JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Netra SPARC T4-2 Server HTML Document Collection
search filter icon
search icon

Document Information

Using This Documentation

Product Notes

Related Documentation

Feedback

Support and Accessibility

Installation

Understanding the Server

Installation Task Overview

Server Overview

Front Panel Components

Rear Panel Components

Confirming Server and Site Specifications

Physical Specifications

Electrical Specifications

Input Power Information

Overcurrent Protection Requirements

DC Power Source, Power Connection, and Grounding Requirements

Environmental Requirements

Acoustic Noise Emissions

Airflow Clearance

Preparing for Installation

Shipping Kit

Handling Precautions

ESD Precautions

Tools Needed for Installation

Installing the Server

Optional Components

PCIe2 Expansion Slot Guidelines

Rack Compatibility

Rack Cautions

Stabilize the Rack

Mounting the Server Into a 4-Post Rack

Mounting the Server Into a 2-Post Rack

Connecting Cables

Cabling Requirements

Identifying Ports

Connecting Data and Management Cables

Powering On the Server for the First Time

Assemble the DC Power Cords

Prepare the Power Cords

Connect a Terminal or Emulator to the SER MGT Port

Power On the Server for the First Time

Oracle Solaris OS Configuration Parameters

Assign a Static IP Address to the SP

Administration

Understanding System Administration Resources

Oracle ILOM Overview

Platform-Specific Oracle ILOM Features

Oracle Solaris OS Overview

OpenBoot Overview

Oracle VM Server for SPARC Overview

Multipathing Software

Hardware Management Pack Overview

Source for Downloading Hardware Management Pack Software

Hardware Management Pack Documentation

Accessing the Server

Log In to Oracle ILOM

Log In to the System Console

Display the ok Prompt

Display the Oracle ILOM -> Prompt

Use a Local Graphics Monitor

Oracle ILOM Remote Console

Controlling the Server

Power On the Server (Oracle ILOM)

Power Off the Server (Oracle ILOM)

Reset the Server (Oracle Solaris OS)

Reset the Server (Oracle ILOM)

Reset the SP to Default Values

Configuring Hardware RAID

Hardware RAID Support

Important Hardware RAID Guidelines

Prepare to Use the FCode Utility

FCode Utility Commands

Create a Hardware RAID Volume

Hot Spare Drives in RAID Volumes (LSI)

Determining If a Drive Has Failed

RAID Drive Replacement Strategies

Locate Device Paths

Changing Server Identification Information

Change Customer Data on FRU PROMs

Change System Identifier Information

Configuring Policy Settings

Specify Cooldown Mode

Restore the Host Power State at Restart

Specify the Host Power State at Restart

Disable or Re-Enable the Host Power-On Delay

Specify Parallel Boot of the SP and Host

Configure Host Behavior (Keyswitch State)

Configuring Network Addresses

SP Network Address Options

Disable or Re-Enable Network Access to the SP

Display the DHCP Server IP Address

Display the IP Address of the SP

Display the Host MAC Address

Using an In-band Connection to the SP

Configuring Boot Mode

Boot Mode Overview

Configure the Host Boot Mode (Oracle VM Server for SPARC)

Change the Host Boot Mode Behavior at Reset

Manage the Host Boot Mode Script

Display Host Boot Mode Expiration Date

Override OBP Settings to Reset the Server

Configuring Server Behavior at Restart

Specify Behavior When the Host Resets

Specify Behavior When the Host Stops Running

Set the Boot Timeout Interval

Specify Behavior at Boot Timeout

Specify Behavior if Restart Fails

Specify Maximum Restart Attempts

Configuring Devices

Unconfigure a Device Manually

Reconfigure a Device Manually

Monitoring the Server

Monitoring Faults

Enabling Automatic System Recovery

Display Server Components

Locate the Server

Updating the Firmware

Display the Firmware Version

Update the Firmware

Display OpenBoot Version

Display POST Version

Identifying WWN-Designated SAS2 Devices

World Wide Name Syntax

Mapping WWN Values to Hard Drives (OBP probe-scsi-all Command)

Identify a Disk Slot Using prtconf (Oracle Solaris OS)

WWN Syntax in an OS Installation on an Individual Drive

WWN Syntax in an OS Installation on a RAID Volume

Service

Identifying Components

Power Supply, Hard Drive, and Rear Fan Module Locations

Motherboard, PCIe2 Cards, and SP Locations

Front Fans, Subchassis, Memory Riser, and DIMM Locations

Front Panel Components

Rear Panel Components

Detecting and Managing Faults

Diagnostics Overview

Diagnostics Process

Interpreting Diagnostic LEDs

Managing Faults (Oracle ILOM)

Understanding Fault Management Commands

Interpreting Log Files and System Messages

Checking if Oracle VTS Is Installed

Managing Faults (POST)

Managing Faults (PSH)

Managing Components (ASR)

Preparing for Service

Safety Information

Tools Needed for Service

Filler Panels

Find the Server Serial Number

Locate the Server

Component Service Task Reference

Removing Power From the Server

Accessing Internal Components

Servicing the Air Filter

Remove the Air Filter

Install the Air Filter

Servicing Front Fan Modules

Front Fan Module LEDs

Locate a Faulty Front Fan Module

Remove a Front Fan Module

Install a Front Fan Module

Verify a Front Fan Module

Servicing Hard Drives

Hard Drive LEDs

Locate a Faulty Hard Drive

Remove a Hard Drive

Install a Hard Drive

Verify a Hard Drive

Servicing the DVD Drive

Determine if the DVD Drive Is Faulty

Remove the DVD Drive

Install the DVD Drive

Verify the DVD Drive

Servicing Power Supplies

Power Supply LEDs

Locate a Faulty Power Supply

Remove a Power Supply

Install a Power Supply

Verify a Power Supply

Servicing the Rear Fan Module

Rear Fan Module LEDs

Determine if the Rear Fan Module Is Faulty

Remove the Rear Fan Module

Install the Rear Fan Module

Verify the Rear Fan Module

Servicing Memory Risers

Memory Riser Configuration

Memory Riser LEDs

Locate a Faulty Memory Riser

Remove a Memory Riser

Install a Memory Riser

Verify a Memory Riser

Servicing DIMMs

DIMM Configuration

DIMM IDs

DIMM LEDs

Locate a Faulty DIMM (LEDs)

Locate a Faulty DIMM (Oracle ILOM)

Remove a DIMM

Install a DIMM

Verify a DIMM

Servicing the Battery

Determine if the Battery Is Faulty

Remove the Battery

Install the Battery

Verify the Battery

Servicing PCIe2 Cards

Locate a Faulty PCIe2 Card

Remove a PCIe2 Card

Install a PCIe2 Card

Install SAS Cable for Sun Storage 6 Gb SAS PCIe RAID HBA, Internal

Verify a PCIe2 Card

Servicing the SP

Determine if the SP Is Faulty

Remove the SP

Install the SP

Verify the SP

Servicing the ID PROM

Determine if the ID PROM Is Faulty

Remove the ID PROM

Install the ID PROM

Verify the ID PROM

Servicing the Subchassis

Remove the Subchassis

Install the Subchassis

Servicing the LED Board

Determine if the LED Board Is Faulty

Remove the LED Board

Install the LED Board

Verify the LED Board

Servicing the Motherboard

Determine if the Motherboard Is Faulty

Remove the Motherboard

Install the Motherboard

Verify the Motherboard

Servicing the Power Distribution Board

Determine if the Power Distribution Board Is Faulty

Remove the Power Distribution Board

Install the Power Distribution Board

Verify the Power Distribution Board

Servicing the Hard Drive Backplane

Determine if the Hard Drive Backplane Is Faulty

Remove the Hard Drive Backplane

Install the Hard Drive Backplane

Verify the Hard Drive Backplane

Returning the Server to Operation

Install the Top Cover

Connect Power Cords

Power On the Server (Oracle ILOM)

Power On the Server (Power Button)

Glossary

Index

Update the Firmware

  1. Ensure that the Oracle ILOM SP network management port is configured.

    See the installation guide for your server for instructions.

  2. Open an SSH session to connect to the SP:
    % ssh root@xxx.xxx.xxx.xxx
    ...
    Are you sure you want to continue connecting (yes/no) ? yes
     
    ...
    Password: password (nothing displayed)
    Waiting for daemons to initialize...
     
    Daemons ready
     
    Integrated Lights Out Manager
     
    Version 3.x.x.x
     
    Copyright 2010 Oracle and/or its affiliates. All rights reserved.
    Use is subject to license terms.
     
    -> 
  3. Power off the host:
    -> stop /SYS
  4. Set the keyswitch_state parameter to normal:
    -> set /SYS keyswitch_state=normal
  5. Type the load command with the path to the new flash image.

    The load command updates the SP flash image and the host firmware. The load command requires the following information:

    • IP address of a TFTP server on the network that can access the flash image.

    • Full path name to the flash image that the IP address can access.

      The command usage is as follows:

      load [-script] -source tftp://xxx.xxx.xx.xxx/pathname

      where:

      • -script - Does not prompt for confirmation and acts as if yes was specified.

      • -source - Specifies the IP address and full path name (URL) to the flash image.

    -> load -source tftp://129.99.99.99/pathname
    NOTE: A firmware upgrade will cause the server and ILOM to be reset.
    It is recommended that a clean shutdown of the server be done prior 
    to the upgrade procedure.
    An upgrade takes about 6 minutes to complete. ILOM will enter a 
    special mode to load new firmware.
    No other tasks can be performed in ILOM until the firmware upgrade
    is complete and ILOM is reset.
    Are you sure you want to load the specified file (y/n)?y
    Do you want to preserve the configuration (y/n)? y
    .................................................................
    Firmware update is complete.
    ILOM will now be restarted with the new firmware.
    Update Complete. Reset device to use new image.
    ->

    After the flash image has been updated, the server automatically resets, runs diagnostics, and returns to the login prompt on the serial console.

    U-Boot 1.x.x
     
    Custom AST2100 U-Boot 3.0 (Aug 21 2010 - 10:46:54) r58174
    ***
    Net:   faradaynic#0, faradaynic#1
    Enter Diagnostics Mode ['q'uick/'n'ormal(default)/e'x'tended(manufacturing mode)] .....   0
    Diagnostics Mode - NORMAL
    <DIAGS> Memory Data Bus Test ... PASSED
    <DIAGS> Memory Address Bus Test ... PASSED
    I2C Probe Test - SP
          Bus     Device                          Address Result
          ===     ============================    ======= ======
           6                  SP FRUID (U1101)    0xA0    PASSED
           6               DS1338(RTC) (U1102)    0xD0    PASSED
     
    <DIAGS> PHY #0 R/W Test ... PASSED
    <DIAGS> PHY #0 Link Status ... PASSED
    <DIAGS> ETHERNET PHY #0, Internal Loopback Test ... PASSED
    ## Booting image at 110a2000 ... ***
     
    Mounting local filesystems...
    Mounted all disk partitions.
     
    Configuring network interfaces...FTGMAC100: eth0:ftgmac100_open
    Starting system log daemon: syslogd and klogd.
    Starting capidirect daemon: capidirectd . Done
    Starting Event Manager: eventmgr  . Done
    Starting ipmi log manager daemon: logmgr . Done
    Starting IPMI Stack: . Done
    Starting sshd.
    Starting SP fishwrap cache daemon: fishwrapd . Done
    Starting Host deamon: hostd . Done
    Starting Network Controller Sideband Interface Daemon: ncsid . Done
    Starting Platform Obfuscation Daemon: pod . Done
    Starting lu main daemon: lumain . Done
    Starting Detection/Diagnosis After System Boot: dasboot  Done
    Starting Servicetags discoverer: stdiscoverer.
    Starting Servicetags listener: stlistener.
    Starting Dynamic FRUID Daemon: dynafrud  Done
     
    hostname login:
Related Information