ok probe-scsi-all /pci@302/pci@2/pci@0/pci@14/LSI,sas@0 FCode Version 1.00.65, MPT Version 2.05, Firmware Version 9.00.00.00 Target 9 Unit 0 Disk HGST H101860SFSUN600G A3T0 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f0256b8 SASAddress 5000cca02f0256b9 PhyNum 0 Target a Unit 0 Disk HGST H101860SFSUN600G A3T0 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f02564c SASAddress 5000cca02f02564d PhyNum 1 Target b Unit 0 Disk HGST H101860SFSUN600G A770 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f1390f4 SASAddress 5000cca02f1390f5 PhyNum 2 Target c Unit 0 Disk HGST H101860SFSUN600G A770 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f1376d8 SASAddress 5000cca02f1376d9 PhyNum 3 Target d Unit 0 Disk HGST H101860SFSUN600G A3T0 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f027838 SASAddress 5000cca02f027839 PhyNum 4 Target e Unit 0 Disk HGST H101860SFSUN600G A3T0 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f02e798 SASAddress 5000cca02f02e799 PhyNum 5 Target f Unit 0 Disk HGST H101860SFSUN600G A3T0 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f02b138 SASAddress 5000cca02f02b139 PhyNum 6 Target 10 Unit 0 Disk HGST H101860SFSUN600G A3T0 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f028fd0 SASAddress 5000cca02f028fd1 PhyNum 7 /pci@300/pci@1/pci@0/pci@2/usb@0/storage@1 Unit 0 Disk smiMICRON eUSB DISK 1112 /pci@300/pci@1/pci@0/pci@2/usb@0/hub@2/storage@1 Unit 0 Removable Read Only device SUNRemote ISO CDROM1.01
LSI,sas@0-磁盘控制器(在本例中为 REM)。如果服务器包含多个磁盘控制器,则在该控制器信息之后将列出与每个控制器关联的目标驱动器。
SASDeviceName-Oracle Solaris 所识别的 WWN。
SASAddress-OpenBoot 引用的 WWN。
PhyNum-驱动器所占用的物理插槽(值为 0 表明驱动器位于 HDD 插槽 0 中)。
在本示例中,构造了如下名称以表明驱动器位于插槽 0 中。
cn = c0
其中,n 是 SAS 控制器编号。
tWWN = t5000cca02f0256b8
其中,WWN 是 SASDeviceName 值。
dn = d0
其中,对于所有嵌入式 SCSI 设备,n 为 0。
完整的逻辑设备名称为 c0t5000cca02f0256b8d0。