Go to main content
Sun Flash Accelerator F80 PCIe Card Product Notes

Exit Print View

Updated: March 2017
 
 

SPARC Server M5-32 and M6-32 Configuration

Fifteen Sun Flash Accelerator F80 PCIe Cards are supported per SPARC M5-32 and M6-32 server physical domain. A SPARC M5-32 or M6-32 server can in+clude one to four physical domains. For example, a server with two physical domains supports 30 Sun Flash Accelerator F80 PCIe cards, fifteen in each physical domain. A server with four physical domains supports 60 cards.

The Sun Flash Accelerator F80 PCIe card requires increased cooling to remove the heat generated by the card. By the internal design of the I/O Unit (IOU), PCIe slot 8 receives less airflow than the other slots. Do not install a Sun Flash Accelerator F80 PCIe card into PCIe slot 8. Hot-plug installation of the Sun Flash Accelerator F80 PCIe card is not supported.

For more information on IOU slot priority, additional configuration options, and PCIe card installation instructions, refer to the SPARC M5-32 Server Service Manual at http://www.oracle.com/goto/M5-32/docs, and refer to SPARC M6-32 server documentation at http://www.oracle.com/goto/M6-32/docs.