Fan Speed Alarm

The following table lists the fan speed alarm.

Note:

There is one alarm for each fan on the Acme Packet 6300/6350. Each fan has its own alarm starting at SD5_FAN_UNDER_THRESHOLD_BASE, and has an offset of X where X is fan number (0-16, 5 alarms per slot and one fan on each power supply for a total of 17).

Table 6-3 Fan Speed Alarms

Alarm Name Alarm Severity Causes Example Log Message Graphic Display Window Message
SD5_FAN_UNDER_THRESHOLD_BASE+X (Where X is fan number) CRITICAL: fan speed <25%.

MINOR: fan speed <50%.

Fan failure. Fan speed: TBD

where TBD is the Revolutions per Minute (RPM) of each fan on the fan module

Fan X is at Y RPM, under critical/minor threshold of Z RPM (Where X is the fan name, Y is current speed and Z is threshold)

Note:

If this alarm occurs, the Acme Packet 6300/6350 System turns the fan speed up to the fastest possible speed.