Hardware Temperature Alarm
The following table lists the hardware temperature alarm.
Table 6-2 Hardware Temperature Alarms
| Alarm Name | Alarm Severity | Causes | Example Log Message | Graphic Display Window Message | 
| SD5_TEMPERATUR_ HIGH_MAIN | CRITICAL: >100°C MAJOR: >95°C MINOR: >90°C | Fans are obstructed or stopped. The room is abnormally hot. | Temperature: XX.XXC (where XX.XX is the temperature in degrees) | Temperature X is at Y degrees C over minor/major/critical threshold of Z (Where X is sensor name, Y is temperature and Z is threshold) | 
| SD5_TEMPERATUR_ HIGH_PHY0 | CRITICAL: >100°C MAJOR: >95°C MINOR: >90°C | Fans are obstructed or stopped. The room is abnormally hot. | Temperature: XX.XXC (where XX.XX is the temperature in degrees) | Temperature X is at Y degrees C over minor/major/critical threshold of Z (Where X is sensor name, Y is temperature and Z is threshold) | 
| SD5_TEMPERATUR_ HIGH_PHY1 | CRITICAL: >100°C MAJOR: >95°C MINOR: >90°C | Fans are obstructed or stopped. The room is abnormally hot. | Temperature: XX.XXC (where XX.XX is the temperature in degrees) | Temperature X is at Y degrees C over minor/major/critical threshold of Z (Where X is sensor name, Y is temperature and Z is threshold) | 
| SD5_TEMPERATUR_ HIGH_PHY2 | CRITICAL: >100°C MAJOR: >95°C MINOR: >90°C | Fans are obstructed or stopped. The room is abnormally hot. | Temperature: XX.XXC (where XX.XX is the temperature in degrees) | Temperature X is at Y degrees C over minor/major/critical threshold of Z (Where X is sensor name, Y is temperature and Z is threshold) | 
| SD5_TEMPERATUR_ HIGH_FLX1 | CRITICAL: >100°C MAJOR: >95°C MINOR: >90°C | Fans are obstructed or stopped. The room is abnormally hot. | Temperature: XX.XXC (where XX.XX is the temperature in degrees) | Temperature X is at Y degrees C over minor/major/critical threshold of Z (Where X is sensor name, Y is temperature and Z is threshold) | 
| SD5_TEMPERATUR_ HIGH_FLX2 | CRITICAL: >100°C MAJOR: >95°C MINOR: >90°C | Fans are obstructed or stopped. The room is abnormally hot. | Temperature: XX.XXC (where XX.XX is the temperature in degrees) | Temperature X is at Y degrees C over minor/major/critical threshold of Z (Where X is sensor name, Y is temperature and Z is threshold) | 
| SD5_TEMPERATUR_ HIGH_MGMT | CRITICAL: >100°C MAJOR: >95°C MINOR: >90°C | Fans are obstructed or stopped. The room is abnormally hot. | Temperature: XX.XXC (where XX.XX is the temperature in degrees) | Temperature X is at Y degrees C over minor/major/critical threshold of Z (Where X is sensor name, Y is temperature and Z is threshold) | 
| SD5_TEMPERATUR_ HIGH_TLS0 | CRITICAL: >100°C MAJOR: >95°C MINOR: >90°C | Fans are obstructed or stopped. The room is abnormally hot. | Temperature: XX.XXC (where XX.XX is the temperature in degrees) | Temperature X is at Y degrees C over minor/major/critical threshold of Z (Where X is sensor name, Y is temperature and Z is threshold) | 
| SD5_TEMPERATUR_ HIGH_TLS1 | CRITICAL: >100°C MAJOR: >95°C MINOR: >90°C | Fans are obstructed or stopped. The room is abnormally hot. | Temperature: XX.XXC (where XX.XX is the temperature in degrees) | Temperature X is at Y degrees C over minor/major/critical threshold of Z (Where X is sensor name, Y is temperature and Z is threshold) | 
| SD5_TEMPERATUR_ HIGH_TLS2 | CRITICAL: >100°C MAJOR: >95°C MINOR: >90°C | Fans are obstructed or stopped. The room is abnormally hot. | Temperature: XX.XXC (where XX.XX is the temperature in degrees) | Temperature X is at Y degrees C over
				minor/major/critical threshold of Z (Where X is sensor name, Y is temperature
				and Z is threshold) Note:If this alarm occurs, the Acme Packet 6300/6350 System turns the fan speed up to the fastest possible speed. | 


 