2.5 Environmental Specifications

Table 2-6 describes the environmental specifications for the Business Intelligence Machine.

Table 2-6 Environmental Specifications for Oracle Exalytics In-Memory Machine

Component Description

Environment

  • Operating temperature: 5°C to 35°C (41°F to 95°F) at sea level; 5°C to 31°C (41°F to 88°F) at altitude

  • Non-operating temperature: -40°C to 68°C (-40°F to 154°F)

  • Operating relative humidity: 10% - 90% relative humidity, non-condensing

  • Acoustic noise: LwAd: 8.9 B (idle and operating, room temperature), 8.9 B (maximum ambient); LpAm: 75 dBA (bystander position, maximum ambient)

Power

  • AC power: 200 - 240 VAC

  • Power consumption measurements with CPUs at maximum utilization:

    • For X6-4, X5-4, and X4-4: 1600W

    • For X3-4: 1467W

    • For X2-4: 1317W

  • Active Idle (operating systems booted and stabilized, yet running at minimal utilization):

    • For X6-4, X5-4, and X4-4: 723W

    • For X3-4: 723W

    • For X2-4: 663W

Regulations

  • Safety: IEC 60950, UL/CSA 60950. CB Scheme with all country differences

  • RFI/EMI: FCC CFR 47 Part 15 Class A, EN 55022 Class A, EN 61000-3-2, EN 61000-3-3, EN 300 386

  • Immunity: EN 55024, EN 300 386

Certifications

  • Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark

  • EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A

  • Other: Complies with WEEE Directive (2002/96/EC) and RoHS Directive (2002/95/EC)

Physical Specifications

  • Weight:

    For X6-4, X5-4, and X4-4: 40 kg (88 lb.) maximum

    For X3-4: 44 kg (97 lb.) maximum

    For X2-4: 38.5 kg (85 lb.) maximum

  • Height: 129.85 mm (5.1 in.)

  • Width: 436.5 mm (17.2 in.)

  • Depth: 732 mm (28.8 in.)

Mounting Option

  • Tool-less rack-mounting slide-rail kit

  • Cable management arm

  • Two 5m InfiniBand cables