This document contains installation and operational information for the Sun(TM) StorEdge(TM) A1000 disk array and A3x00 storage systems. It is divided into the following sections:
Read the information in this supplement before installing or operating the disk array.
Check this document periodically for updates to the issues listed. This document was last updated July 10, 1998.
There are currently two active bugs against the Sun StorEdge A3000 disk array (see Table 1-1).
Table 1-1 Active BugsBud ID | Description |
---|---|
4151778 | RM6.1.1 /Tools/add16lun.sh breaks device ID's 8-15 |
4117560 | Downloading Firmware causes drives to fail. |
For the synopsis, symptom, and workaround for each of these bugs, go to the following website:
http://sunsolve2.sun.com/fcs/A1000_A3000/index.html
This section contains the initial cold start surge current specifications for the StorEdge A3000 and A3500 Systems.
Table 1-2 Device Surge Current SpecificationsDevice | Specification1 |
---|---|
StorEdge A3000 Controller Module | 25A rms or 35A peak for one line cycle |
RSM Disk Array | 15A rms or 21A peak for one line cycle |
StorEdge D1000 Disk Array | 11A rms or 22A peak for one line cycle |
1. For each power supply |
Table 1-3 Cabinet Surge Current Specifications
Device | Specification1 |
---|---|
StorEdge A3000 (StorEdge A3000 controller module with RSM Disk Arrays in 56-inch cabinet) | |
1x5 configuration | 25A rms or 35A peak for one line cycle |
StorEdge A3500 (StorEdge A3000 controller with StorEdge D1000 Disk Arrays in 72-inch cabinet) | |
1x5 configuration | 44A rms or 88A peak for one line cycle |
2x7 configuration | 72A rms or 114A peak for one line cycle |
1x8 configuration | 55A rms or 110A peak for one line cycle |
1. For each power cord |