Hardware Open Issues
|
For Server Modules Running Linux, Load pciehp.ko and Unload acpiphp.ko Before Hot Plugging NEMs or PCIe EMs (7078324)
|
Open
|
No
|
Power Consumption Is Invalid in ILOM if PSU Side Is Under 25A (6438921)
|
Open
|
Yes
|
NEM LEDs (6713414)
|
Open
|
No
|
ILOM Open Issues
|
CMM Resets When Server Module Firmware Is Updated From the CLI (7148752)
|
Open
|
Yes
|
Reset Server Modules Running Oracle ILOM 2.0.3.10 After Updating the CMM to Oracle ILOM 3.0.3.32 (6812532)
|
Open
|
Yes
|
The stop /CH Command in Oracle ILOM 2.0.3.2 is Different Than in Oracle ILOM 2.0.3.1 (6679679)
|
Open
|
No
|
FRU ID Data Correction for Oracle ILOM 2.0.3.1 (6631275)
|
Open
|
Yes
|
Remote Console for Sun Blade X4-2B Server Module SW1.2 Fails When Launched From CMM Web Interface (18962552)
|
Open
|
Yes
|
Resetting the NEM from CMM (7054401)
|
Open
|
Yes
|
IPMItool Might Not Read FRU ID of Power Supply (7029143)
|
Open
|
No
|
CMM Cannot Read Sun Blade X6220 Sensor Readings (6957263)
|
Open
|
Yes
|
Oracle ILOM Service Processor (SP) Lockup (6471005)
|
Open
|
No
|
/CH/BLn/SP/cli/User Command Accepts Invalid Values (6497752)
|
Open
|
Yes
|
Startcli Does Not Authenticate LDAP and Radius Users (6526825)
|
Open
|
Yes
|
CMM Does Not Change or Detect Blade’s SP (6531753, 6529037)
|
Open
|
Yes
|
Fixed in ILOM 3.0.16 (Sun Blade Chassis SW 4.1)
|
|
|
Locate LED on AST2100 CMM Might Not Illuminate (6966212)
|
Fixed
|
Yes
|
Sun Blade 6000 Modular System and Sun Blade Storage Module M2 Mixed Configuration Fails With Chassis Power Cycle (6979665)
|
Fixed
|
Yes
|
Incomplete Fault Information for Specific Faults (6939917)
|
Fixed
|
Yes
|
A90-D Chassis Fans Marked Faulty When All Blades Are Off (6956228/2198329)
|
Fixed
|
No
|
TFTP Update of Sun Blade 6000 Ethernet Switched NEM 24p 10GE Firmware From CMM Failed (6977651)
|
Fixed
|
Yes
|
PSU V_3V3 impitool Output Is Incorrect When PSU Is Removed (6981111)
|
Fixed
|
No
|
Load Source CLI Help Text Says Command Failed (6975735)
|
Fixed
|
No
|
Fixed in ILOM 3.0.12 (Sun Blade Chassis SW 3.3)
|
|
|
Moving the CMM to a Different Chassis Can Cause Incorrect Product Data (6821052)
|
Fixed
|
Yes
|
Fixed in ILOM 3.0.10 (Sun Blade Chassis SW 3.2)
|
Blade Fan Control Improvement (6903302)
|
Fixed
|
No
|
Sun Blade 6000 Virtualized Multi-Fabric 10GbE NEM Powers on When Inserted in Chassis with Oracle ILOM 3.0.6.11 (6894641)
|
Fixed
|
No
|
CMM permitted_power Error Message is Unclear (6863970)
|
Fixed
|
No
|
Resetting Sun Blade 6000 Virtualized Multi-Fabric 10GbE NEM SP from CMM Fails (6865520)
|
Fixed
|
No
|
start /CH or start /CH/NEMx Does Not Warn That Target Is Already Started (6867739)
|
Fixed
|
No
|
Cold Boot of CMM Causes Abnormal Chassis Fan Speed (6876374)
|
Fixed
|
Yes
|
Sun Blade 6000 Virtualized Multi-Fabric 10GbE NEM SP OK-to-Remove LED Is Not Displayed Correctly in the CMM (6878066)
|
Fixed
|
No
|
NEM OK LED Should Have Blinking State (6864854)
|
Fixed
|
No
|
Fixed in ILOM 3.0.6.11c (Sun Blade 6000 Chassis SW 3.1.3)
|
|
|
CMM Power/OK LED No Longer Works With Oracle ILOM 3.0.3.32 (6869525)
|
Fixed
|
No
|
Low Fan Speed With Certain Blade Servers (6911651)
|
Fixed
|
No
|
Fixed in ILOM 3.0.6.11b (Sun Blade 6000 Chassis SW 3.1.2)
|
|
|
fru_name for Sun Blade 6000 Ethernet Switched NEM 24P 10GE NEM is not displayed in CMM (6887409)
|
Fixed
|
No
|
The Locate LED of Sun Blade 6000 Ethernet Switched NEM 24P 10GE NEM Does Not Blink Fast When fast_blink Value is Set (6887470)
|
Fixed
|
No
|
Fixed in ILOM 3.0.6.11 (Sun Blade 6000 Chassis SW 3.1)
|
|
|
Chassis Amber LED Turns on When PSU0 Is Plugged Into the Chassis (6866727)
|
Fixed
|
No
|
Reset Fails for Sun Blade 6000 Virtualized Multi-Fabric 10 GbE NEM (6866739)
|
Fixed
|
No
|
CMM Web Interface Slow Response (6853788)
|
Fixed
|
No
|
PSU Fan Speed Should Run Slower (6853866)
|
Fixed
|
No
|
Need to Include Assembly Number for the CMM (6866148)
|
Fixed
|
No
|
Fixed in ILOM 3.0.3.32 (Sun Blade 6000 Chassis SW 3.0)
|
|
|
CMM OK LED Turns Off During Boot (6474460)
|
Fixed
|
No
|
Oracle ILOM CMM SP Does Not Display Current Status Information (6516108)
|
Fixed
|
No
|
/CH/LOCATE Does Not Turn Off When Set to ON Using the Oracle ILOM CLI or ipmitool (6695802)
|
Fixed
|
No
|
Locate LED Does not Turn on During Chassis Lamp Test (6713569, 6711416)
|
Fixed
|
No
|
SP Reports Incorrect FM, NEM, and Server Module Removal and Insertion Events (6744044)
|
Fixed
|
No
|
SP Login Through Web Interface Fails After a New IP Address Is Assigned (6745118)
|
Fixed
|
Yes
|
Cannot Set Netmask When Running Oracle ILOM 2.0.3.10 (6766379)
|
Fixed
|
Yes
|
Stop, Start and Reset Commands are Disabled for the Virtualized NEM in the Sun Blade 6000 CMM (6813859 and 6812683)
|
Fixed
|
No
|
Fixed in ILOM 2.0.3.10 (Sun Blade 6000 Chassis SW 2.1)
|
|
|
Power LED Does Not Display Until SP Boots (6464862)
|
Fixed
|
Yes
|
Fixed in ILOM 2.0.3.3 (Sun Blade 6000 Chassis SW 2.0)
|
|
|
SNMP Trap Destination Port Should Be Configurable (6654887)
|
Fixed
|
No
|
The stop /CH Command Lights the Chassis Alert LED (6678328)
|
Fixed
|
No
|
LED Test Mode Causes An SEL Message (6713569)
|
Fixed
|
No
|
Fixed in ILOM 2.0.3.2 (Sun Blade 6000 Chassis SW 1.2)
|
|
|
Oracle ILOM Reports Different Status Value When PSU is Removed (6530748)
|
Fixed
|
Yes
|
DC Output Power Supply Issue Fixed in Oracle ILOM 2.0.3.2 (6664200)
|
Fixed
|
No
|
Fixed in ILOM 2.0.3.1 (Sun Blade 6000 Chassis SW 1.1a)
|
|
|
Fan Thresholds Not Read by the CMM and Blades (6513836)
|
Fixed
|
No
|
Removing a Fan Logs Assert and Deassert Events in CMM SEL (6514930)
|
Fixed
|
No
|
CMM NET MGT 1 Port Disabled (6521145)
|
Fixed
|
No
|
Chassis Reports as Powered on When Powered Off (6531040)
|
Fixed
|
Yes
|
SP Allows One CLI Session (6540550)
|
Fixed
|
Yes
|
Fixed in ILOM 1.1.6 (Sun Blade 6000 Chassis SW 1.0)
|
|
|
Two Connected CMM Gigabit Ethernet Ports Causes Slow Network (6498417)
|
Fixed
|
No
|
PSU I_12V Sensor Reads 2.5 Amps Instead of 0 When Power Cord is Unplugged (6516034)
|
Fixed
|
Yes
|
BMC Stops Responding and the CPLD Version Displays as 0.0 (6517737)
|
Fixed
|
Yes
|
Documentation Open Issues
|
|
|
FMods Are Not Supported on the Sun Blade Storage Module M2
|
Open
|
No
|
IPV6 Network Settings Only Available for the A90-D Chassis
|
Open
|
No
|
Incorrect Directory for DHCP IP address in Getting Started Guide (6589651)
|
Open
|
No
|
Incorrect Document Reference in Integrated Lights Out Manager (ILOM) Administration Guide (6595111)
|
Open
|
No
|
URL Clarification for Integrated Lights Out Manager (ILOM) Administration Guide (6596617)
|
Open
|
No
|
Incorrect Note in Integrated Lights Out Manager (ILOM) Administration Guide (6628649)
|
Open
|
No
|
Service Processor Information Missing From Installation Guide (6692159)
|
Open
|
No
|
References to Integrated Lights Out Manager (ILOM) Documentation
|
Open
|
No
|
Power Supply Module Rating Incorrect in Some Documentation
|
Open
|
No
|
Supported Racks List Is Incorrect in Installation Guide
|
Open
|
No
|