Drive Specification
Table 1 Power Requirements
|
|
|
Motor start (Surge Current, 20 sec)
|
0.600A AC
|
0.9A
|
Max I/O Conditions (Amp. rms)
|
1.300A
|
1.5A
|
|
Table 2 Physical Characteristics
|
|
|
|
0.59 in.
|
2.76 in.
|
3.95 in.
|
0.500 lb
|
14.8 ± 0.2 mm
|
70 ± 0.1 mm
|
100.3 mm ± 0.15 mm
|
0.227 kg
|
|
Note -
The physical characteristics do not include the bracket.
Table 3 Usage Information
|
|
Useful life
|
Minimum 5 years
|
Expected annualized failure rate (AFR) for normal 24/7 operating
conditions
|
0.44%
|
Normal drive temperatures
|
5 to 45 degrees Celsius
Note -
Derating of AFR applies above 45 degrees Celsius.
|
Maximum temperature
|
60 degrees Celsius
Note -
Drive may be rendered unusable above 65 degrees
Celsius.
|
Other environmental factors
|
Conforms to IEC standards
|
|
Table 4 Drive Performance
|
|
Capacity, formatted
|
1,200,243,695,616 bytes minimum (512 bytes per sector)
|
Average rotational latency
|
2.99 msec (10,000 rpm)
|
Seek times (read/write)
|
Typical
|
Single track seek
|
0.2/0.3 msec
|
Average seek
|
4.5/5.3 msec
|
Maximum seek
|
9.6/10.1 msec
|
Random 4KB reads per sec
|
Typical
|
Queue=1, 100% Volume
|
142 IOPS
|
Queue=16, 100% Volume
|
299 IOPS
|
HDA data transfer rate
|
Typical
|
Sustained sequential read
|
170 MB/sec (at ID) to 216 MB/sec (at OD)
|
Interface data transfer rate
|
12Gbps/6Gbps/3Gbps/1.5Gbps (autonegotiation, dual port, full
duplex)
|
Start/stop
|
Typical
|
Power-on to ready
|
15 sec
|
Spin down
|
15 sec
|
|