JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Blade X6275 M2 Server Module Product Documentation
search filter icon
search icon

Document Information

Using This Documentation

Product Information Web Site

Related Books

About This Documentation (PDF and HTML)

Documentation Comments

Contributors

Change History

Hardware Installation and Product Notes

Hardware Installation

Overview of the Sun Blade X6275 M2 Server Module

Installing and Powering On the Server Module

Setting Up ILOM

Installing a Supported OS

Product Notes

Overview of the Sun Blade X6275 M2 Server Module Product Notes

System Software Release Features

Hardware, Firmware, and BIOS Issues

Management and ILOM Issues

Linux Issues

Oracle Solaris Issues

Windows Issues

Documentation Issues

Operating System Installation

Oracle Solaris Installation

Installing the Oracle Solaris Operating System

Linux Installation

Preparing to Install an OS

Installing Oracle Linux

Installing Red Hat Enterprise Linux

Installing the SLES Operating System

Oracle VM Installation

Introduction to Oracle VM Installation

Installing Oracle VM

Creating a PXE Installation Image for Oracle VM

Windows Installation

Introduction to Windows Installation

Getting Started With Windows Server 2008 Installation

Downloading Server Software

Installing the Windows Server 2008 R2 Operating System

Updating Critical Drivers and Installing Supplemental Software

Incorporating Device Drivers into a WIM Image for WDS

Administration, Diagnostics, and Service

ILOM Supplement

Overview of the ILOM Supplement

Introduction to Oracle ILOM

Managing Power Usage and Monitoring Power Consumption

Configuring the Server Power Restore Policy

Switching the Default Serial Port Output Between SP and Host Console

Updating Firmware

Using the ILOM Preboot Menu

Indicators, Sensors, and Traps

Diagnostics Guide

Preface

Diagnostics Guide

Introduction to Diagnostic Tools

U-Boot Diagnostic Startup Tests

Pc-Check Diagnostics Utility

Accessing the Pc-Check Diagnostics Utility on the Tools and Drivers CD/DVD

Service Manual

Service Manual Overview

Server Module and Components Overview

Product Description

Product Features

About the Sun Blade 6000 Modular System Chassis

Illustrated Parts Breakdown

Front Panel LEDs and Features

Power and Reset

Power Modes

Power Button and Power OK LED

Powering On and Off the Server Module

How to Power the Server Module to Standby Power Mode

How to Power On the Server Module to Full Power Mode

How to Power Off the Server Module

Preparation Procedures for Service and Operation

Preparing the Server for Service

How to Prepare the Server Module for Service

CRUs and FRUs

Required Tools

Safety Information

Performing ESD and Antistatic Prevention Measures

Using the Locate LED to Find the Server Module (Optional)

How to Remove the Server Module from the Chassis

How to Remove the Server Module Top Cover

Preparing the Server for Operation

How to Prepare the Server Module for Operation

How to Install the Server Module Top Cover

How to Install the Server Module in the Chassis

Component Removal and Installation Procedures

Replacing the System Battery

Battery Replacement Illustration

How to Replace the System Battery

Removing and Installing DIMMs

How to Identify Faulty DIMMs

DIMM Slot Designations and Population Order

DIMM Population Rules and Guidelines for the Sun Blade X6275 M2 Server module

How to Remove DIMMs

How to Install DIMMs

Removing and Installing Flash Modules

How to Remove Flash Modules

How to Install Flash Modules

Removing and Installing the Energy Storage Modules

How to Remove the Energy Storage Modules

How to Install the Energy Storage Modules

Removing and Installing the Service Processor Board

How to Remove the Service Processor Board

How to Install the Service Processor Board

Removing and Installing USB Flash Drives

How to Remove USB Flash Drives

How to Install USB Flash Drives

Removing and Installing a CPU and Heatsink Assembly

How to Identify a Faulty CPU

How to Remove a CPU and Heatsink Assembly

How to Install a CPU and Heatsink Assembly

How to Replace the Motherboard Assembly

Diagnostic and Maintenance Information and Procedures

Diagnosing Server Module Hardware Faults

LED Functions

Using the DIMM and CPU On-Board Test Circuitry

Using the Multi-Port Cable

Clearing CMOS NVRAM and Resetting Passwords

Recovering from Corrupted Service Processor Firmware

BIOS Power-On Self-Test (POST) Codes

About POST

How BIOS POST Memory Testing Works

Viewing POST Codes Using ILOM

How to Change the POST Options

POST Codes

Server Module Maintenance Procedures and Information

About the BIOS Setup Utility

How to Display FRUID Information

How to Back Up FRU Information

Removing and Installing a Server Module Filler Panel

Specifications

Dimensions

Environmental Specifications

USB Flash Drive Specifications

Index

POST Codes

The table below contains descriptions of each of the POST codes, listed in the same order in which they are generated. These POST codes appear at the bottom right of the BIOS screen as a four-digit string that is a combination of two-digit output from primary I/O port 80 and two-digit output from secondary I/O port 81. In the POST codes listed below, the first two digits are from port 81 and the last two digits are from port 80.

You can see some of the POST codes from primary I/O port 80 on LEDs inside the front panel of your server node (see POST Code LEDs).

The Response column describes the action taken by the system on encountering the corresponding error. The actions are:

Table 5 Error Messages and Responses

Error Code
Error Message
Response
0000
Timer Error
Pause
0003
CMOS Battery Low
Pause
0004
CMOS Settings Wrong
Pause
0005
CMOS Checksum Bad
Pause
000B
CMOS Memory Size Wrong
Pause
000C
RAM R/W Test Failed
Pause
000E
A: Drive Error
Pause
000F
B: Drive Error
Pause
0012
CMOS Date/Time Not Set
Pause
0040
Refresh Timer Test Failed
Halt
0041
Display Memory Test Failed
Pause
0042
CMOS Display Type Wrong
Pause
0043
~<INS> Pressed
Pause
0044
DMA Controller Error
Halt
0045
DMA-1 Error
Halt
0046
DMA-2 Error
Halt
0047
Unknown BIOS error. Error code = 0047
Halt
0048
Password Check Failed
Halt
0049
Unknown BIOS error. Error code = 0049
Halt
004A
Unknown BIOS error. Error code = 004A
Pause
004B
Unknown BIOS error. Error code = 004B
Pause
004C
Keyboard/Interface Error
005D
S.M.A.R.T. Command Failed
005E
Password Check Failed
Pause
0101
Warning! This system board does not support the power requirements of the installed processor. The processor will be run at a reduced frequency, which will impact system performance.
Pause
0102
Error! The CPU Core to Bus ratio or VID configuration has failed! Please enter BIOS Setup and re-config it.
Pause
0103
ERROR! CPU MTRRs configuration failed!

Uncacheable memory hole or PCI space too complicated.

0120
Thermal Trip Failure
Pause
0121
Thermal Trip Failure
Pause
0122
Thermal Trip Failure
Pause
0123
Thermal Trip Failure
Pause
0124
Thermal Trip Failure
Pause
0125
Thermal Trip Failure
Pause
0126
Thermal Trip Failure
Pause
0127
Thermal Trip Failure
Pause
0128
Thermal Trip Failure
0129
Thermal Trip Failure
012A
Thermal Trip Failure
012B
Thermal Trip Failure
012C
Thermal Trip Failure
012D
Thermal Trip Failure
012E
Thermal Trip Failure
012F
Thermal Trip Failure
0150
Processor Failed BIST
Pause
0151
Processor Failed BIST
Pause
0152
Processor Failed BIST
Pause
0153
Processor Failed BIST
Pause
0154
Processor Failed BIST
Pause
0155
Processor Failed BIST
Pause
0156
Processor Failed BIST
Pause
0157
Processor Failed BIST
Pause
0158
Processor Failed BIST
0159
Processor Failed BIST
015A
Processor Failed BIST
015B
Processor Failed BIST
015C
Processor Failed BIST
015D
Processor Failed BIST
015E
Processor Failed BIST
015F
Processor Failed BIST
0160
Processor missing microcode
Pause
0161
Processor missing microcode
Pause
0162
Processor missing microcode
Pause
0163
Processor missing microcode
Pause
0164
Processor missing microcode
Pause
0165
Processor missing microcode
Pause
0166
Processor missing microcode
Pause
0167
Processor missing microcode
Pause
0168
Processor missing microcode
0169
Processor missing microcode
016A
Processor missing microcode
016B
Processor missing microcode
016C
Processor missing microcode
016D
Processor missing microcode
016E
Processor missing microcode
016F
Processor missing microcode
0180
BIOS does not support current stepping
Pause
0181
BIOS does not support current stepping
Pause
0182
BIOS does not support current stepping
Pause
0183
BIOS does not support current stepping
Pause
0184
BIOS does not support current stepping
Pause
0185
BIOS does not support current stepping
Pause
0186
BIOS does not support current stepping
Pause
0187
BIOS does not support current stepping
Pause
0188
BIOS does not support current stepping
0189
BIOS does not support current stepping
018A
BIOS does not support current stepping
018B
BIOS does not support current stepping
018C
BIOS does not support current stepping
018D
BIOS does not support current stepping
018E
BIOS does not support current stepping
018F
BIOS does not support current stepping
0192
L2 cache size mismatch.
0193
CPUID, Processor stepping are different.
0194
CPUID, Processor family are different.
Pause
0195
Front side bus mismatch. System halted.
0196
CPUID, Processor Model are different.
Pause
0197
Processor speeds mismatched.
Pause
5120
CMOS cleared by jumper.
Pause
5121
Password cleared by jumper.
Pause
5125
Not enough conventional memory to copy PCI Option ROM.
5180
Unsupported Memory Vendor : DIMM_A0
Warning
5181
Unsupported Memory Vendor : DIMM_A1
Warning
5182
Unsupported Memory Vendor : DIMM_A2
Warning
5183
Unsupported Memory Vendor : DIMM_A3
Warning
5184
Unsupported Memory Vendor : DIMM_A4
5185
Unsupported Memory Vendor : DIMM_B0
Warning
5186
Unsupported Memory Vendor : DIMM_B1
Warning
5187
Unsupported Memory Vendor : DIMM_B2
Warning
5188
Unsupported Memory Vendor : DIMM_B3
Warning
5189
Unsupported Memory Vendor : DIMM_B4
Warning
518A
Unsupported Memory Vendor : DIMM_B5
Warning
518B
Unsupported Memory Vendor : DIMM_C0
Warning
518C
Unsupported Memory Vendor : DIMM_C1
Warning
518D
Unsupported Memory Vendor : DIMM_C2
Warning
518F
Unsupported Memory Vendor : DIMM_C3
Warning
5190
Unsupported Memory Vendor : DIMM_C4
Warning
5191
Unsupported Memory Vendor : DIMM_C5
Warning
5192
Unsupported Memory Vendor : DIMM_D0
Warning
5193
Unsupported Memory Vendor : DIMM_D1
Warning
5194
Unsupported Memory Vendor : DIMM_D2
Warning
5195
Unsupported Memory Vendor : DIMM_D3
Warning
5196
Unsupported Memory Vendor : DIMM_D4
Warning
5197
Unsupported Memory Vendor : DIMM_D5
Warning
51A0
Unsupported AMB Vendor : DIMM_A0
Warning
51A1
Unsupported AMB Vendor : DIMM_A1
Warning
51A2
Unsupported AMB Vendor : DIMM_A2
Warning
51A3
Unsupported AMB Vendor : DIMM_A3
Warning
51A4
Unsupported AMB Vendor : DIMM_A4
Warning
51A5
Unsupported AMB Vendor : DIMM_A5
Warning
51A6
Unsupported AMB Vendor : DIMM_B0
Warning
51A7
Unsupported AMB Vendor : DIMM_B1
Warning
51A8
Unsupported AMB Vendor : DIMM_B2
Pause
51A9
Unsupported AMB Vendor : DIMM_B3
Warning
51AA
Unsupported AMB Vendor : DIMM_B4
Warning
51AB
Unsupported AMB Vendor : DIMM_B5
Warning
51AC
Unsupported AMB Vendor : DIMM_C0
Warning
51AD
Unsupported AMB Vendor : DIMM_C1
Pause
51AE
Unsupported AMB Vendor : DIMM_C2
Warning
51AF
Unsupported AMB Vendor : DIMM_C3
Pause
51B0
Unsupported AMB Vendor : DIMM_C4
Pause
51B1
Unsupported AMB Vendor : DIMM_C5
Pause
51B2
Unsupported AMB Vendor : DIMM_D0
51B3
Unsupported AMB Vendor : DIMM_D1
51B4
Unsupported AMB Vendor : DIMM_D2
51B5
Unsupported AMB Vendor : DIMM_D3
51B6
Unsupported AMB Vendor : DIMM_D4
51B7
Unsupported AMB Vendor : DIMM_D5
51C0
Memory Configuration Error.
8101
Warning! USB Host Controller not found at the specified address!!!
8102
Error! USB device failed to initialize!!!
8104
Warning! Port 60h/64h emulation is not supported by this USB Host Controller!!!
8105
Warning! EHCI controller disabled. It requires 64bit data support in the BIOS.
8301
Not enough space in runtime area. SMBIOS data will not be available.
8302
Not enough space in runtime area. SMBIOS data will not be available.
8601
Error: BMC Not Responding
8701
Insufficient Runtime space for MPS data.!.

System may operate in PIC or Non-MPS mode.