Siebel System Monitoring and Diagnostics Guide > Collecting Siebel Environment Data > Process of Collecting Siebel Environment Data Using SDDC >

Running SDDC to Collect Siebel Web Server and SWSE Data


This topic provides procedures for collecting Siebel Web Server and Siebel Web Server Extension (SWSE) data using Siebel Diagnostic Data Collector (SDDC) for Microsoft Windows and UNIX.

Running SDDC to Collect Siebel Web Server and SWSE Data for Microsoft Windows

Use the following procedure to collect Siebel Web Server and SWSE data for Microsoft Windows.

Table 56 shows the parameters available for use in collecting Siebel Web Server and SWSE data for Microsoft Windows.

Table 56. SDDC Parameters for Microsoft Windows
Parameter
Description
Required?

/g

Append this parameter to the siebsnap.exe command to collect information on the Siebel Gateway Name Server.

Yes

/s

Append this parameter to the siebsnap.exe command to collect information on the Siebel Server.

Yes

/w

Append this parameter to the siebsnap.exe command to collect information on the Web server and SWSE.

Yes

/c siebsnap.cfg

Include this parameter to reference a particular configuration file. Use this parameter if Oracle Global Customer Support provides a configuration file. For more information, see Configuring SDDC Content Under Microsoft Windows.

No

/h

Use this parameter with the siebsnap.exe command to list information on SDDC and its parameters.

No

/l

Indicates the preferred language.

No

NOTE:  Use only one of the /g, /s, and /w parameters during a single SDDC execution.

To run SDDC to collect Siebel Web Server and SWSE data for Microsoft Windows

  1. Navigate to the binary (bin) subdirectory within the SWSE_ROOT directory.
  2. Run siebsnap.exe using the /w flag and, as necessary, parameters listed in Table 56 as shown in the following example:

    siebsnap.exe /w

  3. Review the collected information in the siebsnap output directory, which is created by the SDDC utility under the SWSE_ROOT output directory.

Running SDDC to Collect Siebel Web Server and SWSE Data for UNIX

This topic provides procedures for collecting Siebel Web Server and Siebel Web Server Extension (SWSE) data using Siebel Diagnostic Data Collector (SDDC) for UNIX.

The parameters available for use in collecting Siebel Server and SWSE data for UNIX are provided in Table 57.

Table 57. SDDC Parameters for UNIX
Parameter
Description

-g siebel_gateway_name

Append the -g parameter with the name of the Siebel Gateway Name Server to collect information on the Siebel Gateway Name Server. Alternatively, use -g this_server.

-s siebel_server_name

Append the -s parameter with the name of the Siebel Server to collect information on a Siebel Server. Alternatively, use -s this_server.

-w webserver_root

Append the -w parameter with the path of the Web server root to collect information on the SWSE and Web server. Alternatively, use -w this_server.

-c siebsnap.ini

Include this parameter to reference a particular configuration INI file. For more details, see Configuring SDDC Content Under UNIX.

-help

Use this parameter with the siebsnap command to list information on SDDC and its parameters.

To run SDDC to collect Siebel Web Server and SWSE data for UNIX

  1. Do Preparing the UNIX Environment to Run SDDC.
  2. Enter the siebsnap command using the -w flag and, as necessary, parameters listed in Table 57 as shown in the following example:

    siebsnap -w webserver_root

  3. Review the collected information in the computer-name_webserver-name output directory.

NOTE:  Alternatively, use this_server in place of the Siebel Gateway Name Server name, Siebel Server name, or the Web Server name when using SDDC under UNIX.

Siebel System Monitoring and Diagnostics Guide Copyright © 2015, Oracle and/or its affiliates. All rights reserved. Legal Notices.