C H A P T E R  3

Sun Storage J4200/J4400 Specifications

This chapter describes the physical, environmental, and electrical requirements for the Sun Storage J4200/J4400 arrays. Where information for both arrays is the same, a single table is used. This chapter contains the following sections:


Dimension and Weight Specifications

The floor space at the installation site must be strong enough to support the combined weight of the cabinet, controller trays, expansion trays, and associated equipment. The site also requires sufficient space for installation, operation, and servicing the arrays and sufficient ventilation to provide a free flow of air to the unit.

The total weight of an expansion tray depends on the number of drives installed.

TABLE 3-1 provides the physical dimensions and weight of the J4200 and the J4400 arrays.


TABLE 3-1 Dimensions and Weight (with rails)

Height

Width

Depth

Weight (Fully Populated)

J4200

 

 

 

3.44 in.

17.52 in.

24.05 in.

59.61 lb.

8.74 cm

44.5 cm

61.1 cm

27.04 kg

J4400

 

 

 

6.88 in.

17.5 in.

23.4 in.

103.20 lbs

17.48 cm

44.5 cm

59.4 cm

46.81 kg



Environmental Requirements

This section describes the environmental conditions that are prerequisite to installing the unit, and heat conditions that are generated by normal operation of the unit.

J4200 Temperature lists the temperature specifications in which the J4200 array is designed to operate, and J4400 Temperature lists the temperature specifications in which the J4400 array is designed to operate.

TABLE 3-2 J4200 Temperature

Parameter

Specification

Operating range

35˚ F to 95˚ F (0˚ C to 35˚ C)

Maximum rate of change

18˚ F (10˚ C) per hour

Storage range

-40˚ F to 149˚ F (-40˚ C to 65˚ C)

Maximum rate of change

27˚ F (15˚ C) per hour

Transit range

-40˚ F to 149˚ F (-40˚ C to 65˚ C)

Maximum rate of change

27˚ F (15˚ C) per hour

Heat output1

352.8 Watts (1204 BTU/hour)


TABLE 3-3 J4400 Temperature

Operating range

35˚ F to 95˚ F (0˚ C to 35˚ C)

Maximum rate of change

18˚ F (10˚ C) per hour

Storage range

-40˚ F to 149˚ F (-40˚ C to 65˚ C)

Maximum rate of change

27˚ F (15˚ C) per hour

Transit range

-40˚ F to 149˚ F (-40˚ C to 65˚ C)

Maximum rate of change

27˚ F (15˚ C) per hour

Heat output2

662 Watts (2123 BTU/hour)


1 Based on a configuration of two power supplies, two SIMs, two fan modules, and 12 drives.

2 Based on a configuration of two power supplies, two SIMs, and 24 drives.

Humidity

Table shows the operating temperature, relative humidity, altitude, shock, vibration, and heat output ranges of the array trays.

J4200/J4400 Relative Humidity (noncondensing) lists the relative humidity of the J4200/J4400 array.

TABLE 3-4 J4200/J4400 Relative Humidity (noncondensing)

Parameter

Specification

Operating range

20% to 80%

Nonoperating range

20% to 95%

Storage range

20% to 95%

Transit range

20% to 95%

Maximum dew point

26˚ C (79˚ F)

Maximum gradient

10% per hour


Altitude

J4200/J4400 Altitude lists the altitude specifications for the J4200/J4400 array.

TABLE 3-5 J4200/J4400 Altitude

Environment

Specification

Operating

0 to 9,843 feet (3,000 meters)

Non-operating

0 to 39,370 feet (12,000 meters)


Vibration and Shock

J4200 Shock and Vibration lists the vibration and shock specifications for the J4200 array, and J4400 Shock and Vibration lists the vibration and shock specifications for the J4400 array.

TABLE 3-6 J4200 Shock and Vibration

Condition

Parameter

Specification

Vibration

Operating

0.25 G (peak), 3 to 200 Hz sweep @ 1/2 octave per minute, bottom side tested only

Nonoperating (unpacked)

10 Hz to 250 Hz, 1.54 GRMS random vibration, 15 minutes, 3 axes

Transit and storage (packed)

2 Hz to 200 Hz, 0.8 GRMS random vibration, 30 minutes, 6 axes

Shock

Operating (no damage)

31-G +/-5%, with pulse duration of 2.6 ms or less half-sine, bottom side tested only

Nonoperating

71-G +/-5%, with pulse duration of 2.0 ms or less half-sine, all six sides tested

Transit (packed)

Height 24.015 in. (610 mm), six sides, two corners, six edges


TABLE 3-7 J4400 Shock and Vibration

Condition

Parameter

Specification

Vibration

Operating

0.25 G (peak), 3 to 200 Hz sweep @ 1/2 octave per minute, bottom side tested only

Nonoperating (unpacked)

10 Hz to 250 Hz, 1.54 GRMS random vibration, 15 minutes, 3 axes

Transit and storage (packed)

2 Hz to 200 Hz, 0.8 GRMS random vibration, 30 minutes, 6 axes

Shock

Operating (no damage)

31-G +/-5%, with pulse duration of 2.6 ms or less half-sine, bottom side tested only

Nonoperating

71-G +/-5%, with pulse duration of 2.0 ms or less half-sine, all six sides tested

Transit (packed)

Height 17.992 in. (457 mm), six sides, two corners, six edges


Table shows the non-operating temperature, relative humidity, altitude, shock, vibration, and heat output ranges of the array trays.


Electrical Requirements

This section provides information regarding site power and wiring, module AC power requirements, and power cord routing instructions.

Site Wiring and Power

The tray uses wide-ranging redundant power supplies that automatically accommodate voltages to the AC power source. The power supplies operate within the range of 100 VAC to 240 VAC, at a minimum frequency of 47 Hz and a maximum frequency of 63 Hz. The power supplies meet standard voltage requirements for both domestic (inside USA) and international (outside USA) operation. They use standard industrial wiring with line-to-neutral or line-to-line power connections.

Power Input

The AC power sources must provide the correct voltage, current, and frequency specified on the tray model and serial number label. The tray can run without interruption within the limits shown in TABLE 3-8 and TABLE 3-9.


TABLE 3-8 J4200 Tray AC Power Requirements

Condition

Specification

AC power

9 A maximum operating (100 VAC to 127 VAC range), 47 to 63 Hz

4.5 A maximum operating (200 VAC to 240 VAC range), 47 to 63 Hz

Maximum operating current

1.51 A maximum operating @ 240 VAC (198 VAC to 264 VAC range), 50 to 60 Hz


.


TABLE 3-9 J4400 Tray AC Power Requirements

Condition

Specification

AC power

10 A maximum operating @ (100 VAC to 127 VAC range), 47 to 63 Hz

Maximum operating current

27.4 A maximum operating @ 240 VAC (198 VAC to 264 VAC range), 50 to 60 Hz


Table shows the voltage,current, and fr4equency of the tray..

Power Cords and Receptacles

All trays are shipped with two AC power cords that are appropriate for use in a typical outlet in the destination country.

Each power cord connects one of the power supplies in a tray to an independent external power source, such as those provided in the supported Sun cabinet, a wall receptacle, or uninterruptible power supply (UPS).