Siebel Clinical Trial Management System Guide > Setting Up and Configuring Clinical Data Management System Integration > Process of Setting Up Clinical Data Management System Integration >

Setting Up the LS Clinical Integration Workflow Monitor Agent for Clinical Data Management System Integration


This topic describes how to set up the LS Clinical Integration workflow monitor agent for clinical data management system integration.

This task is a step in Process of Setting Up Clinical Data Management System Integration.

To set up the LS Clinical Integration workflow monitor agent for clinical data management system integration

  1. Navigate to the Administration - Server Configuration screen, then the Enterprises view.
  2. Navigate to the Component Definitions view, and query for Workflow*.
  3. Make a copy of the Workflow Monitor Agent component definition, and change the name to LS Clinical Integration.
  4. Change the Alias name to LSClinicalInteg.
  5. Set Component Group to Workflow Management.
  6. Under Component Parameters, query for Group Name and change the Group Name to LS Clinical Site Integration in the Component Parameter applet.
  7. Change the Action Interval to 5.
  8. Click Advanced, change the Sleep Time to 15, and change the Default Task to 1.
  9. Click Activate to change the status of the new component to Active.
  10. Synchronize the components.
  11. Restart the Siebel server.
Siebel Clinical Trial Management System Guide Copyright © 2014, Oracle and/or its affiliates. All rights reserved. Legal Notices.