30 Set Up a Flow Meter

This chapter contains these topics:

30.1 Setting Up a Flow Meter

Navigation

From Bulk Stock Management (G4150), enter 29

From Bulk Stock Management Setup (G415041), choose Meter Master Maintenance

You set up a flow meter to define such information as the current product, location, and calibration dates. The system uses this information during the throughput reconciliation process.

To set up a flow meter

On Meter Master Maintenance

Figure 30-1 Meter Master Maintenance screen

Description of Figure 30-1 follows
Description of "Figure 30-1 Meter Master Maintenance screen"

  1. Complete the following fields:

    • Branch/Plant

    • Meter Number

    • Meter Status

    • Current Product

    • Meter Units

    • Unit of Measure

  2. Complete the following optional fields or leave blank to accept the default values:

    • Date Last Calibrated

    • Throughput Since Last Calibration

    • Maximum Reading

    • Temperature Compensated

    • Load Rack Interface

  3. Complete one or both of the following optional fields:

    • Last Product

    • Date Installed

Field Explanation
Meter Number Identifies the meter number.

Form-specific information

Enter the number that identifies the meter. If you leave this field blank, the Next Number program automatically assigns the next number.

Meter Units Designates the number of meter units used to calculate the quantity that passes through the meter. Meter units can differ from the units used to calculate volume or weight. For example, one meter unit can equal three actual volumetric units.
Date Last Calibrated The last date that the meter flow was tested and calibrated. Whenever this date is changed, the system resets the entry in the Throughput Since Last Calibration field to zero.
Throughput Since Last Calibration Enter a valid number and the unit of measure in these fields. If you leave the first field blank, the system uses zero. You can enter values in these fields only during initial meter setup. After you have set up the meter, the total throughput is a rolling figure from the Meter Master table (F41506). As the system calculates volumes from closing readings, it adds them to the prior total to obtain a current figure for this record. If you change the date in the Date Last Calibrated field, the system clears this field.
Maximum Reading The largest reading on the meter before it rolls back to one. If you leave this field blank, the system uses the value assigned in the data dictionary for this field.
Temperature Compensated Indicates whether the throughput volume is already at the standard temperature. If not, a temperature conversion is required. Valid values are:

Y or 1 - Yes

N or 0 - No

Load Rack Interface Indicates whether the product is being loaded via a loading rack (gantry). Valid values are:

Y (Yes) or 1 - Loading rack interface in place

N (No) or 0 - Loading rack interface not in place


30.1.1 What You Should Know About

Topic Description
Changing current product If you want to change the current product of an existing meter, you must enter a closing meter reading for the prior product.
Attaching notes You can attach notes about the meter.