Netra 150 Server Hardware Installation Manual

Appendix A System Specifications

Physical Specifications

Table A-1 Netra 150 System Physical Specifications

 

U.S . 

Metric 

Height 

22.44 in 

57.45 cm 

Width 

10.31 in 

26.39 cm 

Depth 

26.77 in 

68.53 cm 

Weight 

55 - 143 lb 

25 - 65 kg 

Table A-2 Clearance and Service Access

 

U.S. 

Metric 

Front 

11.5 in 

29 cm 

Rear 

6.6 in 

17 cm 

Left  

4 in 

10 cm 

Right 

4 in 

10 cm 

Electrical Specifications

The electrical specifications are listed separately for each type of power supply.

Table A-3 Netra 150 System Electrical Specifications, 120V UPS

Parameter 

 

Value 

Input current 

Voltage range 

100~120Vac 

 

Current, maximum 

6.3A 

 

Current frequency range 

50~60Hz 

Output current 

+3.3 VDC, maximum 

12A 

 

+5 VDC, maximum 

33A 

 

+12 VDC, maximum 

17.1A 

 

-12 VDC, maximum 

0.3A 

 

+3.0P VDC, maximum 

12A 

Input power rating 

Total continuous power 

600W maximum 

Volt-Ampere rating 

 

630VA maximum 

BTU rating 

 

2050 BTU/hr. 

Power factor 

 

0.95 at full load 

Plug type 

U.S. 

IEC320 

Table A-4 Netra 150 System Electrical Specifications, 240V UPS

Parameter 

 

Value 

Input current 

Voltage range 

200~240Vac 

 

Current, maximum 

3.0A 

 

Current frequency range 

50~60Hz 

Output current 

+3.3 VDC, maximum 

12A 

 

+5 VDC, maximum 

33A 

 

+12 VDC, maximum 

17.1A 

 

-12 VDC, maximum 

0.3A 

 

+3.0P VDC, maximum 

12A 

Input power rating 

Total continuous power 

570W maximum 

Volt-Ampere rating 

 

600VA maximum 

BTU rating 

 

1950 BTU/hr. 

Power factor 

 

0.95 at full load 

Plug type 

International 

IEC320 

Environmental Requirements

Table A-5 Temperature Limits

 

Metric 

U.S. 

Operating Temperature 

10 - 35C

50 - 95F

Non-Operating Temperature 

-20 - 50C

-4 - 122F

Table A-6 Humidity Limits

 

Metric 

U.S. 

Operating Humidity 

20 - 80% 

20 - 80% 

 

noncondensing 27C 

noncondensing 81F 

 

maximum wet bulb 

maximum wet bulb 

Non-Operating Humidity 

93%, noncondensing 

93%, noncondensing 

Table A-7 Altitude Limits

 

Metric 

U.S. 

Operating Altitude 

3 Km 

10,000 Ft 

Non-Operating Altitude 

12 Km 

40,000 Ft