JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Oracle Integrated Lights Out Manager (ILOM) 3.1 Documentation Collection
search filter icon
search icon

Document Information

Using This Documentation

Related Documentation

Documentation Feedback

Product Downloads

Download Product Software and Firmware

Oracle ILOM 3.1 Firmware Version Numbering Scheme

Support and Accessibility

Quick Start

Oracle ILOM 3.1 – Quick Start

Factory Default Settings

Mandatory Setup Tasks

Optional Setup Tasks

Daily Management Tasks

Routine Maintenance Tasks

Initial Setup FAQs

Configuration and Maintenance

Setting Up a Management Connection to Oracle ILOM and Logging In

Establishing a Management Connection to Oracle ILOM

Logging In to Oracle ILOM Server SP or CMM

Configuring Oracle ILOM for Maximum Security

Setting Up and Maintaining User Accounts

Managing User Credentials

Configuring Local User Accounts

Configuring Active Directory

Configuring LDAP/SSL

Configuring LDAP

Configuring RADIUS

Modifying Default Settings for Network Deployment and Administration

Network Deployment Principles and Considerations

Modifying Default Management Access Configuration Properties

Modifying Default Connectivity Configuration Properties

Example Setup of Dynamic DNS

Assigning System Identification Information

Setting Properties for SP or CMM Clock

Suggested Resolutions for Network Connectivity Issues

Using Remote KVMS Consoles for Host Server Redirection

First-Time Setup for Oracle ILOM Remote Console

Launching and Using the Oracle ILOM Remote Console

First Time Setup for Oracle ILOM Storage Redirection CLI

Launching and Using the Oracle ILOM Storage Redirection CLI

Starting and Stopping a Host Serial Redirection Session

Host Serial Console Log Properties

Configuring Host Server Management Actions

Controlling Host Power to Server or Blade System Chassis

Setting Host Diagnostic Tests to Run

Setting Next Boot Device on x86 Host Server

Setting Boot Behavior on SPARC Host Server

Overriding SPARC Host Boot Mode

Managing SPARC Host Domains

Setting SPARC Host KeySwitch State

Setting SPARC Host TPM State

Setting Up Alert Notifications and Syslog Server for Event Logging

Configuring Alert Notifications

Configuring Syslog for Event Logging

Setting System Management Power Source Policies

Power-On and Cooling-Down Policies Configurable From the Server SP

System Management Power Supply Policies Configurable From CMM

Setting Power Alert Notifications and Managing System Power Usage

Setting Power Consumption Alert Notifications

Setting CMM Power Grant and SP Power Limit Properties

Setting SP Advanced Power Capping Policy to Enforce Power Limit

Setting SP Power Management Settings for Power Policy (SPARC)

Setting the CMM Power Supply Redundancy Policy

Performing Oracle ILOM Maintenance and Configuration Management Tasks

Performing Firmware Updates

Reset Power to Service Processor or Chassis Monitoring Module

Backing Up, Restoring, or Resetting the Oracle ILOM Configuration

Maintaining x86 BIOS Configuration Parameters

BIOS Configuration Management

Performing BIOS Configuration Tasks From Oracle ILOM

SAS Zoning Chassis Blade Storage Resources

Zone Management for Chassis-Level SAS-2 Capable Resources

Manageable SAS-2 Zoning-Capable Devices

Sun Blade Zone Manager Properties

Important SAS Zoning Allocations Considerations

Enabling Zoning and Creating SAS-2 Zoning Assignments

Managing Existing SAS-2 Storage Resource Allocations

Resetting Sun Blade Zone Manager Allocations to Factory Defaults

Resetting the Zoning Password to Factory Default for Third-Party In-Band Management

User's Guide

Oracle ILOM Overview

About Oracle ILOM

Oracle ILOM Features and Functionality

Supported Management Interfaces

Supported Operating System Web Browsers

Integration With Other Management Tools

Getting Started With Oracle ILOM 3.1

Logging In to Oracle ILOM

Navigating the Redesigned 3.1 Web Interface

Navigating the Command-Line Interface (CLI) Namespace Targets

Collecting System Information, Monitoring Health Status, and Initiating Host Management

Collecting Information, Status, and Initiating Common Actions

Administering Open Problems

Administering Service Actions: Oracle Blade Chassis NEMs

Managing Oracle ILOM Log Entries

Performing Commonly Used Host Management Actions (Web)

Applying Host and System Management Actions

Administering Host Management Configuration Actions

Administering System Management Configuration Actions

Troubleshooting Oracle ILOM Managed Devices

Network Connection Issues: Oracle ILOM Interfaces

Tools for Observing and Debugging System Behavior

Enabling and Running Oracle ILOM Diagnostic Tools

Real-Time Power Monitoring Through Oracle ILOM Interfaces

Monitoring Power Consumption

Monitoring Power Allocations

Analyzing Power Usage Statistics

Comparing Power History Performance

Managing Oracle Hardware Faults Through the Oracle ILOM Fault Management Shell

Protecting Against Hardware Faults: Oracle ILOM Fault Manager

Oracle ILOM Fault Management Shell

Using fmadm to Administer Active Oracle Hardware Faults

Using fmdump to View Historical Fault Management Logs

Using fmstat to View the Fault Management Statistics Report

Using the Command-Line Interface

About the Command-Line Interface (CLI)

CLI Reference For Supported DMTF Syntax, Command Verbs, Options

CLI Reference For Executing Commands to Change Properties

CLI Reference For Mapping Management Tasks to CLI Targets

CLI Reference

Basic CLI Command Reference for Oracle ILOM 3.1

System Information and Management

Host and System Control

Oracle ILOM Initial Setup

System Monitoring and Status

System Inventory

Oracle ILOM Maintenance

Oracle ILOM Configuration Management

Oracle ILOM Help

SNMP, IPMI, CIM, WS-MAN Protocol Management

SNMP Overview

About Simple Network Management Protocol

SNMP Components

Oracle ILOM SNMP MIBs

SNMP Command-Line Syntax Examples

Configuring SNMP Settings in Oracle ILOM

Managing SNMP Read and Write Access, User Accounts, and SNMP Trap Alerts (CLI)

Managing SNMP Read and Write Access, User Accounts, and SNMP Trap Alerts (Web)

Downloading SNMP MIBs Using Oracle ILOM

Manage User Accounts Using SNMP

Before You Begin – User Accounts (SNMP)

Configuring Oracle ILOM User Accounts (SNMP)

Configuring Oracle ILOM for Active Directory (SNMP)

Manage DNS Name Server Settings (SNMP)

Configuring Oracle ILOM for LDAP (SNMP)

Configuring Oracle ILOM for LDAP/SSL (SNMP)

Configuring Oracle ILOM for RADIUS (SNMP)

Manage Component Information and Email Alerts (SNMP)

Before You Begin – Component Information (SNMP)

Viewing Component Information (SNMP)

Managing Clock Settings, Event Log, Syslog Receiver, and Alert Rules (SNMP)

Configuring SMTP Client for Email Alert Notifications (SNMP)

Configuring Email Alert Settings (SNMP)

Monitor and Manage System Power (SNMP)

Before You Begin – Power Management (SNMP)

Monitoring the Power Consumption Interfaces (SNMP)

Maintaining System Power Policy (SNMP)

Managing System Power Properties (SNMP)

Manage Oracle ILOM Firmware Updates (SNMP)

Update Oracle ILOM Firmware (SNMP)

Manage Oracle ILOM Backup and Restore Configurations (SNMP)

View and Configure Backup and Restore Properties (SNMP)

Manage SPARC Diagnostics, POST, and Boot Mode Operations (SNMP)

Before You Begin – Manage SPARC Hosts (SNMP)

Managing SPARC Diagnostic, POST, and Boot Mode Properties (SNMP)

Server Managment Using IPMI

Intelligent Platform Management Interface (IPMI)

Configuring the IPMI Service

Using IPMItool to Run ILOM CLI Commands

Performing System Management Tasks (IPMItool)

IPMItool Utility and Command Summary

Server Management Using WS-Management and CIM

WS-Management and CIM Overview

Configuring Support for WS-Management in Oracle ILOM

Supported DMTF SMASH Profiles, CIM Classes and CIM Indications

Oracle's Sun-Supported CIM Classes

Document Conventions for Oracle's Sun-Supported CIM Classes

Oracle_AssociatedIndicatorLED

Oracle_AssociatedSensor

Oracle_Chassis

Oracle_ComputerSystem

Oracle_ComputerSystemPackage

Oracle_Container

Oracle_ElementCapabilities

Oracle_ElementConformsToProfile

Oracle_EnabledLogicalElementCapabilities

Oracle_HWCompErrorOkIndication

Oracle_IndicatorLED

Oracle_InstCreation

Oracle_InstDeletion

Oracle_LogEntry

Oracle_LogManagesRecord

Oracle_Memory

Oracle_NumericSensor

Oracle_PhysicalAssetCapabilities

Oracle_PhysicalComponent

Oracle_PhysicalElementCapabilities

Oracle_PhysicalMemory

Oracle_PhysicalPackage

Oracle_Processor

Oracle_ProcessorChip

Oracle_Realizes

Oracle_RegisteredProfile

Oracle_RecordLog

Oracle_ReferencedProfile

Oracle_Sensor

Oracle_SpSystemComponent

Oracle_SystemDevice

Oracle_ThresholdIndication

Oracle_UseOfLog

SNMP Command Examples

snmpget Command

snmpwalk Command

snmpbulkwalk Command

snmptable Command

snmpset Command

snmptrapd Command

Feature Updates and Release Notes

Feature Enhancements as of Oracle ILOM 3.1

Feature Enhancements Summary

Updates to Oracle ILOM 3.1.x Firmware

Initial 3.1 Point Releases for Servers and Sun Blade 6000 CMM

Deprecation Notice for WS-Man as of Oracle ILOM 3.2.1

Oracle ILOM 3.1 Known Issues

Documentation Titles in Translated Documents

Glossary

Index

Oracle_Chassis

Description:
The Oracle_Chassis class represents the physical elements that enclose other elements.
Inheritance:
CIM_Chassis
Properties:
For a description of the supported properties for the Oracle_Chassis class, see the following table.

Note - For more details about Oracle's Sun-supported properties (described in the following table), see the DMTF CIM schema, version 2.18.1, at: http://www.dmtf.org/standards/cim/cim_schema_v2181


http://www.dmtf.org/standards/cim/cim_schema_v2181

Profile:
Physical Asset

Table 114 Properties for Oracle_Chassis

Property
Data Type
Description
Oracle ILOM Value
CreationClassName

string
The CreationClassName property is a mandatory key property

CreationClassName indicates the name of the class or the subclass used in the creation of an instance. When used with the other key properties of this class, this property allows all instances of this class and its subclasses to be uniquely identified.

Set to Oracle_Chassis
Tag

string
The Tag property is a mandatory key property.

The Tag property is an arbitrary string that uniquely identifies the physical element and serves as the key of the element.

The Tag property can contain information such as asset tag or serial number data.

The key for PhysicalElement is placed very high in the object hierarchy to independently identify the hardware or entity, regardless of physical placement in or on cabinets, adapters, and so on.

For example, a hot-swappable or removable component can be taken from its containing (scoping) package and be temporarily unused. The object continues to exist and can be inserted into a different scoping container. Therefore, the key for PhysicalElement is an arbitrary string and is defined independently of any placement or location-oriented hierarchy.

Set to component NAC name
CanBeFRUed
boolean
The CanBeFRUed property is a boolean that indicates whether this PhysicalElement can be FRUed (TRUE) or not (FALSE).
Set to TRUE or FALSE depending on whether the component is considered to be a FRU by the platform.
ChassisPackageType
uint16[]
The ChassisPackageType property indicates the physical form factor for the type of chassis.

This property may have a value when the PackageType property contains the value 3 Chassis Frame. A value of 28 Blade Enclosure indicates the chassis is designed to contain one or more PhysicalPackage(s) of PackageType 16 "Blade" or PackageType 17 "Blade Expansion".

Definition type values include any of the following:

{Unknown, Other, SMBIOS Reserved, Desktop, Low Profile Desktop, Pizza Box, Mini Tower, Tower, Portable, LapTop, Notebook, Hand Held, Docking Station, All in One, Sub Notebook, Space-Saving, Lunch Box, Main System Chassis, Expansion Chassis, SubChassis, Bus Expansion Chassis, Peripheral Chassis, Storage Chassis, SMBIOS Reserved, Sealed-Case PC, SMBIOS Reserved, CompactPCI, AdvancedTCA, Blade Enclosure, DMTF Reserved, Vendor Reserved}

Values for the definition types are:

{0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, .., 0x8000..0xFFFF}

Set to 17 (Main System Chassis).
ChassisTypeDescription
string
The ChassisTypeDescription is a string providing more information about the ChassisPackageType.
Appropriate value.
Description
string
Textual description of the object.
Appropriate value.
ElementName
string
The ElementName property is a user-friendly name.

This property allows each instance to define a user-friendly name in addition to its key properties, identity data, and description information.


Note - The Name property of ManagedSystemElement is also defined as a user-friendly name. But, it is often subclassed to be a key. It is not reasonable that the same property can convey both identity and a user-friendly name, without inconsistencies. Where Name exists and is not a key (such as for instances of LogicalDevice), the same information can be present in both the Name and ElementName properties.


Set to component NAC name.
HealthState
uint16[]
Indicates the current health of the element. This attribute expresses the health of this element but not necessarily that of its subcomponents. The following values apply:
  • 0 (Unknown) - The implementation cannot report on HealthState at this time.

  • 5 (OK) - The element is fully functional and is operating within normal operational parameters and without error.

  • 10 (Degraded/Warning) - The element is in working order, and all functionality is provided. However, the element is not working to the best of its abilities. For example, the element might not be operating at optimal performance, or it might be reporting recoverable errors.

  • 15 (Minor Failure) - All functionality is available, but some might be degraded.

  • 20 (Major Failure) - The element is failing. It is possible that some or all of the functionality of this component is degraded or not working.

  • 25 (Critical Failure) - The element is nonfunctional, and recovery might not be possible.

  • 30 (Non-Recoverable Error) - The element has completely failed, and recovery is not possible. All functionality provided by this element has been lost.

DMTF has reserved the unused portion of the continuum for additional health states in the future.

Has the appropriate value depending on whether the component is in error state or not.
Manufacturer
string
The Manufacturer property is the name of the organization responsible for producing the PhysicalElement.

This organization might be the entity from whom the element is purchased, but this is not necessarily true. The latter information is contained in the vendor property of CIM_Product.

Has the appropriate value if the chassis is considered a FRU by the platform.
Model
string
The Model property is the name by which the PhysicalElement is generally known.
Has the appropriate value if the chassis is considered a FRU by the platform.
OperationalStatus
uint16[]
The OperationalStatus property indicates the current statuses of the element.

Various operational statuses are defined. Many of the enumeration's values are self-explanatory.

Enumeration definitions can include any of the following:

{Unknown, Other, OK, Degraded, Stressed, Predictive Failure, Error, Non-Recoverable Error, Starting, Stopping, Stopped, In Service, No Contact, Lost Communication, Aborted, Dormant, Supporting Entity in Error, Completed, Power Mode, DMTF Reserved, Vendor Reserved}

Values for these definitions are as follows:

{0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, .., 0x8000..}

OperationalStatus[0] will have appropriate value depending on whether the component is in error state or not.
PartNumber
string
Part number assigned by the organization that is responsible for producing or manufacturing the PhysicalElement.
Has the appropriate value if the chassis is considered a FRU by the platform.
SKU
string
The SKU property is the stock-keeping unit number for this PhysicalElement.
Has the appropriate value if the chassis is considered a FRU by the platform.
SerialNumber
string
The SerialNumber property is a manufacturer-allocated number used to identify the PhysicalElement.
Has the appropriate value if the chassis is considered a FRU by the platform.
StatusDescriptions
string
That StatusDescriptions property describes the various OperationalStatus array values.

For example, if Stopping is the value assigned to OperationalStatus, then this property might contain an explanation of why an object is being stopped.

Note that entries in this array are correlated with those at the same array index in OperationalStatus.

StatusDescriptions[0] has the appropriate description on the reason for the value of OperationalStatus[0].