Understanding the Server Module
Front and Rear Panel Components
Confirming Server Module and Site Specifications
Plan Communication With the Server Module During Installation
Prepare the Modular System and Server Module
Insert the Server Module Into the Chassis
Powering On the Server Module for the First Time
Method 1a – Power On the Host Through the CMM (Web Interface)
Method 1b – Power On the Host Through the CMM (CLI)
Method 2 – Power On the Host Through the CMM SER MGT Port (CLI)
Method 3 – Power On the Host Through the Front Panel (SP CLI)
Configuring the Oracle Solaris OS
Install Oracle Solaris Software From the Network
Oracle Solaris Configuration Parameters
Assign a Static IP Address to the SP
Understanding System Administration Resources
Platform-Specific Oracle ILOM Features
Oracle VM Server for SPARC Overview
Hardware Management Pack Overview
Source for Downloading Hardware Management Pack Software
Hardware Management Pack Documentation
Display the Oracle ILOM -> Prompt
Power On the Server (Oracle ILOM)
Power Off the Server (Oracle ILOM)
Reset the Server (Oracle Solaris OS)
Reset the Server (Oracle ILOM)
Reset the SP to Default Values
Important Hardware RAID Guidelines
Prepare to Use the FCode Utility
Hot Spare Drives in RAID Volumes (LSI)
Determining If a Drive Has Failed
RAID Drive Replacement Strategies
Changing Server Identification Information
Change Customer Data on FRU PROMs
Change System Identifier Information
Restore the Host Power State at Restart
Specify the Host Power State at Restart
Disable or Re-Enable the Host Power-On Delay
Specify Parallel Boot of the SP and Host
Configure Host Behavior (Keyswitch State)
Disable or Re-Enable Network Access to the SP
Display the DHCP Server IP Address
Display the IP Address of the SP
Using an In-band Connection to the SP
Configure the Host Boot Mode (Oracle VM Server for SPARC)
Change the Host Boot Mode Behavior at Reset
Manage the Host Boot Mode Script
Display Host Boot Mode Expiration Date
Override OBP Settings to Reset the Server
Configuring Server Behavior at Restart
Specify Behavior When the Host Resets
Specify Behavior When the Host Stops Running
Specify Behavior at Boot Timeout
Specify Behavior if Restart Fails
Specify Maximum Restart Attempts
Enabling Automatic System Recovery
Identifying WWN-Designated SAS2 Devices
Mapping WWN Values to Hard Drives (OBP probe-scsi-all Command)
probe-scsi-all WWN Mapping Overview
probe-scsi-all WWN Mapping Example (SPARC T4-1)
probe-scsi-all WWN Mapping Example (Netra SPARC T4-1)
probe-scsi-all WWN Mapping Example (SPARC T4-2)
probe-scsi-all WWN Mapping Example (Netra SPARC T4-2)
probe-scsi-all WWN Mapping Example (SPARC T4-4 With Four CPUs)
probe-scsi-all WWN Mapping Example (SPARC T4-4 With Two CPUs)
probe-scsi-all WWN Mapping Example (SPARC T4-1B and Netra SPARC T4-1B)
WWN Syntax in an OS Installation on an Individual Drive
WWN Syntax in an OS Installation on a RAID Volume
Front and Rear Panel Components
Interpreting Log Files and System Messages
Checking if Oracle VTS Software Is Installed
Find the Modular System Chassis Serial Number
Find the Server Module Serial Number
Preparing the Server Module for Removal
Remove the Server Module From the Modular System
Clear the Fault and Verify the Functionality of the Replacement DIMM
Replacing the Server Module Enclosure Assembly (Motherboard)
Transfer Components to Another Enclosure Assembly
Returning the Server Module to Operation
Install the Server Module Into the Modular System
Power On the Host (Oracle ILOM)
The procedure described below applies to SPARC T4-1 and SPARC T4-4 servers, which have eight-disk backplane configurations. The same methodology can be used for the SPARC T4-2 server and SPARC T4-1B blade systems.
# format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c0t5000CCA00ABBAEB8d0 <SUN300G cyl 46873 alt 2 hd 20 sec 625> /scsi_vhci/disk@g5000cca00abbaeb8 1. c0t5000C5001D40D7F7d0 <SUN300G cyl 46873 alt 2 hd 20 sec 625> /scsi_vhci/disk@g5000c5001d40d7f7 [...]
The remaining steps in this example will identify the physical slot that corresponds to the device name c0t5000CCA00ABBAEB8d0.
Device Minor Nodes: dev=(32,0) dev_path=/scsi_vhci/disk@g5000cca00abbaeb8:a spectype=blk type=minor dev_link=/dev/dsk/c0t5000CCA00ABBAEB8d0s0 <<=== Device link dev_link=/dev/sd3a dev_path=/scsi_vhci/disk@g5000cca00abbaeb8:a,raw spectype=chr type=minor dev_link=/dev/rdsk/c0t5000CCA00ABBAEB8d0s0 <<=== Device link dev_link=/dev/rsd3a
Note the obp-path value listed under WWN 5000cca00abbaeb8.
Refer to the following table to find the controller.
|
For SPARC T4-1 servers, the controller is identified in the second field: pci@1 = controller 0 and pci@2 = controller 1.
For SPARC T4-4 servers, the controller is identified in the first field. For systems with a four-processor configuration, pci@400 = controller 0 and pci@700 = controller 1. For systems with a two-processor configuration, pci@400 = controller 0 and pci@500 = controller 1.
Note - Because SPARC T4-2 and SPARC T4-1B systems contain only one SAS controller, only controller 0 will be listed.
The following output example shows the obp-path for a SPARC T4-1 server.
Paths from multipath bus adapters: mpt_sas#5 (online) name=’wwn’ type=string items=1 value=’5000cca00abbaeb8’ <<=== Hard drive WWN ID name=’lun’ type=int items=1 value=00000000 name=’target-port’ type=string items=1 value=’5000cca00abbaeb9’ <<=== Hard drive SAS address name=’obp-path’ type=string items=1 value=’/pci@400/pci@1/pci@0/pci@4/scsi@0/disk@w5000cca00abbaeb9,0’ name=’phy-num’ type=int items=1 value=00000000 name=’path-class’ type=string items=1 value=’primary’
In this SPARC T4-1 example, the obp-path is:
/pci@400/pci@1/pci@0/pci@4/scsi@0/disk@w5000cca00abbaeb9,0
Based on the previous table, this disk is on controller 0.
The following output example shows the obp-path for a SPARC T4-4 server.
Paths from multipath bus adapters: mpt_sas#5 (online) name=’wwn’ type=string items=1 value=’5000cca00abbaeb8’ <<=== Hard drive WWN ID name=’lun’ type=int items=1 value=00000000 name=’target-port’ type=string items=1 value=’5000cca00abbaeb9’ <<=== Hard drive SAS address name=’obp-path’ type=string items=1 value=’/pci@400/pci@1/pci@0/LSI,sas@0/disk@w5000cca00abbaeb9,0’ name=’phy-num’ type=int items=1 value=00000000 name=’path-class’ type=string items=1 value=’primary’
In this SPARC T4-4 example, the obp-path is:
/pci@400/pci@1/pci@0/pci@0/LSI,sas@0/disk@w5000cca00abbaeb9,0
Based on the previous table, this disk is on controller 0.
|