RxBindCapPcrfPoolNotMapped

Measurement Group: P-DRA Diameter Exception

Description: The number of binding capable session initiation requests that were destined for a PCRF Pool or Sub-Pool for which no PRT table was configured.

Measurement Type: Simple

Measurement Dimension: Single

Collection Interval: 5 min

Peg Condition: Each time a new binding attempt is supposed to be routed to a PCRF Pool or Sub-Pool for which no PRT table is configured at the site where the routing is occurring.

Measurement Scope: Network Element, Server Group, Resource Domain, Place, Place Association

Recovery:

  1. This measurement represents an exception condition in which a PCRF Pool or Sub-Pool has been configured for use at the NOAMP, but no PRT table has been configured at one or more sites to route requests to that PCRF Pool or Sub-Pool. Consider whether a PRT table should be configured at the Network Element to which this measurement applies
  2. Contact My Oracle Support (MOS).