The program description deals with the following:
The data for an OPOS lock can be updated, i.e. programmed, changed or cleared, with this program. Data which has already been stored can also be displayed for information.
Enter the number of the device under which it is to be stored in the system. The interface and the link to a processing unit should be defined and the device-specific operating mode set.
Note:
99 = zero
should be selected as device interface for all OPOS devices.
The OPOS modules must have been installed and configured if an OPOS device is to be operated.
Click on the graphic for further help with programming of OPOS Devices.
The following description deals with all available options for update of this basic data.
As with nearly all other programs the following also applies here:
Entry range permitted: alphanumeric max. 30 chars.
Note
The entry in this field is optional.
Example:
The OPOS modules are entered as follows in the registration database:
· HKEY_LOCAL_MACHINE\SOFTWARE\OLEforRetail\ ServiceOPOS\DeviceGroup\DeviceName\
The service names are listed in program regedit:
The device names can be found in the left-hand directory in the device group for the device concerned, e.g. "ADSTopCAshCentralLock".
The linked service names can be found in the right-hand directory under code "Standard" = "ADSTopCash.CentralLock.1".
Click on the graphic for further help with programming of OPOS Devices.
Entry range permitted: alphanumeric max. 30 chars.
Enter the device name of this OPOS device.
Exmple
The OPOS modules are entered as follows in the registration database:
· HKEY_LOCAL_MACHINE\SOFTWARE\OLEforRetail\ ServiceOPOS\DeviceGroup\DeviceName
The device names are listed in program regedit.
The linked device names can be found in the left-hand directory under the device group concerned.
Click on the graphic for further help with programming of OPOS Device
Entry range permitted: numeric 1 - 255
Select one of the offered debug levels by clicking onto this field and with a second click confirming the selection.
The system offers the following debug levels:
Note:
Only select a value higher than "0" for
the debug level if a protocol of communications is required for error analysis.
The details are shown in file "errlog" in directory work of
the appropriate system unit.
Field with firmly defined selection options
Select one of the offered lock types by clicking onto this field and with a second click confirming the selection.
The system offers the following lock types:
Entry range permitted: numeric 1 - 9
Default = 1
Entry range permitted: numeric 1 - 9
Default = 2
Entry range permitted: numeric 1 - 9
Default = 3
Entry range permitted: numeric 1 - 9
Default = 0
Entry range permitted: numeric 1 - 9
Default = 0
Entry range permitted: numeric 1 - 9
Default = 0
Entry range permitted: numeric 1 - 9
Default = 0
Button active: Multi threaded
is switched on
Button deactivated: Multithreaded is switched off
This option is dependent on the connected device and must be activated or deactivated accordingly.