Environment
|
-
Operating temperature: 5°C to 35°C (41°F to 95°F) at sea level; 5°C to 31°C (41°F to 88°F) at altitude
-
Non-operating temperature: -40°C to 68°C (-40°F to 154°F)
-
Operating relative humidity: 10% - 90% relative humidity, non-condensing
-
Acoustic noise: LwAd: 8.9 B (idle and operating, room temperature), 8.9 B (maximum ambient); LpAm: 75 dBA (bystander position, maximum ambient)
|
Power
|
-
AC power: 200 - 240 VAC
-
Power consumption measurements with CPUs at maximum utilization:
-
Active Idle (operating systems booted and stabilized, yet running at minimal utilization):
|
Regulations
|
-
Safety: IEC 60950, UL/CSA 60950. CB Scheme with all country differences
-
RFI/EMI: FCC CFR 47 Part 15 Class A, EN 55022 Class A, EN 61000-3-2, EN 61000-3-3, EN 300 386
-
Immunity: EN 55024, EN 300 386
|
Certifications
|
-
Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
-
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
-
Other: Complies with WEEE Directive (2002/96/EC) and RoHS Directive (2002/95/EC)
|
Physical Specifications
|
-
Weight:
For X6-4, X5-4, and X4-4: 40 kg (88 lb.) maximum
For X3-4: 44 kg (97 lb.) maximum
For X2-4: 38.5 kg (85 lb.) maximum
-
Height: 129.85 mm (5.1 in.)
-
Width: 436.5 mm (17.2 in.)
-
Depth: 732 mm (28.8 in.)
|
Mounting Option
|
|