Measurement Group: P-DRA Diameter Usage
Measurement Type: Simple
Measurement Dimension: Single
Description: Number of Gx RAR messages initiated by P-DRA for the purposes of querying for session existence at the policy client.
Collection Interval: 5 min
Peg Condition: The measurement shall be incremented by one each time a P-DRA DA-MP server sends a P-DRA initiated RAR request to a policy client for the purpose of querying the policy client for session existence.
Measurement Scope: All
Recovery: