Sun Open Telecommunications Platform 2.0 Installation Guide

Sun OTP Qualified Hardware

The following table lists the hardware qualified by Sun OTP.

Table B–3 Sun OTP Qualified Hardware

Hardware 

Storage 

NIC 

Sun Fire V210 

Sun StorEdge 3120 SCSI (JBOD) 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3310 SCSI (JBOD) 

Sun StorEdge 3320 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 3511 FC Array (RAID-SATA) 

On-board GE 

X4445A QGE 

X4150A-2 GE Cu 

X4422A-2 Combo 

Sun Fire V240 

Sun StorEdge 3120 SCSI (JBOD) 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3310 SCSI (JBOD) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3320 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 3511 FC Array (RAID-SATA) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X4445A QGE 

X4150A-2 GE Cu 

X4422A-2 Combo 

Netra 240 

Sun StorEdge 3120 SCSI (JBOD) 

Sun StorEdge 3310 SCSI (JBOD) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3320 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 3511 FC Array (RAID-SATA) 

On-board GE 

X4445A QGE 

X4150A-2 GE Cu 

X4422A-2 Combo 

Sun Fire V215 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorageTek 6140 

On-board GE 

X4150A-2 GE Cu 

X4445A QGE 

X4422A-2 Combo 

X7280A-2 GE Cu 

Sun Fire V245 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X4150A-2 GE Cu 

X4445A QGE 

X4422A-2 Combo 

X7280A-2 GE Cu 

Sun Fire X2100 M2 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3310 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 3511 FC Array (RAID-SATA) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X7280A-2 GE Cu 

Sun Fire X2200 M2 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3310 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 3511 FC Array (RAID-SATA) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X7280A-2 GE Cu 

Sun Fire V440 

Sun StorEdge 3120 SCSI (JBOD) 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3310 SCSI (JBOD) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3320 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X4445A QGE 

X4150A-2 GE Cu 

X4422A-2 Combo 

Netra 440 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3310 SCSI (JBOD) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3320 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

On-board GE 

X4445A QGE 

X4150A-2 GE Cu 

X4422A-2 Combo 

Sun Fire V490 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorageTek 6140 

On-board GE 

X4445A QGE 

X4150A-2 GE Cu 

X4422A-2 Combo 

Sun Fire T2000 

Sun StorEdge 3120 SCSI (JBOD) 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X4150A-2 GE Cu 

Netra T2000 

Sun StorEdge 3511 FC Array (RAID-SATA) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X4150A-2 GE Cu 

Sun Fire V445 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorageTek 6140 

On-board GE 

X4150A-2 GE Cu 

X4445A QGE 

X4422A-2 Combo 

X7280A-2 GE Cu 

Sun Fire X4100 M2 

Sun StorEdge 3120 SCSI (JBOD) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorageTek 6140 

On-board GE 

X7280A-2 GE Cu 

Sun Fire X4200 M2 

Sun StorEdge 3120 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X7280A-2 GE Cu 

Netra X4200 M2 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 3511 FC Array (RAID-SATA) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X7280A-2 GE Cu 

Sun Fire V890 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorageTek 6140 

On-board GE 

X4445A QGE 

X4150A-2 GE Cu 

X4422A-2 Combo 

The following table lists the storage device firmware requirements.

Table B–4 Sun OTP System Storage Device Firmware Requirements

Type 

Patch 

Requirement 

StorEdgeTM 3510 FC

RAID 113723-15, JBOD 113662-01 

Version 2.4 of the sccli CLI utility must be installed first.

StorEdge 3511 FC 

113724-09 

Version 2.4 of the sccli CLI utility must be installed first.

StorEdge 3120 SCSI 

113728-02 array controller firmware 

Version 2.4 of the sccli CLI utility must be installed first.

StorEdge 3310 SCSI 

113722-15 

Version 2.4 of the sccli CLI utility must be installed first.

StorEdge 3320 SCSI 

113730-01 

Version 2.4 of the sccli CLI utility must be installed first.

StorEdge 6130 FC 

118185-15 6130 services release, 117856-19 6130 baseline firmware release 

StorEdge 6130 array firmware upgrader patch 118185-15 must be installed first. 

StorageTek 6140 FC 

120337 5.1.0.11 baseline firmware release 

Available through the Common Array Manager (CAM) software package.