Table A-1 lists the physical specifications.
Table A-1
Physical Specifications
Height: 116.00 mm (4.57 inches)
Width: 244.00 mm (9.61 inches)
Depth: 264.00 mm (10.39 inches)
Weight: 12 lbs (5.45 kg)
Table A-2 lists the input power requirements for the DSM. The power supply
automatically selects the correct AC voltage range.
Table A-2
Input Power Requirements for DSM
Operating Maximum Maximum Maximum Thermal Operating
Voltage Input Input Input Dissipation Frequency
Range Current Power Volt-Amps Range
AC 100 -120 1.3 Amps 90 Watts 130 30 Watts 47-63 Hz
AC 200-240 0.65 Amps 90 Watts 130 30 Watts 47-63 Hz
Table A-3 lists the environmental requirements for the operating environment
and the non-operating environment.
Table A-3
Table of Environmental Requirements
Operating Environment:
Temperature between 10 to 45 degrees C (50 and 113
degrees F)
Humidity 20 to 80% relative noncondensing at 40 degrees
C (104 degrees F)
Wet Bulb 26 degrees C (79 degrees F) maximum
Altitude -305 to 2,000 m (-1000 to 6,560 ft)
Non-Operating Environment:
Temperature between 10 to 45 degrees C (50 to 113
degrees F)
Humidity 20 to 80% relative noncondensing at
40 degrees C (104 degrees F)
Wet Bulb 26 degrees C (79 degrees F) maximum
Altitude -305 to 3000 m (-1000 to 10,000 ft)
Storage Environment:
Temperature between -10 to 50 degrees C (14 to 122
degrees F)
Humidity 5 to 95% relative noncondensing at
40 degrees C (104 degrees F)
Altitude -305 to 3000 m (-1000 to 10,000 ft)