Netra 150 Server Hardware Installation Manual

Electrical Specifications

The electrical specifications are listed separately for each type of power supply.

Table A-3 Netra 150 System Electrical Specifications, 120V UPS

Parameter 

 

Value 

Input current 

Voltage range 

100~120Vac 

 

Current, maximum 

6.3A 

 

Current frequency range 

50~60Hz 

Output current 

+3.3 VDC, maximum 

12A 

 

+5 VDC, maximum 

33A 

 

+12 VDC, maximum 

17.1A 

 

-12 VDC, maximum 

0.3A 

 

+3.0P VDC, maximum 

12A 

Input power rating 

Total continuous power 

600W maximum 

Volt-Ampere rating 

 

630VA maximum 

BTU rating 

 

2050 BTU/hr. 

Power factor 

 

0.95 at full load 

Plug type 

U.S. 

IEC320 

Table A-4 Netra 150 System Electrical Specifications, 240V UPS

Parameter 

 

Value 

Input current 

Voltage range 

200~240Vac 

 

Current, maximum 

3.0A 

 

Current frequency range 

50~60Hz 

Output current 

+3.3 VDC, maximum 

12A 

 

+5 VDC, maximum 

33A 

 

+12 VDC, maximum 

17.1A 

 

-12 VDC, maximum 

0.3A 

 

+3.0P VDC, maximum 

12A 

Input power rating 

Total continuous power 

570W maximum 

Volt-Ampere rating 

 

600VA maximum 

BTU rating 

 

1950 BTU/hr. 

Power factor 

 

0.95 at full load 

Plug type 

International 

IEC320