Information about errors that occurred during the exchange. Appears only if the exchange involved a StorageTek enterprise drive.
Attribute
Definition
Exchange FSC
Four-byte hexadecimal fault symptom code (FSC). For example, FD55, S053, etc. Reported only if an error occurred during the exchange.
Drive Load Limit Alert
Indicates whether the drive exceeded its lifetime limit of media loads at the time of the exchange. Possible values: Yes or No.
Media Load Limit Alert
Indicates whether the media has exceeded the recommended number of drive loads
Perm Read Errors
Number of permanent read errors
Perm Write Errors
Number of permanent write errors
Servo Perm Errors
Number of permanent servo errors
Unload Errors
Number of permanent unload errors
Usage Perm Errors
Number of unknown usage errors
Drive Dump Available
Drive dump is available
Drive Revision Down Level Alert
Drive is down-level for the media loaded
Drive Event Log Near Full
Drive event log is 75 percent or more full. This is an expected state, as the log is circular. If Oracle Service Delivery Platform (SDP) is installed, the logs are cleared.
Drive Load Alert
The media could not be loaded in the drive.
Media Snapped Alert
The media has snapped.
MIR Invalid Alert
The media directory is invalid, resulting in degraded file search performance.
Media RFID Alert
The media RFID was found to be open at load time, indicating the drive was powered off before the media was unloaded on the previous mount. Results in degraded media performance.
Media Permanent Error Alert
A permanent media error occurred while the media was mounted
Media Start of Data NOT Found
Start of customer data could not be found
Drive Meters at High Speed
Total positioning meters of media passed through the drive heads at high speed over the drive's lifetime. Positioning meters occur during locate, rewind, and spacing operations.
Drive Meters of Head Contact
Total meters of media passed through the drive heads over the drive's lifetime