This section contains the initial cold start surge current specifications for the StorEdge A3000 and A3500 Systems.
Table 1-2 Device Surge Current SpecificationsDevice | Specification1 |
---|---|
StorEdge A3000 Controller Module | 25A rms or 35A peak for one line cycle |
RSM Disk Array | 15A rms or 21A peak for one line cycle |
StorEdge D1000 Disk Array | 11A rms or 22A peak for one line cycle |
1. For each power supply |
Table 1-3 Cabinet Surge Current Specifications
Device | Specification1 |
---|---|
StorEdge A3000 (StorEdge A3000 controller module with RSM Disk Arrays in 56-inch cabinet) | |
1x5 configuration | 25A rms or 35A peak for one line cycle |
StorEdge A3500 (StorEdge A3000 controller with StorEdge D1000 Disk Arrays in 72-inch cabinet) | |
1x5 configuration | 44A rms or 88A peak for one line cycle |
2x7 configuration | 72A rms or 114A peak for one line cycle |
1x8 configuration | 55A rms or 110A peak for one line cycle |
1. For each power cord |