电源上的风扇发生故障时,会重复生成和清除故障消息,直到您更换该电源。
在 Oracle Solaris 控制台上,重复的消息如下所示:
Nov 4 09:58:41 system-name SC Alert: [ID 821027 daemon.alert] Fault critical: Fault detected at time = Tue Nov 4 14:01:16 2014. The suspect component: /SYS/PS0 has fault.chassis.device.psu.fail with probability=100.
在 Oracle ILOM 事件日志中,产生的条目如下所示:
53 Tue Nov 4 14:01:16 2014 Fault Fault critical Fault detected at time = Tue Nov 4 14:01:16 2014. The suspect component: /SYS/PS0 has fault.chassis.device.psu.fail with probability=100. 352 Tue Nov 4 14:01:06 2014 Sensor Log minor Power Supply : /SYS/PS0/STATE : Predictive failure : Asserted 351 Tue Nov 4 14:01:06 2014 Sensor Log minor Power Supply : /SYS/PS0/STATE : Failure detected : Deasserted 350 Tue Nov 4 14:01:00 2014 Fault UUID_Repaired minor Fault with UUID 9e6ba288-ec5a-48bf-d129-e24a90055231 repaired 349 Tue Nov 4 14:01:00 2014 Fault Repair minor Component /SYS/PS0 repaired 348 Tue Nov 4 14:01:00 2014 Fault Repair minor Fault fault.chassis.device.psu.fail on component /SYS/PS0 cleared 347 Tue Nov 4 14:01:00 2014 Sensor Log minor Power Supply : /SYS/PS0/STATE : Predictive failure : Deasserted 346 Tue Nov 4 14:01:00 2014 Sensor Log minor Power Supply : /SYS/PS0/STATE : Failure detected : Asserted>
解决方法:您更换故障电源后消息将停止重复。