Sun StorEdge A1000 and A3x00 Installation Supplement

StorEdge A3x00 Surge Specifications

This section contains the initial cold start surge current specifications for the StorEdge A3000 and A3500 Systems.

Table 1-2 Device Surge Current Specifications
 DeviceSpecification1
 StorEdge A3000 Controller Module 25A rms or 35A peak for one line cycle
 RSM Disk Array 15A rms or 21A peak for one line cycle
 StorEdge D1000 Disk Array 11A rms or 22A peak for one line cycle
 1. For each power supply

Table 1-3 Cabinet Surge Current Specifications
 DeviceSpecification1
 StorEdge A3000 (StorEdge A3000 controller module with RSM Disk Arrays in 56-inch cabinet)
 1x5 configuration 25A rms or 35A peak for one line cycle
 StorEdge A3500 (StorEdge A3000 controller with StorEdge D1000 Disk Arrays in 72-inch cabinet)
 1x5 configuration 44A rms or 88A peak for one line cycle
 2x7 configuration 72A rms or 114A peak for one line cycle
 1x8 configuration 55A rms or 110A peak for one line cycle
 1. For each power cord