)
4.1.1 DIMM and CPU Physical Layout
4.1.3 DIMM Rank Classification Labels
4.1.4 Locations of Faulty DIMMs Using ILOM Versus BIOS
4.1.7 Error Correction and Parity
4.2 Servicing the Air Baffle on Sun Fire X4270 and X4275 Servers
4.3.1 Remove PCIe Riser From Sun Fire X4170 Server
4.3.2 Install PCIe Riser on Sun Fire X4170 Server
4.3.3 Remove PCIe Riser From Sun Fire X4270 and X4275 Servers
4.3.4 Install PCIe Riser on Sun Fire X4270 and X4275 Servers
4.4.1 PCIe Card Configuration Guidelines
4.4.2 Remove PCIe Card From Sun Fire X4170 Server
4.4.3 Install PCIe Card on Sun Fire X4170 Server
4.4.4 Remove PCIe Cards From Sun Fire X4270 and X4275 Servers
4.4.5 Install PCIe Cards on Sun Fire X4270 and X4275 Servers
4.7 Servicing the Motherboard Assembly
4.7.1 Remove Motherboard Assembly
4.7.2 Install Motherboard Assembly
4.8 Resetting Passwords and Clearing CMOS NVRAM
4.8.2 Reset the BIOS Password and Clear the CMOS NVRAM Using the CLR CMOS Button
5. Servicing Sun Fire X4170 and X4270 Servers Infrastructure Boards and Components
5.1 Servicing the DVD/USB Module
5.2 Servicing the Fan Power Boards
5.3 Servicing the Storage Drive Cage
5.3.1 Remove Storage Drive Cage
5.3.2 Install Storage Drive Cage
5.4 Servicing the Storage Drive Backplane
5.4.1 Remove Storage Drive Backplane
5.4.2 Install Storage Drive Backplane
5.5 Servicing the Front Control Panel Light Pipe Assembly
5.5.1 Remove Front Control Panel Light Pipe Assembly
5.5.2 Install Front Control Panel Light Pipe Assembly
5.6 Servicing the Power Distribution Board
5.6.1 Remove Power Distribution Board From Sun Fire X4170 Server
5.6.2 Install Power Distribution Board on Sun Fire X4170 Server
5.6.3 Remove Power Distribution Board From the Sun Fire X4270 Server
5.6.4 Install Power Distribution Board on the Sun Fire X4270 Server
5.7.1 Remove Paddle Card From Sun Fire X4170 Server
5.7.2 Install Paddle Card on Sun Fire X4170 Server
5.7.3 Remove Paddle Card From Sun Fire X4270 Server
5.7.4 Install Paddle Card on Sun Fire X4270 Server
5.8.1 Remove HDD Cables in a SAS Configuration
5.8.2 Install HDD Cables in a SAS Configuration on Sun Fire X4170 Server
5.8.3 Install HDD Cables in a SAS Configuration on Sun Fire X4270 Server
5.8.4 Remove HDD Cables in a SATA Configuration (Sun Fire X4170 Server Only)
5.8.5 Install HDD Cables in a SATA Configuration (Sun Fire X4170 Server Only)
5.8.6 Change HDD Cables From SAS to SATA (Sun Fire X4170 Server Only)
5.8.7 Change HDD Cables From SATA to SAS (Sun Fire X4170 Server Only)
5.8.8 Remove Power Distribution Board Cable
5.8.9 Install Power Distribution Board Cable
6. Servicing Sun Fire X4275 Server Infrastructure Boards and Components
6.1 Servicing the Fan Power Board
6.1.1 Remove Fan Power Board From Sun Fire X4275 Server
6.1.2 Install Fan Power Board on Sun Fire X4275 Server
6.2 Servicing the Storage Disk Expander Card
6.2.1 Removing the Sun Fire X4275 Server Storage Disk Expander Card
6.2.2 Install Storage Disk Expander Card on Sun Fire X4275 Server
6.3 Servicing the Storage Drive Backplane
6.3.1 Remove Storage Drive Backplane From Sun Fire X4275 Server
6.3.2 Install Storage Drive Backplane on Sun Fire X4275 Server
6.4 Servicing the Front Control Panel Light Pipe Assembly From Sun Fire X4275 Server
6.4.1 Remove Front Control Panel Light Pipe Assembly From the Sun Fire X4275 Server
6.4.2 Install Front Control Panel Light Pipe Assembly on Sun Fire X4275 Server
6.5 Servicing the Power Distribution Board
6.5.1 Remove Power Distribution Board From Sun Fire X4275 Server
6.5.2 Install Server Power Distribution Board on the Sun Fire X4275 Server
6.6 Servicing the Connector Break Out Board
6.6.1 Remove Connector Break Out Board From Sun Fire X4275 Server
6.6.2 Install Connector Break Out Board on Sun Fire X4275 Server
6.7.1 Remove Storage Drive Cable in a SAS Configuration From Sun Fire X4275 Server
6.7.2 Install Storage Drive Cable in a SAS Configuration on Sun Fire X4275 Server
6.7.3 Remove Power Distribution Board Cable From Sun Fire X4275 Server
6.7.4 Install Power Distribution Board Cable on Sun Fire X4275 Server
7. Returning the Server to Operation
7.2 Reinstalling the Server in the Rack
7.2.1 Reinstall Server in Rack
7.3 Returning the Server to the Normal Rack Position
7.3.1 Return the Server to the Normal Rack Position
8. Troubleshooting The Server and Restoring ILOM Defaults
8.1 Troubleshooting The Server
8.1.2 Diagnostic Tool Documentation
8.2.1 Accessing the Preboot Menu
8.2.1.1 Prerequisites for Accessing the Preboot Menu
8.2.1.2 Access to the Preboot Menu
8.2.1.3 Edit Preboot Menu for Remote Access
8.2.1.4 Edit Mode Settings in Preboot Menu.
8.2.2 Restoring the Factory Default ILOM Root Password
8.2.2.1 Restore ILOM Root Password to Factory Default Using the Preboot Menu
8.2.3 Restoring ILOM Access to the Serial Console
8.2.3.1 Restore Access to the Serial Console Using the Preboot Menu
8.2.4 Restoring the SP Firmware Image
8.2.4.1 Prerequisite for Restoring SP Firmware Using Preboot Menu
8.2.4.2 Special Recovery Considerations for Systems Running ILOM Firmware 2.0.2.17 or Later
8.2.4.3 Restore the SP Firmware Image Using the Preboot Menu
8.2.5 Preboot Menu Command Summary
A.1 Serial Management Port Connector
A.2 Network Management Port Connector
A.5 Gigabit-Ethernet Connectors
B. Sun Fire X4170 Server Illustrated Parts Breakdown
B.1 Sun Fire X4170 Server Components
C. Sun Fire X4270 Server Illustrated Parts Breakdown
C.1 Sun Fire X4270 Server Components
D. Sun Fire X4275 Server Illustrated Parts Breakdown
D.1 Sun Fire X4275 Server Components
E.1 Using BIOS Setup Utility Menu Items
E.2 BIOS Setup Screens Overview
E.3 BIOS Setup Utility Menu Screens
E.3.2 BIOS Advanced Menu Screens
E.3.5 BIOS Security Menu Screens
E.3.6 BIOS Chipset Menu Screens
E.4 Default BIOS Power-On Self-Test (POST) Events
E.5 BIOS POST F1 and F2 Errors
E.6 Ethernet Port Device and Driver Naming
Copyright © 2010, Oracle and/or its affiliates. All rights reserved.